Time-Correction Model Based on Diverter Speed for a pVTt Gas Flow Primary Standard

The volumetric primary standard with a constant volume (pVTt) determines the flow rate from the rate of change of gas density in the defined measuring volume. The key element of the measuring system that uses the flying start–stop method is a diverter. This paper presents a time correction model tha...

Descripción completa

Detalles Bibliográficos
Autores principales: Žibret, Primož, Bobovnik, Gregor, Kutin, Jože
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9182970/
https://www.ncbi.nlm.nih.gov/pubmed/35684623
http://dx.doi.org/10.3390/s22114001
_version_ 1784724171723374592
author Žibret, Primož
Bobovnik, Gregor
Kutin, Jože
author_facet Žibret, Primož
Bobovnik, Gregor
Kutin, Jože
author_sort Žibret, Primož
collection PubMed
description The volumetric primary standard with a constant volume (pVTt) determines the flow rate from the rate of change of gas density in the defined measuring volume. The key element of the measuring system that uses the flying start–stop method is a diverter. This paper presents a time correction model that adapts the correction according to the diverting speed implemented in our pVTt system developed for flow rates smaller than [Formula: see text]. A detailed study of the diverter’s effects on the effective collection time and two methods for determining the time correction are presented. One is based on the ISO 4185 standard and the other on measurements of the dynamic pressure upstream of the diverter. A set of correction time measurements were made at different diversion speeds to define the correction model at a flow rate of [Formula: see text]. The results show very good agreement between the measurements with both methods and the defined correction model. Additional measurements were made at smaller flow rates and the results indicate the independence of the time correction from the measured flow rate.
format Online
Article
Text
id pubmed-9182970
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91829702022-06-10 Time-Correction Model Based on Diverter Speed for a pVTt Gas Flow Primary Standard Žibret, Primož Bobovnik, Gregor Kutin, Jože Sensors (Basel) Article The volumetric primary standard with a constant volume (pVTt) determines the flow rate from the rate of change of gas density in the defined measuring volume. The key element of the measuring system that uses the flying start–stop method is a diverter. This paper presents a time correction model that adapts the correction according to the diverting speed implemented in our pVTt system developed for flow rates smaller than [Formula: see text]. A detailed study of the diverter’s effects on the effective collection time and two methods for determining the time correction are presented. One is based on the ISO 4185 standard and the other on measurements of the dynamic pressure upstream of the diverter. A set of correction time measurements were made at different diversion speeds to define the correction model at a flow rate of [Formula: see text]. The results show very good agreement between the measurements with both methods and the defined correction model. Additional measurements were made at smaller flow rates and the results indicate the independence of the time correction from the measured flow rate. MDPI 2022-05-25 /pmc/articles/PMC9182970/ /pubmed/35684623 http://dx.doi.org/10.3390/s22114001 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Žibret, Primož
Bobovnik, Gregor
Kutin, Jože
Time-Correction Model Based on Diverter Speed for a pVTt Gas Flow Primary Standard
title Time-Correction Model Based on Diverter Speed for a pVTt Gas Flow Primary Standard
title_full Time-Correction Model Based on Diverter Speed for a pVTt Gas Flow Primary Standard
title_fullStr Time-Correction Model Based on Diverter Speed for a pVTt Gas Flow Primary Standard
title_full_unstemmed Time-Correction Model Based on Diverter Speed for a pVTt Gas Flow Primary Standard
title_short Time-Correction Model Based on Diverter Speed for a pVTt Gas Flow Primary Standard
title_sort time-correction model based on diverter speed for a pvtt gas flow primary standard
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9182970/
https://www.ncbi.nlm.nih.gov/pubmed/35684623
http://dx.doi.org/10.3390/s22114001
work_keys_str_mv AT zibretprimoz timecorrectionmodelbasedondiverterspeedforapvttgasflowprimarystandard
AT bobovnikgregor timecorrectionmodelbasedondiverterspeedforapvttgasflowprimarystandard
AT kutinjoze timecorrectionmodelbasedondiverterspeedforapvttgasflowprimarystandard