Cargando…

Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma

In this retrospective, comparative study, we evaluated and compared the performance of two confocal imaging modalities in detecting glaucoma based on a deep learning (DL) classifier: ultra-wide-field (UWF) fundus imaging and true-colour confocal scanning. A total of 777 eyes, including 273 normal co...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Younji, Cho, Hyunsoo, Shin, Yong Un, Seong, Mincheol, Choi, Jun Won, Lee, Won June
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9181263/
https://www.ncbi.nlm.nih.gov/pubmed/35683577
http://dx.doi.org/10.3390/jcm11113168
_version_ 1784723726865006592
author Shin, Younji
Cho, Hyunsoo
Shin, Yong Un
Seong, Mincheol
Choi, Jun Won
Lee, Won June
author_facet Shin, Younji
Cho, Hyunsoo
Shin, Yong Un
Seong, Mincheol
Choi, Jun Won
Lee, Won June
author_sort Shin, Younji
collection PubMed
description In this retrospective, comparative study, we evaluated and compared the performance of two confocal imaging modalities in detecting glaucoma based on a deep learning (DL) classifier: ultra-wide-field (UWF) fundus imaging and true-colour confocal scanning. A total of 777 eyes, including 273 normal control eyes and 504 glaucomatous eyes, were tested. A convolutional neural network was used for each true-colour confocal scan (Eidon AF™, CenterVue, Padova, Italy) and UWF fundus image (Optomap™, Optos PLC, Dunfermline, UK) to detect glaucoma. The diagnostic model was trained using 545 training and 232 test images. The presence of glaucoma was determined, and the accuracy and area under the receiver operating characteristic curve (AUC) metrics were assessed for diagnostic power comparison. DL-based UWF fundus imaging achieved an AUC of 0.904 (95% confidence interval (CI): 0.861–0.937) and accuracy of 83.62%. In contrast, DL-based true-colour confocal scanning achieved an AUC of 0.868 (95% CI: 0.824–0.912) and accuracy of 81.46%. Both DL-based confocal imaging modalities showed no significant differences in their ability to diagnose glaucoma (p = 0.135) and were comparable to the traditional optical coherence tomography parameter-based methods (all p > 0.005). Therefore, using a DL-based algorithm on true-colour confocal scanning and UWF fundus imaging, we confirmed that both confocal fundus imaging techniques had high value in diagnosing glaucoma.
format Online
Article
Text
id pubmed-9181263
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91812632022-06-10 Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma Shin, Younji Cho, Hyunsoo Shin, Yong Un Seong, Mincheol Choi, Jun Won Lee, Won June J Clin Med Article In this retrospective, comparative study, we evaluated and compared the performance of two confocal imaging modalities in detecting glaucoma based on a deep learning (DL) classifier: ultra-wide-field (UWF) fundus imaging and true-colour confocal scanning. A total of 777 eyes, including 273 normal control eyes and 504 glaucomatous eyes, were tested. A convolutional neural network was used for each true-colour confocal scan (Eidon AF™, CenterVue, Padova, Italy) and UWF fundus image (Optomap™, Optos PLC, Dunfermline, UK) to detect glaucoma. The diagnostic model was trained using 545 training and 232 test images. The presence of glaucoma was determined, and the accuracy and area under the receiver operating characteristic curve (AUC) metrics were assessed for diagnostic power comparison. DL-based UWF fundus imaging achieved an AUC of 0.904 (95% confidence interval (CI): 0.861–0.937) and accuracy of 83.62%. In contrast, DL-based true-colour confocal scanning achieved an AUC of 0.868 (95% CI: 0.824–0.912) and accuracy of 81.46%. Both DL-based confocal imaging modalities showed no significant differences in their ability to diagnose glaucoma (p = 0.135) and were comparable to the traditional optical coherence tomography parameter-based methods (all p > 0.005). Therefore, using a DL-based algorithm on true-colour confocal scanning and UWF fundus imaging, we confirmed that both confocal fundus imaging techniques had high value in diagnosing glaucoma. MDPI 2022-06-02 /pmc/articles/PMC9181263/ /pubmed/35683577 http://dx.doi.org/10.3390/jcm11113168 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shin, Younji
Cho, Hyunsoo
Shin, Yong Un
Seong, Mincheol
Choi, Jun Won
Lee, Won June
Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma
title Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma
title_full Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma
title_fullStr Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma
title_full_unstemmed Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma
title_short Comparison between Deep-Learning-Based Ultra-Wide-Field Fundus Imaging and True-Colour Confocal Scanning for Diagnosing Glaucoma
title_sort comparison between deep-learning-based ultra-wide-field fundus imaging and true-colour confocal scanning for diagnosing glaucoma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9181263/
https://www.ncbi.nlm.nih.gov/pubmed/35683577
http://dx.doi.org/10.3390/jcm11113168
work_keys_str_mv AT shinyounji comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma
AT chohyunsoo comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma
AT shinyongun comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma
AT seongmincheol comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma
AT choijunwon comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma
AT leewonjune comparisonbetweendeeplearningbasedultrawidefieldfundusimagingandtruecolourconfocalscanningfordiagnosingglaucoma