Cargando…
Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging
The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185248/ https://www.ncbi.nlm.nih.gov/pubmed/35684895 http://dx.doi.org/10.3390/s22114274 |
_version_ | 1784724677049974784 |
---|---|
author | Seo, Jeung-Hoon Ryu, Yeunchul Chung, Jun-Young |
author_facet | Seo, Jeung-Hoon Ryu, Yeunchul Chung, Jun-Young |
author_sort | Seo, Jeung-Hoon |
collection | PubMed |
description | The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils used in electromagnetic field simulations were configured to operate in transmission/reception mode at a frequency of 9.4 T–400 MHz. Computational analysis using the finite-difference time-domain method was used to assess the single-channel surface RF coil by comparing single-channel surface RF coils of varying sizes in terms of |B(1)|-, |B(1)(+)|-, |B(1)(−)|- and |E|-field distribution. RF safety for the prevention of burn injuries to small animals was assessed using an analysis of the specific absorption rate. A single-channel surface RF coil with a 20 mm diameter provided optimal B(1)-field distribution and RF safety, thus confirming that single-channel surface RF coils with ≥25 mm diameter could not provide typical B(1)-field distribution. A single-channel surface RF coil with a 20 mm diameter for mouse body imaging at 9.4 T MRI was recommended to preserve the characteristics of single-channel surface RF coils, and ensured that RF signals were applied correctly to the target point within RF safety guidelines. |
format | Online Article Text |
id | pubmed-9185248 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-91852482022-06-11 Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging Seo, Jeung-Hoon Ryu, Yeunchul Chung, Jun-Young Sensors (Basel) Article The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils used in electromagnetic field simulations were configured to operate in transmission/reception mode at a frequency of 9.4 T–400 MHz. Computational analysis using the finite-difference time-domain method was used to assess the single-channel surface RF coil by comparing single-channel surface RF coils of varying sizes in terms of |B(1)|-, |B(1)(+)|-, |B(1)(−)|- and |E|-field distribution. RF safety for the prevention of burn injuries to small animals was assessed using an analysis of the specific absorption rate. A single-channel surface RF coil with a 20 mm diameter provided optimal B(1)-field distribution and RF safety, thus confirming that single-channel surface RF coils with ≥25 mm diameter could not provide typical B(1)-field distribution. A single-channel surface RF coil with a 20 mm diameter for mouse body imaging at 9.4 T MRI was recommended to preserve the characteristics of single-channel surface RF coils, and ensured that RF signals were applied correctly to the target point within RF safety guidelines. MDPI 2022-06-03 /pmc/articles/PMC9185248/ /pubmed/35684895 http://dx.doi.org/10.3390/s22114274 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Seo, Jeung-Hoon Ryu, Yeunchul Chung, Jun-Young Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging |
title | Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging |
title_full | Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging |
title_fullStr | Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging |
title_full_unstemmed | Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging |
title_short | Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging |
title_sort | simulation study of radio frequency safety and the optimal size of a single-channel surface radio frequency coil for mice at 9.4 t magnetic resonance imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185248/ https://www.ncbi.nlm.nih.gov/pubmed/35684895 http://dx.doi.org/10.3390/s22114274 |
work_keys_str_mv | AT seojeunghoon simulationstudyofradiofrequencysafetyandtheoptimalsizeofasinglechannelsurfaceradiofrequencycoilformiceat94tmagneticresonanceimaging AT ryuyeunchul simulationstudyofradiofrequencysafetyandtheoptimalsizeofasinglechannelsurfaceradiofrequencycoilformiceat94tmagneticresonanceimaging AT chungjunyoung simulationstudyofradiofrequencysafetyandtheoptimalsizeofasinglechannelsurfaceradiofrequencycoilformiceat94tmagneticresonanceimaging |