Cargando…
Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
BACKGROUND: There are a variety of internal fixation methods for unstable femoral neck fractures (FNFs), but the best method is still unclear. Femoral neck system (FNS) is a dynamic angular stabilization system with cross screws, and is a new internal fixation implant designed for minimally invasive...
Autores principales: | Wang, Zheng, Yang, Yong, Feng, Gangning, Guo, Haohui, Chen, Zhirong, Chen, Yaogeng, Jin, Qunhua |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9188240/ https://www.ncbi.nlm.nih.gov/pubmed/35689282 http://dx.doi.org/10.1186/s12938-022-01006-6 |
Ejemplares similares
-
Intramedullary nails with cannulated screw fixation for the treatment
of unstable femoral neck fractures
por: Guo, Jialiang, et al.
Publicado: (2018) -
Biomechanical and clinical evaluation of interlocking hip screw in Pauwels Ⅲ femoral neck fractures: A comparison with inverted triangle cannulated screws
por: Zhang, Jian, et al.
Publicado: (2022) -
Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
por: Gao, Zhichao, et al.
Publicado: (2021) -
Treatment of Elderly Femoral Intertrochanteric Fracture by InterTan Intramedullary Nail and PFNA
por: Su, Zhengbing, et al.
Publicado: (2022) -
Comparison of Early Clinical Results for Femoral Neck System and Cannulated Screws in the Treatment of Unstable Femoral Neck Fractures
por: Zhou, Xiao‐qiang, et al.
Publicado: (2021)