Cargando…
Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study
BACKGROUND: Consumer-based activity trackers are increasingly used in research, as they have the potential to promote increased physical activity and can be used for estimating physical activity among participants. However, the accuracy of newer consumer-based devices is mostly unknown, and validati...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9187966/ https://www.ncbi.nlm.nih.gov/pubmed/35622397 http://dx.doi.org/10.2196/27248 |
_version_ | 1784725271976345600 |
---|---|
author | Henriksen, André Svartdal, Frode Grimsgaard, Sameline Hartvigsen, Gunnar Hopstock, Laila Arnesdatter |
author_facet | Henriksen, André Svartdal, Frode Grimsgaard, Sameline Hartvigsen, Gunnar Hopstock, Laila Arnesdatter |
author_sort | Henriksen, André |
collection | PubMed |
description | BACKGROUND: Consumer-based activity trackers are increasingly used in research, as they have the potential to promote increased physical activity and can be used for estimating physical activity among participants. However, the accuracy of newer consumer-based devices is mostly unknown, and validation studies are needed. OBJECTIVE: The objective of this study was to compare the Polar Vantage watch (Polar Electro Oy) and Oura ring (generation 2; Ōura Health Oy) activity trackers to research-based instruments for measuring physical activity, total energy expenditure, resting heart rate, and sleep duration in free-living adults. METHODS: A total of 21 participants wore 2 consumer-based activity trackers (Polar watch and Oura ring), an ActiGraph accelerometer (ActiGraph LLC), and an Actiheart accelerometer and heart rate monitor (CamNtech Ltd) and completed a sleep diary for up to 7 days. We assessed Polar watch and Oura ring validity and comparability for measuring physical activity, total energy expenditure, resting heart rate (Oura), and sleep duration. We analyzed repeated measures correlations, Bland-Altman plots, and mean absolute percentage errors. RESULTS: The Polar watch and Oura ring values strongly correlated (P<.001) with the ActiGraph values for steps (Polar: r=0.75, 95% CI 0.54-0.92; Oura: r=0.77, 95% CI 0.62-0.87), moderate-to-vigorous physical activity (Polar: r=0.76, 95% CI 0.62-0.88; Oura: r=0.70, 95% CI 0.49-0.82), and total energy expenditure (Polar: r=0.69, 95% CI 0.48-0.88; Oura: r=0.70, 95% CI 0.51-0.83) and strongly or very strongly correlated (P<.001) with the sleep diary–derived sleep durations (Polar: r=0.74, 95% CI 0.56-0.88; Oura: r=0.82, 95% CI 0.68-0.91). Oura ring–derived resting heart rates had a very strong correlation (P<.001) with the Actiheart-derived resting heart rates (r=0.9, 95% CI 0.85-0.96). However, the mean absolute percentage error was high for all variables except Oura ring–derived sleep duration (10%) and resting heart rate (3%), which the Oura ring underreported on average by 1 beat per minute. CONCLUSIONS: The Oura ring can potentially be used as an alternative to the Actiheart to measure resting heart rate. As for sleep duration, the Polar watch and Oura ring can potentially be used as replacements for a manual sleep diary, depending on the acceptable error. Neither the Polar watch nor the Oura ring can replace the ActiGraph when it comes to measuring steps, moderate-to-vigorous physical activity, and total energy expenditure, but they may be used as additional sources of physical activity measures in some settings. On average, the Polar Vantage watch reported higher outputs compared to those reported by the Oura ring for steps, moderate-to-vigorous physical activity, and total energy expenditure. |
format | Online Article Text |
id | pubmed-9187966 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-91879662022-06-12 Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study Henriksen, André Svartdal, Frode Grimsgaard, Sameline Hartvigsen, Gunnar Hopstock, Laila Arnesdatter JMIR Form Res Original Paper BACKGROUND: Consumer-based activity trackers are increasingly used in research, as they have the potential to promote increased physical activity and can be used for estimating physical activity among participants. However, the accuracy of newer consumer-based devices is mostly unknown, and validation studies are needed. OBJECTIVE: The objective of this study was to compare the Polar Vantage watch (Polar Electro Oy) and Oura ring (generation 2; Ōura Health Oy) activity trackers to research-based instruments for measuring physical activity, total energy expenditure, resting heart rate, and sleep duration in free-living adults. METHODS: A total of 21 participants wore 2 consumer-based activity trackers (Polar watch and Oura ring), an ActiGraph accelerometer (ActiGraph LLC), and an Actiheart accelerometer and heart rate monitor (CamNtech Ltd) and completed a sleep diary for up to 7 days. We assessed Polar watch and Oura ring validity and comparability for measuring physical activity, total energy expenditure, resting heart rate (Oura), and sleep duration. We analyzed repeated measures correlations, Bland-Altman plots, and mean absolute percentage errors. RESULTS: The Polar watch and Oura ring values strongly correlated (P<.001) with the ActiGraph values for steps (Polar: r=0.75, 95% CI 0.54-0.92; Oura: r=0.77, 95% CI 0.62-0.87), moderate-to-vigorous physical activity (Polar: r=0.76, 95% CI 0.62-0.88; Oura: r=0.70, 95% CI 0.49-0.82), and total energy expenditure (Polar: r=0.69, 95% CI 0.48-0.88; Oura: r=0.70, 95% CI 0.51-0.83) and strongly or very strongly correlated (P<.001) with the sleep diary–derived sleep durations (Polar: r=0.74, 95% CI 0.56-0.88; Oura: r=0.82, 95% CI 0.68-0.91). Oura ring–derived resting heart rates had a very strong correlation (P<.001) with the Actiheart-derived resting heart rates (r=0.9, 95% CI 0.85-0.96). However, the mean absolute percentage error was high for all variables except Oura ring–derived sleep duration (10%) and resting heart rate (3%), which the Oura ring underreported on average by 1 beat per minute. CONCLUSIONS: The Oura ring can potentially be used as an alternative to the Actiheart to measure resting heart rate. As for sleep duration, the Polar watch and Oura ring can potentially be used as replacements for a manual sleep diary, depending on the acceptable error. Neither the Polar watch nor the Oura ring can replace the ActiGraph when it comes to measuring steps, moderate-to-vigorous physical activity, and total energy expenditure, but they may be used as additional sources of physical activity measures in some settings. On average, the Polar Vantage watch reported higher outputs compared to those reported by the Oura ring for steps, moderate-to-vigorous physical activity, and total energy expenditure. JMIR Publications 2022-05-27 /pmc/articles/PMC9187966/ /pubmed/35622397 http://dx.doi.org/10.2196/27248 Text en ©André Henriksen, Frode Svartdal, Sameline Grimsgaard, Gunnar Hartvigsen, Laila Arnesdatter Hopstock. Originally published in JMIR Formative Research (https://formative.jmir.org), 27.05.2022. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR Formative Research, is properly cited. The complete bibliographic information, a link to the original publication on https://formative.jmir.org, as well as this copyright and license information must be included. |
spellingShingle | Original Paper Henriksen, André Svartdal, Frode Grimsgaard, Sameline Hartvigsen, Gunnar Hopstock, Laila Arnesdatter Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study |
title | Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study |
title_full | Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study |
title_fullStr | Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study |
title_full_unstemmed | Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study |
title_short | Polar Vantage and Oura Physical Activity and Sleep Trackers: Validation and Comparison Study |
title_sort | polar vantage and oura physical activity and sleep trackers: validation and comparison study |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9187966/ https://www.ncbi.nlm.nih.gov/pubmed/35622397 http://dx.doi.org/10.2196/27248 |
work_keys_str_mv | AT henriksenandre polarvantageandouraphysicalactivityandsleeptrackersvalidationandcomparisonstudy AT svartdalfrode polarvantageandouraphysicalactivityandsleeptrackersvalidationandcomparisonstudy AT grimsgaardsameline polarvantageandouraphysicalactivityandsleeptrackersvalidationandcomparisonstudy AT hartvigsengunnar polarvantageandouraphysicalactivityandsleeptrackersvalidationandcomparisonstudy AT hopstocklailaarnesdatter polarvantageandouraphysicalactivityandsleeptrackersvalidationandcomparisonstudy |