Cargando…
A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy
Background and study aims Indeterminate biliary strictures represent a major challenge in clinical diagnostics. Diagnostic yield of radiological, endoscopic imaging and histopathological diagnosis is insufficient. The cryobiopsy technique is a new method for tissue extraction already used in differ...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2022
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9187366/ https://www.ncbi.nlm.nih.gov/pubmed/35692925 http://dx.doi.org/10.1055/a-1797-8966 |
_version_ | 1784725151388008448 |
---|---|
author | Wirsing, Lukas Linzenbold, Walter Jaeger, Simon U. Stahl, Phillip Ott, German Leibold, Tobias Enderle, Markus Albert, Jörg Peveling-Oberhag, Jan |
author_facet | Wirsing, Lukas Linzenbold, Walter Jaeger, Simon U. Stahl, Phillip Ott, German Leibold, Tobias Enderle, Markus Albert, Jörg Peveling-Oberhag, Jan |
author_sort | Wirsing, Lukas |
collection | PubMed |
description | Background and study aims Indeterminate biliary strictures represent a major challenge in clinical diagnostics. Diagnostic yield of radiological, endoscopic imaging and histopathological diagnosis is insufficient. The cryobiopsy technique is a new method for tissue extraction already used in different clinical settings. The aim of this ex vivo clinical study was to investigate feasibility and tissue quality of cryobiopsy in the bile duct. Patients and methods We included 14 patients who underwent pancreaticoduodenectomy. Bile duct samples were taken with either a new prototype cryoprobe or one of two forceps types. Results were analyzed for general feasibility, specimen size, histological assessability as well as representativity of retrieved tissue. Results Feasibility of cholangioscopic forceps was poor compared to gastric biopsy forceps or cryobiopsy. Significantly larger tissue samples were obtained with cryobiopsy (5.6 ± 4.5 mm (2) ) compared to gastric biopsy forceps (3.3 ± 5.1 mm (2) , P = 0.006). Furthermore, cryobiopsy was superior in histological assessment quality ( P = 0.02) and concerning representativity ( P = 0.03). Conclusions Cryobiopsy in the bile duct is feasible and the quality of the obtained tissue is high. Further investigation of bile duct cryobiopsy in vivo is warranted. |
format | Online Article Text |
id | pubmed-9187366 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-91873662022-06-11 A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy Wirsing, Lukas Linzenbold, Walter Jaeger, Simon U. Stahl, Phillip Ott, German Leibold, Tobias Enderle, Markus Albert, Jörg Peveling-Oberhag, Jan Endosc Int Open Background and study aims Indeterminate biliary strictures represent a major challenge in clinical diagnostics. Diagnostic yield of radiological, endoscopic imaging and histopathological diagnosis is insufficient. The cryobiopsy technique is a new method for tissue extraction already used in different clinical settings. The aim of this ex vivo clinical study was to investigate feasibility and tissue quality of cryobiopsy in the bile duct. Patients and methods We included 14 patients who underwent pancreaticoduodenectomy. Bile duct samples were taken with either a new prototype cryoprobe or one of two forceps types. Results were analyzed for general feasibility, specimen size, histological assessability as well as representativity of retrieved tissue. Results Feasibility of cholangioscopic forceps was poor compared to gastric biopsy forceps or cryobiopsy. Significantly larger tissue samples were obtained with cryobiopsy (5.6 ± 4.5 mm (2) ) compared to gastric biopsy forceps (3.3 ± 5.1 mm (2) , P = 0.006). Furthermore, cryobiopsy was superior in histological assessment quality ( P = 0.02) and concerning representativity ( P = 0.03). Conclusions Cryobiopsy in the bile duct is feasible and the quality of the obtained tissue is high. Further investigation of bile duct cryobiopsy in vivo is warranted. Georg Thieme Verlag KG 2022-06-10 /pmc/articles/PMC9187366/ /pubmed/35692925 http://dx.doi.org/10.1055/a-1797-8966 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited. |
spellingShingle | Wirsing, Lukas Linzenbold, Walter Jaeger, Simon U. Stahl, Phillip Ott, German Leibold, Tobias Enderle, Markus Albert, Jörg Peveling-Oberhag, Jan A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy |
title | A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy |
title_full | A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy |
title_fullStr | A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy |
title_full_unstemmed | A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy |
title_short | A new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy |
title_sort | new tool for bile duct tissue sampling: ex vivo clinical evaluation of intraductal cryobiopsy for cholangioscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9187366/ https://www.ncbi.nlm.nih.gov/pubmed/35692925 http://dx.doi.org/10.1055/a-1797-8966 |
work_keys_str_mv | AT wirsinglukas anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT linzenboldwalter anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT jaegersimonu anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT stahlphillip anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT ottgerman anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT leiboldtobias anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT enderlemarkus anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT albertjorg anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT pevelingoberhagjan anewtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT wirsinglukas newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT linzenboldwalter newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT jaegersimonu newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT stahlphillip newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT ottgerman newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT leiboldtobias newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT enderlemarkus newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT albertjorg newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy AT pevelingoberhagjan newtoolforbileducttissuesamplingexvivoclinicalevaluationofintraductalcryobiopsyforcholangioscopy |