Cargando…

The classification of gastric antral vascular ectasia in cirrhotic patients by Versatile Intelligent Staining Technology

BACKGROUND: Portal hypertensive gastropathy (PHG) and gastric antral vascular ectasia (GAVE) are two different pathologies that cause bleeding in cirrhotic patients. These two pathologies are still difficult to be distinguished by white light endoscopy (conventional), as they both appear as red spot...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdelmoneim, Randa Salah Eldin, Abdelmoety, Amr Aly, Baddour, Nahed, Salem, Perihan, Metawea, Marwa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9184394/
https://www.ncbi.nlm.nih.gov/pubmed/35702616
http://dx.doi.org/10.1186/s43066-022-00198-9
Descripción
Sumario:BACKGROUND: Portal hypertensive gastropathy (PHG) and gastric antral vascular ectasia (GAVE) are two different pathologies that cause bleeding in cirrhotic patients. These two pathologies are still difficult to be distinguished by white light endoscopy (conventional), as they both appear as red spots in the gastric antral mucosa in the case of severe PHG. The aim of our study was to assess the efficacy of Versatile Intelligent Staining Technology (VIST) in comparison to histopathology in the diagnosis and classification of GAVE. METHODS: A cross-sectional study included 50 patients with liver cirrhosis recruited from Alexandria Main University Hospital. Patients with connective tissue diseases and chronic kidney disease were excluded. All patients were examined by both conventional white light endoscopy (WLE) and image enhancement technology (VIST) using Sonoscape HD500 endoscope. GAVE was diagnosed as tortuous columns of ectatic vessels in the gastric antrum. Histopathological examination was used as the standard tool for the diagnosis of GAVE. RESULTS: A total of 50 patients were included, 28 patients (56 %) were diagnosed as GAVE by pathology vs 22 (44 %) as non-GAVE. Twenty-three of 28 (78.6 %) cases of GAVE were detected by VIST. VIST had superior sensitivity than WLE in the detection of GAVE, 82.1 % vs 7.1 %, while WLE had higher specificity 95.5 % vs 59.1 % by VIST. There was statistical significance between VIST and pathology in the diagnosis of GAVE, p<0.035, but no statistical significance between WLE and pathology. VIST has identified two types of GAVE: focal in 12/28 cases and diffuse in 11/28, and five were not diagnosed by VIST. CONCLUSIONS: Versatile Intelligent Staining Technology could be used as an alternative tool to histopathological diagnosis of GAVE. GAVE can present as a focal group of ectatic vessels which adds a new class to GAVE classification that was previously misdiagnosed.