Cargando…

Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging

The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils...

Descripción completa

Detalles Bibliográficos
Autores principales: Seo, Jeung-Hoon, Ryu, Yeunchul, Chung, Jun-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185248/
https://www.ncbi.nlm.nih.gov/pubmed/35684895
http://dx.doi.org/10.3390/s22114274
_version_ 1784724677049974784
author Seo, Jeung-Hoon
Ryu, Yeunchul
Chung, Jun-Young
author_facet Seo, Jeung-Hoon
Ryu, Yeunchul
Chung, Jun-Young
author_sort Seo, Jeung-Hoon
collection PubMed
description The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils used in electromagnetic field simulations were configured to operate in transmission/reception mode at a frequency of 9.4 T–400 MHz. Computational analysis using the finite-difference time-domain method was used to assess the single-channel surface RF coil by comparing single-channel surface RF coils of varying sizes in terms of |B(1)|-, |B(1)(+)|-, |B(1)(−)|- and |E|-field distribution. RF safety for the prevention of burn injuries to small animals was assessed using an analysis of the specific absorption rate. A single-channel surface RF coil with a 20 mm diameter provided optimal B(1)-field distribution and RF safety, thus confirming that single-channel surface RF coils with ≥25 mm diameter could not provide typical B(1)-field distribution. A single-channel surface RF coil with a 20 mm diameter for mouse body imaging at 9.4 T MRI was recommended to preserve the characteristics of single-channel surface RF coils, and ensured that RF signals were applied correctly to the target point within RF safety guidelines.
format Online
Article
Text
id pubmed-9185248
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91852482022-06-11 Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging Seo, Jeung-Hoon Ryu, Yeunchul Chung, Jun-Young Sensors (Basel) Article The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils used in electromagnetic field simulations were configured to operate in transmission/reception mode at a frequency of 9.4 T–400 MHz. Computational analysis using the finite-difference time-domain method was used to assess the single-channel surface RF coil by comparing single-channel surface RF coils of varying sizes in terms of |B(1)|-, |B(1)(+)|-, |B(1)(−)|- and |E|-field distribution. RF safety for the prevention of burn injuries to small animals was assessed using an analysis of the specific absorption rate. A single-channel surface RF coil with a 20 mm diameter provided optimal B(1)-field distribution and RF safety, thus confirming that single-channel surface RF coils with ≥25 mm diameter could not provide typical B(1)-field distribution. A single-channel surface RF coil with a 20 mm diameter for mouse body imaging at 9.4 T MRI was recommended to preserve the characteristics of single-channel surface RF coils, and ensured that RF signals were applied correctly to the target point within RF safety guidelines. MDPI 2022-06-03 /pmc/articles/PMC9185248/ /pubmed/35684895 http://dx.doi.org/10.3390/s22114274 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Seo, Jeung-Hoon
Ryu, Yeunchul
Chung, Jun-Young
Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging
title Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging
title_full Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging
title_fullStr Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging
title_full_unstemmed Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging
title_short Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging
title_sort simulation study of radio frequency safety and the optimal size of a single-channel surface radio frequency coil for mice at 9.4 t magnetic resonance imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185248/
https://www.ncbi.nlm.nih.gov/pubmed/35684895
http://dx.doi.org/10.3390/s22114274
work_keys_str_mv AT seojeunghoon simulationstudyofradiofrequencysafetyandtheoptimalsizeofasinglechannelsurfaceradiofrequencycoilformiceat94tmagneticresonanceimaging
AT ryuyeunchul simulationstudyofradiofrequencysafetyandtheoptimalsizeofasinglechannelsurfaceradiofrequencycoilformiceat94tmagneticresonanceimaging
AT chungjunyoung simulationstudyofradiofrequencysafetyandtheoptimalsizeofasinglechannelsurfaceradiofrequencycoilformiceat94tmagneticresonanceimaging