The “Shiny and Thick High Heel Sign”: A novel radiologic sign for detecting intracranial dural arteriovenous fistulas with time-of-flight magnetic resonance angiography

PURPOSE: Together with the foramen ovale, the middle meningeal artery (MMA) looks like a high heel shoe print on axial time-of-flight magnetic resonance angiography (TOF-MRA) images, with the MMA resembling the heel. Cranial dural arteriovenous fistulas (DAVF) are often fed by the MMA, which can lea...

Descripción completa

Detalles Bibliográficos
Autores principales: Schacht, Hannes, König, Inke Regina, Hensler, Johannes, Schramm, Peter, Küchler, Jan, Ditz, Claudia, Neumann, Alexander
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9187571/
https://www.ncbi.nlm.nih.gov/pubmed/34104975
http://dx.doi.org/10.1007/s00062-021-01036-y
Descripción
Sumario:PURPOSE: Together with the foramen ovale, the middle meningeal artery (MMA) looks like a high heel shoe print on axial time-of-flight magnetic resonance angiography (TOF-MRA) images, with the MMA resembling the heel. Cranial dural arteriovenous fistulas (DAVF) are often fed by the MMA, which can lead to an increase of signal intensity and diameter of this vessel, resulting in a more “shiny” and “thick” high heel print appearance than on the contralateral side. We describe this finding as a novel radiologic sign and provide cut-off values for the ratios of MMA signal intensities and diameters for predicting the presence of a DAVF. METHODS: A total of 84 TOF-MRA examinations of 44 patients with DAVFs (40 with unilateral MMA feeders, 4 with bilateral feeders) and of 40 patients without DAVFs were included. Diameters and signal intensities of both MMAs were measured by two raters and evaluated using receiver operating characteristic analysis. RESULTS: The diameters of feeding and non-feeding MMAs differed significantly, as did the ratios of signal intensities and of diameters of DAVF and control patients (P < 0.0001). Cut-off values were 1.25 for average signal intensity ratio (shiny high heel sign) and 1.21 for diameter ratio (thick high heel sign). The combination of the “shiny” and the “thick” high heel sign resulted in the highest sensitivity (92.5%) and positive predictive value (95%). CONCLUSION: The described sign seems promising for the detection of DAVFs with noncontrast-enhanced MRI. The TOF-MRA source images should be reviewed with special attention to the MMA.