Cargando…
Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application
Cherenkov emission (CE) is a visible blueish light emitted in water mediums irradiated by most radiotherapy treatment beams. However, CE is produced anisotropically which currently imposes a geometrical constraint uncertainty for dose measurements. In this work, polarization imaging is proposed and...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9187683/ https://www.ncbi.nlm.nih.gov/pubmed/35688843 http://dx.doi.org/10.1038/s41598-022-12672-w |
_version_ | 1784725218594390016 |
---|---|
author | Cloutier, Émily Beaulieu, Luc Archambault, Louis |
author_facet | Cloutier, Émily Beaulieu, Luc Archambault, Louis |
author_sort | Cloutier, Émily |
collection | PubMed |
description | Cherenkov emission (CE) is a visible blueish light emitted in water mediums irradiated by most radiotherapy treatment beams. However, CE is produced anisotropically which currently imposes a geometrical constraint uncertainty for dose measurements. In this work, polarization imaging is proposed and described as a method enabling precise 2D dose measurements using CE. CE produced in a water tank is imaged from four polarization angles using a camera coupled to a rotating polarizer. Using Malus’ law, the polarized component of CE is isolated and corrected with Monte Carlo calculated CE polar and azimuthal angular distributions. Projected dose measurements resulting from polarization-corrected CE are compared to equivalent radiochromic film measurements. Overall, agreement between polarized corrected CE signal and films measurements is found to be within 3%, for projected percent depth dose (PPDD) and profiles at the different tested energies ([Formula: see text] : 6 and [Formula: see text] , e[Formula: see text]: 6 and 18[Formula: see text] ). In comparison, raw Cherenkov emission presented deviations up 60% for electron beam PPDDs and 20% for photon beams PPDDs. Finally, a degree of linear polarization between 29% and 47% was measured for CE in comparison to [Formula: see text] % for scintillation. Hence, polarization imaging is found to be a promising and powerful method for improved radio-luminescent dose measurements with possible extensions to signal separation. |
format | Online Article Text |
id | pubmed-9187683 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-91876832022-06-12 Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application Cloutier, Émily Beaulieu, Luc Archambault, Louis Sci Rep Article Cherenkov emission (CE) is a visible blueish light emitted in water mediums irradiated by most radiotherapy treatment beams. However, CE is produced anisotropically which currently imposes a geometrical constraint uncertainty for dose measurements. In this work, polarization imaging is proposed and described as a method enabling precise 2D dose measurements using CE. CE produced in a water tank is imaged from four polarization angles using a camera coupled to a rotating polarizer. Using Malus’ law, the polarized component of CE is isolated and corrected with Monte Carlo calculated CE polar and azimuthal angular distributions. Projected dose measurements resulting from polarization-corrected CE are compared to equivalent radiochromic film measurements. Overall, agreement between polarized corrected CE signal and films measurements is found to be within 3%, for projected percent depth dose (PPDD) and profiles at the different tested energies ([Formula: see text] : 6 and [Formula: see text] , e[Formula: see text]: 6 and 18[Formula: see text] ). In comparison, raw Cherenkov emission presented deviations up 60% for electron beam PPDDs and 20% for photon beams PPDDs. Finally, a degree of linear polarization between 29% and 47% was measured for CE in comparison to [Formula: see text] % for scintillation. Hence, polarization imaging is found to be a promising and powerful method for improved radio-luminescent dose measurements with possible extensions to signal separation. Nature Publishing Group UK 2022-06-10 /pmc/articles/PMC9187683/ /pubmed/35688843 http://dx.doi.org/10.1038/s41598-022-12672-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Cloutier, Émily Beaulieu, Luc Archambault, Louis Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application |
title | Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application |
title_full | Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application |
title_fullStr | Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application |
title_full_unstemmed | Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application |
title_short | Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application |
title_sort | direct in-water radiation dose measurements using cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9187683/ https://www.ncbi.nlm.nih.gov/pubmed/35688843 http://dx.doi.org/10.1038/s41598-022-12672-w |
work_keys_str_mv | AT cloutieremily directinwaterradiationdosemeasurementsusingcherenkovemissioncorrectedsignalsfrompolarizationimagingforaclinicalradiotherapyapplication AT beaulieuluc directinwaterradiationdosemeasurementsusingcherenkovemissioncorrectedsignalsfrompolarizationimagingforaclinicalradiotherapyapplication AT archambaultlouis directinwaterradiationdosemeasurementsusingcherenkovemissioncorrectedsignalsfrompolarizationimagingforaclinicalradiotherapyapplication |