Cargando…
Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma
In this retrospective, comparative study, we evaluated and compared the performance of two confocal imaging modalities in detecting glaucoma based on a deep learning (DL) classifier: ultra-wide-field (UWF) fundus imaging and true-colour confocal scanning. A total of 777 eyes, including 273 normal co...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9181263/ https://www.ncbi.nlm.nih.gov/pubmed/35683577 http://dx.doi.org/10.3390/jcm11113168 |
_version_ | 1784723726865006592 |
---|---|
author | Shin, Younji Cho, Hyunsoo Shin, Yong Un Seong, Mincheol Choi, Jun Won Lee, Won June |
author_facet | Shin, Younji Cho, Hyunsoo Shin, Yong Un Seong, Mincheol Choi, Jun Won Lee, Won June |
author_sort | Shin, Younji |
collection | PubMed |
description | In this retrospective, comparative study, we evaluated and compared the performance of two confocal imaging modalities in detecting glaucoma based on a deep learning (DL) classifier: ultra-wide-field (UWF) fundus imaging and true-colour confocal scanning. A total of 777 eyes, including 273 normal control eyes and 504 glaucomatous eyes, were tested. A convolutional neural network was used for each true-colour confocal scan (Eidon AF™, CenterVue, Padova, Italy) and UWF fundus image (Optomap™, Optos PLC, Dunfermline, UK) to detect glaucoma. The diagnostic model was trained using 545 training and 232 test images. The presence of glaucoma was determined, and the accuracy and area under the receiver operating characteristic curve (AUC) metrics were assessed for diagnostic power comparison. DL-based UWF fundus imaging achieved an AUC of 0.904 (95% confidence interval (CI): 0.861–0.937) and accuracy of 83.62%. In contrast, DL-based true-colour confocal scanning achieved an AUC of 0.868 (95% CI: 0.824–0.912) and accuracy of 81.46%. Both DL-based confocal imaging modalities showed no significant differences in their ability to diagnose glaucoma (p = 0.135) and were comparable to the traditional optical coherence tomography parameter-based methods (all p > 0.005). Therefore, using a DL-based algorithm on true-colour confocal scanning and UWF fundus imaging, we confirmed that both confocal fundus imaging techniques had high value in diagnosing glaucoma. |
format | Online Article Text |
id | pubmed-9181263 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91812632022-06-10 Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma Shin, Younji Cho, Hyunsoo Shin, Yong Un Seong, Mincheol Choi, Jun Won Lee, Won June J Clin Med Article In this retrospective, comparative study, we evaluated and compared the performance of two confocal imaging modalities in detecting glaucoma based on a deep learning (DL) classifier: ultra-wide-field (UWF) fundus imaging and true-colour confocal scanning. A total of 777 eyes, including 273 normal control eyes and 504 glaucomatous eyes, were tested. A convolutional neural network was used for each true-colour confocal scan (Eidon AF™, CenterVue, Padova, Italy) and UWF fundus image (Optomap™, Optos PLC, Dunfermline, UK) to detect glaucoma. The diagnostic model was trained using 545 training and 232 test images. The presence of glaucoma was determined, and the accuracy and area under the receiver operating characteristic curve (AUC) metrics were assessed for diagnostic power comparison. DL-based UWF fundus imaging achieved an AUC of 0.904 (95% confidence interval (CI): 0.861–0.937) and accuracy of 83.62%. In contrast, DL-based true-colour confocal scanning achieved an AUC of 0.868 (95% CI: 0.824–0.912) and accuracy of 81.46%. Both DL-based confocal imaging modalities showed no significant differences in their ability to diagnose glaucoma (p = 0.135) and were comparable to the traditional optical coherence tomography parameter-based methods (all p > 0.005). Therefore, using a DL-based algorithm on true-colour confocal scanning and UWF fundus imaging, we confirmed that both confocal fundus imaging techniques had high value in diagnosing glaucoma. MDPI 2022-06-02 /pmc/articles/PMC9181263/ /pubmed/35683577 http://dx.doi.org/10.3390/jcm11113168 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Shin, Younji Cho, Hyunsoo Shin, Yong Un Seong, Mincheol Choi, Jun Won Lee, Won June Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma |
title | Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma |
title_full | Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma |
title_fullStr | Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma |
title_full_unstemmed | Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma |
title_short | Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma |
title_sort | comparison between deep-learning-based ultra-wide-field fundus imaging and true-colour confocal scanning for diagnosing glaucoma |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9181263/ https://www.ncbi.nlm.nih.gov/pubmed/35683577 http://dx.doi.org/10.3390/jcm11113168 |
work_keys_str_mv | AT shinyounji comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma AT chohyunsoo comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma AT shinyongun comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma AT seongmincheol comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma AT choijunwon comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma AT leewonjune comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma |