Cargando…

The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center

Background: In thyroid surgery, achieving accurate haemostasis is fundamental in order to avoid the occurrence of complications. Energy-based devices are currently extensively utilized in this field of surgery. This study aims to compare Harmonic Focus and Thunderbeat Open Fine Jaw with regard to su...

Descripción completa

Detalles Bibliográficos
Autores principales: Canu, Gian Luigi, Medas, Fabio, Cappellacci, Federico, Casti, Francesco, Bura, Raffaela, Erdas, Enrico, Calò, Pietro Giorgio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9181533/
https://www.ncbi.nlm.nih.gov/pubmed/35683450
http://dx.doi.org/10.3390/jcm11113062
_version_ 1784723798610673664
author Canu, Gian Luigi
Medas, Fabio
Cappellacci, Federico
Casti, Francesco
Bura, Raffaela
Erdas, Enrico
Calò, Pietro Giorgio
author_facet Canu, Gian Luigi
Medas, Fabio
Cappellacci, Federico
Casti, Francesco
Bura, Raffaela
Erdas, Enrico
Calò, Pietro Giorgio
author_sort Canu, Gian Luigi
collection PubMed
description Background: In thyroid surgery, achieving accurate haemostasis is fundamental in order to avoid the occurrence of complications. Energy-based devices are currently extensively utilized in this field of surgery. This study aims to compare Harmonic Focus and Thunderbeat Open Fine Jaw with regard to surgical outcomes and complications. Methods: Patients submitted to total thyroidectomy in our center, between January 2017 and June 2020, were retrospectively analysed. Based on the energy-based device utilized, two groups were identified: Group A (Harmonic Focus) and Group B (Thunderbeat Open Fine Jaw). Results: A total of 527 patients were included: 409 in Group A and 118 in Group B. About surgical outcomes, the mean operative time was significantly shorter in Group B than in Group A (p < 0.001), while as regards complications, the occurrence of transient recurrent laryngeal nerve injury was significantly greater in Group B than in Group A (p = 0.019). Conclusions. Both Harmonic Focus and Thunderbeat Open Fine Jaw have proven to be effective devices. Operative times were significantly shorter in thyroidectomies performed with Thunderbeat Open Fine Jaw; however, the occurrence of transient recurrent laryngeal nerve injury was significantly greater in patients operated on with this device.
format Online
Article
Text
id pubmed-9181533
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91815332022-06-10 The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center Canu, Gian Luigi Medas, Fabio Cappellacci, Federico Casti, Francesco Bura, Raffaela Erdas, Enrico Calò, Pietro Giorgio J Clin Med Article Background: In thyroid surgery, achieving accurate haemostasis is fundamental in order to avoid the occurrence of complications. Energy-based devices are currently extensively utilized in this field of surgery. This study aims to compare Harmonic Focus and Thunderbeat Open Fine Jaw with regard to surgical outcomes and complications. Methods: Patients submitted to total thyroidectomy in our center, between January 2017 and June 2020, were retrospectively analysed. Based on the energy-based device utilized, two groups were identified: Group A (Harmonic Focus) and Group B (Thunderbeat Open Fine Jaw). Results: A total of 527 patients were included: 409 in Group A and 118 in Group B. About surgical outcomes, the mean operative time was significantly shorter in Group B than in Group A (p < 0.001), while as regards complications, the occurrence of transient recurrent laryngeal nerve injury was significantly greater in Group B than in Group A (p = 0.019). Conclusions. Both Harmonic Focus and Thunderbeat Open Fine Jaw have proven to be effective devices. Operative times were significantly shorter in thyroidectomies performed with Thunderbeat Open Fine Jaw; however, the occurrence of transient recurrent laryngeal nerve injury was significantly greater in patients operated on with this device. MDPI 2022-05-29 /pmc/articles/PMC9181533/ /pubmed/35683450 http://dx.doi.org/10.3390/jcm11113062 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Canu, Gian Luigi
Medas, Fabio
Cappellacci, Federico
Casti, Francesco
Bura, Raffaela
Erdas, Enrico
Calò, Pietro Giorgio
The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center
title The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center
title_full The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center
title_fullStr The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center
title_full_unstemmed The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center
title_short The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center
title_sort use of harmonic focus and thunderbeat open fine jaw in thyroid surgery: experience of a high-volume center
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9181533/
https://www.ncbi.nlm.nih.gov/pubmed/35683450
http://dx.doi.org/10.3390/jcm11113062
work_keys_str_mv AT canugianluigi theuseofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT medasfabio theuseofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT cappellaccifederico theuseofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT castifrancesco theuseofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT buraraffaela theuseofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT erdasenrico theuseofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT calopietrogiorgio theuseofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT canugianluigi useofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT medasfabio useofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT cappellaccifederico useofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT castifrancesco useofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT buraraffaela useofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT erdasenrico useofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter
AT calopietrogiorgio useofharmonicfocusandthunderbeatopenfinejawinthyroidsurgeryexperienceofahighvolumecenter