Cargando…

Carbon monoxide: raising awareness of the silent killer in the emergency department

BACKGROUND: Carbon monoxide (CO) is an odourless gas produced by the incomplete combustion of carbon containing materials. CO poisoning causes a range of symptoms of which headache is the most common, occurring in up to 90% of patients. An audit in the Emergency Department at University Hospital Ain...

Descripción completa

Detalles Bibliográficos
Autores principales: Malik, Fahad Siddique, Ghazal Asswad, Randa, Clarke, Simon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185569/
https://www.ncbi.nlm.nih.gov/pubmed/35675945
http://dx.doi.org/10.1136/bmjoq-2021-001777
_version_ 1784724753281449984
author Malik, Fahad Siddique
Ghazal Asswad, Randa
Clarke, Simon
author_facet Malik, Fahad Siddique
Ghazal Asswad, Randa
Clarke, Simon
author_sort Malik, Fahad Siddique
collection PubMed
description BACKGROUND: Carbon monoxide (CO) is an odourless gas produced by the incomplete combustion of carbon containing materials. CO poisoning causes a range of symptoms of which headache is the most common, occurring in up to 90% of patients. An audit in the Emergency Department at University Hospital Aintree, Liverpool, UK found a lack of clinical awareness among healthcare professionals (HCPs) with CO exposure being considered in only 0.8% of patients presenting with non-traumatic headache. This Quality Improvement Project (QIP) aimed to increase this consideration to 50% of presentations. METHODS: Three separate sequential Plan Do Study Act (PDSA) cycles were instigated. Interventions involved verbal reminders to frontline HCPs (cycle 1), using strategically placed CO posters (cycle 2) and finally designing and introducing a CO sticker education scheme (cycle 3). These stickers, highlighting the approved CO COMA acronym, were placed in patient notes to serve as a physical reminder for HCPs when seeing patients. Rapid cycle sequencing was used with each cycle lasting 2 weeks. Patient notes were analysed for evidence that the HCP considered a diagnosis of CO. RESULTS: An average of 61 patients were included in each PDSA cycle. Given baseline findings, each cycle demonstrated positive results with CO awareness being considered in 1.7% and 10.0% of patients with non-traumatic headache following cycles 1 and 2, respectively. The final PDSA cycle demonstrated significant increase in consideration of CO to 42.1% of non-traumatic headache presentations. CONCLUSION: This QIP demonstrated that even small interventions can lead to significant change in awareness of CO exposure. Implementation of a CO sticker education scheme is a feasible way of increasing awareness among emergency care professionals and serves as a low-cost, easy to use, transferable and sustainable solution to address the lack of CO awareness in acute emergency settings. Importantly, this serves to promote improved patient safety.
format Online
Article
Text
id pubmed-9185569
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-91855692022-06-16 Carbon monoxide: raising awareness of the silent killer in the emergency department Malik, Fahad Siddique Ghazal Asswad, Randa Clarke, Simon BMJ Open Qual Quality Improvement Report BACKGROUND: Carbon monoxide (CO) is an odourless gas produced by the incomplete combustion of carbon containing materials. CO poisoning causes a range of symptoms of which headache is the most common, occurring in up to 90% of patients. An audit in the Emergency Department at University Hospital Aintree, Liverpool, UK found a lack of clinical awareness among healthcare professionals (HCPs) with CO exposure being considered in only 0.8% of patients presenting with non-traumatic headache. This Quality Improvement Project (QIP) aimed to increase this consideration to 50% of presentations. METHODS: Three separate sequential Plan Do Study Act (PDSA) cycles were instigated. Interventions involved verbal reminders to frontline HCPs (cycle 1), using strategically placed CO posters (cycle 2) and finally designing and introducing a CO sticker education scheme (cycle 3). These stickers, highlighting the approved CO COMA acronym, were placed in patient notes to serve as a physical reminder for HCPs when seeing patients. Rapid cycle sequencing was used with each cycle lasting 2 weeks. Patient notes were analysed for evidence that the HCP considered a diagnosis of CO. RESULTS: An average of 61 patients were included in each PDSA cycle. Given baseline findings, each cycle demonstrated positive results with CO awareness being considered in 1.7% and 10.0% of patients with non-traumatic headache following cycles 1 and 2, respectively. The final PDSA cycle demonstrated significant increase in consideration of CO to 42.1% of non-traumatic headache presentations. CONCLUSION: This QIP demonstrated that even small interventions can lead to significant change in awareness of CO exposure. Implementation of a CO sticker education scheme is a feasible way of increasing awareness among emergency care professionals and serves as a low-cost, easy to use, transferable and sustainable solution to address the lack of CO awareness in acute emergency settings. Importantly, this serves to promote improved patient safety. BMJ Publishing Group 2022-06-08 /pmc/articles/PMC9185569/ /pubmed/35675945 http://dx.doi.org/10.1136/bmjoq-2021-001777 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Quality Improvement Report
Malik, Fahad Siddique
Ghazal Asswad, Randa
Clarke, Simon
Carbon monoxide: raising awareness of the silent killer in the emergency department
title Carbon monoxide: raising awareness of the silent killer in the emergency department
title_full Carbon monoxide: raising awareness of the silent killer in the emergency department
title_fullStr Carbon monoxide: raising awareness of the silent killer in the emergency department
title_full_unstemmed Carbon monoxide: raising awareness of the silent killer in the emergency department
title_short Carbon monoxide: raising awareness of the silent killer in the emergency department
title_sort carbon monoxide: raising awareness of the silent killer in the emergency department
topic Quality Improvement Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9185569/
https://www.ncbi.nlm.nih.gov/pubmed/35675945
http://dx.doi.org/10.1136/bmjoq-2021-001777
work_keys_str_mv AT malikfahadsiddique carbonmonoxideraisingawarenessofthesilentkillerintheemergencydepartment
AT ghazalasswadranda carbonmonoxideraisingawarenessofthesilentkillerintheemergencydepartment
AT clarkesimon carbonmonoxideraisingawarenessofthesilentkillerintheemergencydepartment