Cargando…

The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis

INTRODUCTION: Incidence of breast cancer (BC) in 2020 is about 2.26 million new cases. It is the first common cancer accounting for 11.7% of all cancer worldwide. Disease complications and the mortality rate of breast cancer are highly dependent on the early diagnosis. Therefore, novel human breast-...

Descripción completa

Detalles Bibliográficos
Autores principales: Rezanejad Gatabi, Zahra, Mirhoseini, Mehri, Khajeali, Nasrin, Rezanezhad Gatabi, Iman, Dabbaghianamiri, Maedeh, Dorri, Sara
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9186524/
https://www.ncbi.nlm.nih.gov/pubmed/35711881
http://dx.doi.org/10.1155/2022/8565490
_version_ 1784724954609090560
author Rezanejad Gatabi, Zahra
Mirhoseini, Mehri
Khajeali, Nasrin
Rezanezhad Gatabi, Iman
Dabbaghianamiri, Maedeh
Dorri, Sara
author_facet Rezanejad Gatabi, Zahra
Mirhoseini, Mehri
Khajeali, Nasrin
Rezanezhad Gatabi, Iman
Dabbaghianamiri, Maedeh
Dorri, Sara
author_sort Rezanejad Gatabi, Zahra
collection PubMed
description INTRODUCTION: Incidence of breast cancer (BC) in 2020 is about 2.26 million new cases. It is the first common cancer accounting for 11.7% of all cancer worldwide. Disease complications and the mortality rate of breast cancer are highly dependent on the early diagnosis. Therefore, novel human breast-imaging techniques play an important role in minimizing the breast cancer morbidity and mortality rate. Electrical impedance tomography (EIT) is a noninvasive technique to image the breast using the electrical impedance behavior of the body tissues. OBJECTIVES: The aims of this manuscript are as follows: (1) a comprehensive investigation of the accuracy of EIT for breast cancer diagnosis through searching pieces of evidence in the valid databases and (2) meta-analyses of the results. METHODS: The systematic search was performed in the electronic databases including PubMed, Web of Science, EMBASE, Science Direct, ProQuest, Scopus, and Google Scholar without time and language limitation until January 2021. Search terms were “EIT” and “Breast Cancer” with their synonyms. Relevant studies were included based on PRISMA and study objectives. Quality of studies and risk of bias were performed by QUADAS-2 tools. Then, relevant data were extracted in Excel form. The hierarchical/bivariate meta-analysis was performed with “metandi” package for the ROC plot of sensitivity and specificity. Forest plot of the Accuracy index and double arcsine transformations was applied to stabilize the variance. The heterogeneity of the studies was evaluated by the forest plots, χ2 test (assuming a significance at the a-level of 10%), and the I(2) statistic for the Accuracy index. RESULTS: A total of 4027 articles were found. Finally, 12 of which met our criteria. Overall, these articles included studies of 5487 breast cancer patients. EIT had an overall pooled sensitivity and specificity of 75.88% (95% CI, 61.92% to 85.89%) and 82.04% (95% CI, 69.72% to 90.06%), respectively. The pooled diagnostic odds ratio was 14.37 (95% CI, 6.22% to 33.20%), and the pooled effect of accuracy was 0.79 with 95% CI (0.73, 0.83). CONCLUSIONS: This study showed that EIT can be used as a useful method alongside mammography. EIT sensitivity could not be compared with the sensitivity of MRI, but in terms of specificity, it can be considered as a new method that probably can get more attention. Furthermore, large-scale studies will be needed to support the evidence.
format Online
Article
Text
id pubmed-9186524
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-91865242022-06-15 The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis Rezanejad Gatabi, Zahra Mirhoseini, Mehri Khajeali, Nasrin Rezanezhad Gatabi, Iman Dabbaghianamiri, Maedeh Dorri, Sara Breast J Review Article INTRODUCTION: Incidence of breast cancer (BC) in 2020 is about 2.26 million new cases. It is the first common cancer accounting for 11.7% of all cancer worldwide. Disease complications and the mortality rate of breast cancer are highly dependent on the early diagnosis. Therefore, novel human breast-imaging techniques play an important role in minimizing the breast cancer morbidity and mortality rate. Electrical impedance tomography (EIT) is a noninvasive technique to image the breast using the electrical impedance behavior of the body tissues. OBJECTIVES: The aims of this manuscript are as follows: (1) a comprehensive investigation of the accuracy of EIT for breast cancer diagnosis through searching pieces of evidence in the valid databases and (2) meta-analyses of the results. METHODS: The systematic search was performed in the electronic databases including PubMed, Web of Science, EMBASE, Science Direct, ProQuest, Scopus, and Google Scholar without time and language limitation until January 2021. Search terms were “EIT” and “Breast Cancer” with their synonyms. Relevant studies were included based on PRISMA and study objectives. Quality of studies and risk of bias were performed by QUADAS-2 tools. Then, relevant data were extracted in Excel form. The hierarchical/bivariate meta-analysis was performed with “metandi” package for the ROC plot of sensitivity and specificity. Forest plot of the Accuracy index and double arcsine transformations was applied to stabilize the variance. The heterogeneity of the studies was evaluated by the forest plots, χ2 test (assuming a significance at the a-level of 10%), and the I(2) statistic for the Accuracy index. RESULTS: A total of 4027 articles were found. Finally, 12 of which met our criteria. Overall, these articles included studies of 5487 breast cancer patients. EIT had an overall pooled sensitivity and specificity of 75.88% (95% CI, 61.92% to 85.89%) and 82.04% (95% CI, 69.72% to 90.06%), respectively. The pooled diagnostic odds ratio was 14.37 (95% CI, 6.22% to 33.20%), and the pooled effect of accuracy was 0.79 with 95% CI (0.73, 0.83). CONCLUSIONS: This study showed that EIT can be used as a useful method alongside mammography. EIT sensitivity could not be compared with the sensitivity of MRI, but in terms of specificity, it can be considered as a new method that probably can get more attention. Furthermore, large-scale studies will be needed to support the evidence. Hindawi 2022-05-26 /pmc/articles/PMC9186524/ /pubmed/35711881 http://dx.doi.org/10.1155/2022/8565490 Text en Copyright © 2022 Zahra Rezanejad Gatabi et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Rezanejad Gatabi, Zahra
Mirhoseini, Mehri
Khajeali, Nasrin
Rezanezhad Gatabi, Iman
Dabbaghianamiri, Maedeh
Dorri, Sara
The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis
title The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis
title_full The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis
title_fullStr The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis
title_full_unstemmed The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis
title_short The Accuracy of Electrical Impedance Tomography for Breast Cancer Detection: A Systematic Review and Meta-Analysis
title_sort accuracy of electrical impedance tomography for breast cancer detection: a systematic review and meta-analysis
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9186524/
https://www.ncbi.nlm.nih.gov/pubmed/35711881
http://dx.doi.org/10.1155/2022/8565490
work_keys_str_mv AT rezanejadgatabizahra theaccuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT mirhoseinimehri theaccuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT khajealinasrin theaccuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT rezanezhadgatabiiman theaccuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT dabbaghianamirimaedeh theaccuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT dorrisara theaccuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT rezanejadgatabizahra accuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT mirhoseinimehri accuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT khajealinasrin accuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT rezanezhadgatabiiman accuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT dabbaghianamirimaedeh accuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis
AT dorrisara accuracyofelectricalimpedancetomographyforbreastcancerdetectionasystematicreviewandmetaanalysis