Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas

Painless, cuffless and continuous blood pressure monitoring sensors provide a more dynamic measure of blood pressure for critical diagnosis or continuous monitoring of hypertensive patients compared to current cuff-based options. To this end, a novel flexible, wearable and miniaturized microstrip pa...

Descripción completa

Detalles Bibliográficos
Autores principales: El Abbasi, Mona K., Madi, Mervat, Jelinek, Herbert F., Kabalan, Karim Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9183053/
https://www.ncbi.nlm.nih.gov/pubmed/35684617
http://dx.doi.org/10.3390/s22113996
_version_ 1784724194401976320
author El Abbasi, Mona K.
Madi, Mervat
Jelinek, Herbert F.
Kabalan, Karim Y.
author_facet El Abbasi, Mona K.
Madi, Mervat
Jelinek, Herbert F.
Kabalan, Karim Y.
author_sort El Abbasi, Mona K.
collection PubMed
description Painless, cuffless and continuous blood pressure monitoring sensors provide a more dynamic measure of blood pressure for critical diagnosis or continuous monitoring of hypertensive patients compared to current cuff-based options. To this end, a novel flexible, wearable and miniaturized microstrip patch antenna topology is proposed to measure dynamic blood pressure (BP). The methodology was implemented on a simulated five-layer human tissue arm model created and designed in High-Frequency Simulation Software “HFSS”. The electrical properties of the five-layer human tissue were set at the frequency range (2–3) GHz to comply with clinical/engineering standards. The fabricated patch incorporated on a 0.4 mm epoxy substrate achieved consistency between the simulated and measured reflection coefficient results at flat and bent conditions over the frequency range of 2.3–2.6 GHz. Simulations for a 10 g average specific absorption rate (SAR) based on IEEE-Standard for a human arm at different input powers were also carried out. The safest input power was 50 mW with an acceptable SAR value of 3.89 W/Kg < 4W/Kg. This study also explored a novel method to obtain the pulse transit time (PTT) as an option to measure BP. Pulse transmit time is based on obtaining the time difference between the transmission coefficient scattering waveforms measured between the two pairs of metallic sensors underlying the assumption that brachial arterial geometries are dynamic. Consequently, the proposed model is validated by comparing it to the standard nonlinear Moens and Korteweg model over different artery thickness-radius ratios, showing excellent correlation between 0.76 ± 0.03 and 0.81 ± 0.03 with the systolic and diastolic BP results. The absolute risk of arterial blood pressure increased with the increase in brachial artery thickness-radius ratio. The results of both methods successfully demonstrate how the radius estimates, PTT and pulse wave velocity (PWV), along with electromagnetic (EM) antenna transmission propagation characteristics, can be used to estimate continuous BP non-invasively.
format Online
Article
Text
id pubmed-9183053
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91830532022-06-10 Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas El Abbasi, Mona K. Madi, Mervat Jelinek, Herbert F. Kabalan, Karim Y. Sensors (Basel) Article Painless, cuffless and continuous blood pressure monitoring sensors provide a more dynamic measure of blood pressure for critical diagnosis or continuous monitoring of hypertensive patients compared to current cuff-based options. To this end, a novel flexible, wearable and miniaturized microstrip patch antenna topology is proposed to measure dynamic blood pressure (BP). The methodology was implemented on a simulated five-layer human tissue arm model created and designed in High-Frequency Simulation Software “HFSS”. The electrical properties of the five-layer human tissue were set at the frequency range (2–3) GHz to comply with clinical/engineering standards. The fabricated patch incorporated on a 0.4 mm epoxy substrate achieved consistency between the simulated and measured reflection coefficient results at flat and bent conditions over the frequency range of 2.3–2.6 GHz. Simulations for a 10 g average specific absorption rate (SAR) based on IEEE-Standard for a human arm at different input powers were also carried out. The safest input power was 50 mW with an acceptable SAR value of 3.89 W/Kg < 4W/Kg. This study also explored a novel method to obtain the pulse transit time (PTT) as an option to measure BP. Pulse transmit time is based on obtaining the time difference between the transmission coefficient scattering waveforms measured between the two pairs of metallic sensors underlying the assumption that brachial arterial geometries are dynamic. Consequently, the proposed model is validated by comparing it to the standard nonlinear Moens and Korteweg model over different artery thickness-radius ratios, showing excellent correlation between 0.76 ± 0.03 and 0.81 ± 0.03 with the systolic and diastolic BP results. The absolute risk of arterial blood pressure increased with the increase in brachial artery thickness-radius ratio. The results of both methods successfully demonstrate how the radius estimates, PTT and pulse wave velocity (PWV), along with electromagnetic (EM) antenna transmission propagation characteristics, can be used to estimate continuous BP non-invasively. MDPI 2022-05-25 /pmc/articles/PMC9183053/ /pubmed/35684617 http://dx.doi.org/10.3390/s22113996 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
El Abbasi, Mona K.
Madi, Mervat
Jelinek, Herbert F.
Kabalan, Karim Y.
Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas
title Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas
title_full Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas
title_fullStr Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas
title_full_unstemmed Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas
title_short Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas
title_sort wearable blood pressure sensing based on transmission coefficient scattering for microstrip patch antennas
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9183053/
https://www.ncbi.nlm.nih.gov/pubmed/35684617
http://dx.doi.org/10.3390/s22113996
work_keys_str_mv AT elabbasimonak wearablebloodpressuresensingbasedontransmissioncoefficientscatteringformicrostrippatchantennas
AT madimervat wearablebloodpressuresensingbasedontransmissioncoefficientscatteringformicrostrippatchantennas
AT jelinekherbertf wearablebloodpressuresensingbasedontransmissioncoefficientscatteringformicrostrippatchantennas
AT kabalankarimy wearablebloodpressuresensingbasedontransmissioncoefficientscatteringformicrostrippatchantennas