Cargando…
HPLC Determination of Colistin in Human Urine Using Alkaline Mobile Phase Combined with Post-Column Derivatization: Validation Using Accuracy Profiles
In this study, the development, validation, and application of a new liquid chromatography post-column derivatization method for the determination of Colistin in human urine samples is demonstrated. Separation of Colistin was performed using a core–shell C(18) analytical column in an alkaline medium...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9181871/ https://www.ncbi.nlm.nih.gov/pubmed/35684427 http://dx.doi.org/10.3390/molecules27113489 |
_version_ | 1784723891758825472 |
---|---|
author | Papavasileiou, Kalliopi Tsiasioti, Apostolia Tzanavaras, Paraskevas D. Zacharis, Constantinos K. |
author_facet | Papavasileiou, Kalliopi Tsiasioti, Apostolia Tzanavaras, Paraskevas D. Zacharis, Constantinos K. |
author_sort | Papavasileiou, Kalliopi |
collection | PubMed |
description | In this study, the development, validation, and application of a new liquid chromatography post-column derivatization method for the determination of Colistin in human urine samples is demonstrated. Separation of Colistin was performed using a core–shell C(18) analytical column in an alkaline medium in order (i) to be compatible with the o-phthalaldehyde-based post-column derivatization reaction and (ii) to obtain better retention of the analyte. The Colistin derivative was detected spectrofluorometrically (λ(ext)/λ(em) = 340/460 nm) after post-column derivatization with o-phthalaldehyde and N-acetyl cysteine. The post-column derivatization parameters were optimized using the Box–Behnken experimental design, and the method was validated using the total error concept. The β-expectation tolerance intervals did not exceed the acceptance criteria of ±15%, meaning that 95% of future results would be included in the defined bias limits. The limit of detection of the method was adequate corresponding to 100 nmol·L(−1). The mean analytical bias (expressed as relative error) in the spiking levels was suitable, being in the range of −2.8 to +2.5% for both compounds with the percentage relative standard deviation lower than 3.4% in all cases. The proposed analytical method was satisfactorily applied to the analysis of the drug in human urine samples. |
format | Online Article Text |
id | pubmed-9181871 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91818712022-06-10 HPLC Determination of Colistin in Human Urine Using Alkaline Mobile Phase Combined with Post-Column Derivatization: Validation Using Accuracy Profiles Papavasileiou, Kalliopi Tsiasioti, Apostolia Tzanavaras, Paraskevas D. Zacharis, Constantinos K. Molecules Article In this study, the development, validation, and application of a new liquid chromatography post-column derivatization method for the determination of Colistin in human urine samples is demonstrated. Separation of Colistin was performed using a core–shell C(18) analytical column in an alkaline medium in order (i) to be compatible with the o-phthalaldehyde-based post-column derivatization reaction and (ii) to obtain better retention of the analyte. The Colistin derivative was detected spectrofluorometrically (λ(ext)/λ(em) = 340/460 nm) after post-column derivatization with o-phthalaldehyde and N-acetyl cysteine. The post-column derivatization parameters were optimized using the Box–Behnken experimental design, and the method was validated using the total error concept. The β-expectation tolerance intervals did not exceed the acceptance criteria of ±15%, meaning that 95% of future results would be included in the defined bias limits. The limit of detection of the method was adequate corresponding to 100 nmol·L(−1). The mean analytical bias (expressed as relative error) in the spiking levels was suitable, being in the range of −2.8 to +2.5% for both compounds with the percentage relative standard deviation lower than 3.4% in all cases. The proposed analytical method was satisfactorily applied to the analysis of the drug in human urine samples. MDPI 2022-05-28 /pmc/articles/PMC9181871/ /pubmed/35684427 http://dx.doi.org/10.3390/molecules27113489 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Papavasileiou, Kalliopi Tsiasioti, Apostolia Tzanavaras, Paraskevas D. Zacharis, Constantinos K. HPLC Determination of Colistin in Human Urine Using Alkaline Mobile Phase Combined with Post-Column Derivatization: Validation Using Accuracy Profiles |
title | HPLC Determination of Colistin in Human Urine Using Alkaline Mobile Phase Combined with Post-Column Derivatization: Validation Using Accuracy Profiles |
title_full | HPLC Determination of Colistin in Human Urine Using Alkaline Mobile Phase Combined with Post-Column Derivatization: Validation Using Accuracy Profiles |
title_fullStr | HPLC Determination of Colistin in Human Urine Using Alkaline Mobile Phase Combined with Post-Column Derivatization: Validation Using Accuracy Profiles |
title_full_unstemmed | HPLC Determination of Colistin in Human Urine Using Alkaline Mobile Phase Combined with Post-Column Derivatization: Validation Using Accuracy Profiles |
title_short | HPLC Determination of Colistin in Human Urine Using Alkaline Mobile Phase Combined with Post-Column Derivatization: Validation Using Accuracy Profiles |
title_sort | hplc determination of colistin in human urine using alkaline mobile phase combined with post-column derivatization: validation using accuracy profiles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9181871/ https://www.ncbi.nlm.nih.gov/pubmed/35684427 http://dx.doi.org/10.3390/molecules27113489 |
work_keys_str_mv | AT papavasileioukalliopi hplcdeterminationofcolistininhumanurineusingalkalinemobilephasecombinedwithpostcolumnderivatizationvalidationusingaccuracyprofiles AT tsiasiotiapostolia hplcdeterminationofcolistininhumanurineusingalkalinemobilephasecombinedwithpostcolumnderivatizationvalidationusingaccuracyprofiles AT tzanavarasparaskevasd hplcdeterminationofcolistininhumanurineusingalkalinemobilephasecombinedwithpostcolumnderivatizationvalidationusingaccuracyprofiles AT zacharisconstantinosk hplcdeterminationofcolistininhumanurineusingalkalinemobilephasecombinedwithpostcolumnderivatizationvalidationusingaccuracyprofiles |