Cargando…

Sensitivity Improvement of Multi-Slot Subwavelength Bragg Grating Refractive Index Sensors by Increasing the Waveguide Height or Suspending the Sensor

We present two methods of improving wavelength sensitivity for multi-slot sub-wavelength Bragg grating (MS-SW BG) refractive index sensors. The sensor structure is designed to have high optical mode confinement in the gaps between the silicon pillars whereby the surrounding medium interaction is hig...

Descripción completa

Detalles Bibliográficos
Autores principales: Heinsalu, Siim, Utaka, Katsuyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185276/
https://www.ncbi.nlm.nih.gov/pubmed/35684757
http://dx.doi.org/10.3390/s22114136
_version_ 1784724684471795712
author Heinsalu, Siim
Utaka, Katsuyuki
author_facet Heinsalu, Siim
Utaka, Katsuyuki
author_sort Heinsalu, Siim
collection PubMed
description We present two methods of improving wavelength sensitivity for multi-slot sub-wavelength Bragg grating (MS-SW BG) refractive index sensors. The sensor structure is designed to have high optical mode confinement in the gaps between the silicon pillars whereby the surrounding medium interaction is high, thus improving the sensitivity. Further sensitivity improvements are achieved by increasing the waveguide height or suspending the sensor. The second option, sensor suspension, additionally requires supporting modifications in which case various configurations are considered. After the optimization of the parameters the sensors were fabricated. For the case of a waveguide height increase to 500 nm, the sensitivity of 850 nm/RIU was obtained; for sensor suspension with fully etched holes, 922 nm/RIU; for the case of not fully etched holes, 1100 nm/RIU; with the sensor lengths of about 10 µm for all cases. These values show improvements by 16.5%, 25%, and 50.5%, respectively, compared to the previous result where the height was fixed to 340 nm.
format Online
Article
Text
id pubmed-9185276
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-91852762022-06-11 Sensitivity Improvement of Multi-Slot Subwavelength Bragg Grating Refractive Index Sensors by Increasing the Waveguide Height or Suspending the Sensor Heinsalu, Siim Utaka, Katsuyuki Sensors (Basel) Article We present two methods of improving wavelength sensitivity for multi-slot sub-wavelength Bragg grating (MS-SW BG) refractive index sensors. The sensor structure is designed to have high optical mode confinement in the gaps between the silicon pillars whereby the surrounding medium interaction is high, thus improving the sensitivity. Further sensitivity improvements are achieved by increasing the waveguide height or suspending the sensor. The second option, sensor suspension, additionally requires supporting modifications in which case various configurations are considered. After the optimization of the parameters the sensors were fabricated. For the case of a waveguide height increase to 500 nm, the sensitivity of 850 nm/RIU was obtained; for sensor suspension with fully etched holes, 922 nm/RIU; for the case of not fully etched holes, 1100 nm/RIU; with the sensor lengths of about 10 µm for all cases. These values show improvements by 16.5%, 25%, and 50.5%, respectively, compared to the previous result where the height was fixed to 340 nm. MDPI 2022-05-29 /pmc/articles/PMC9185276/ /pubmed/35684757 http://dx.doi.org/10.3390/s22114136 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Heinsalu, Siim
Utaka, Katsuyuki
Sensitivity Improvement of Multi-Slot Subwavelength Bragg Grating Refractive Index Sensors by Increasing the Waveguide Height or Suspending the Sensor
title Sensitivity Improvement of Multi-Slot Subwavelength Bragg Grating Refractive Index Sensors by Increasing the Waveguide Height or Suspending the Sensor
title_full Sensitivity Improvement of Multi-Slot Subwavelength Bragg Grating Refractive Index Sensors by Increasing the Waveguide Height or Suspending the Sensor
title_fullStr Sensitivity Improvement of Multi-Slot Subwavelength Bragg Grating Refractive Index Sensors by Increasing the Waveguide Height or Suspending the Sensor
title_full_unstemmed Sensitivity Improvement of Multi-Slot Subwavelength Bragg Grating Refractive Index Sensors by Increasing the Waveguide Height or Suspending the Sensor
title_short Sensitivity Improvement of Multi-Slot Subwavelength Bragg Grating Refractive Index Sensors by Increasing the Waveguide Height or Suspending the Sensor
title_sort sensitivity improvement of multi-slot subwavelength bragg grating refractive index sensors by increasing the waveguide height or suspending the sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185276/
https://www.ncbi.nlm.nih.gov/pubmed/35684757
http://dx.doi.org/10.3390/s22114136
work_keys_str_mv AT heinsalusiim sensitivityimprovementofmultislotsubwavelengthbragggratingrefractiveindexsensorsbyincreasingthewaveguideheightorsuspendingthesensor
AT utakakatsuyuki sensitivityimprovementofmultislotsubwavelengthbragggratingrefractiveindexsensorsbyincreasingthewaveguideheightorsuspendingthesensor