Cargando…

An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations

A tuned liquid column damper (TLCD) is a passive vibration control device that not only mitigates unwanted structural vibrations but also acts as a water storage facility in a building. These aspects of TLCD make its application specifically suited for building structures. Previously, many experimen...

Descripción completa

Detalles Bibliográficos
Autores principales: Shah, Mati Ullah, Usman, Muhammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9191723/
https://www.ncbi.nlm.nih.gov/pubmed/35696409
http://dx.doi.org/10.1371/journal.pone.0269910
_version_ 1784726078892277760
author Shah, Mati Ullah
Usman, Muhammad
author_facet Shah, Mati Ullah
Usman, Muhammad
author_sort Shah, Mati Ullah
collection PubMed
description A tuned liquid column damper (TLCD) is a passive vibration control device that not only mitigates unwanted structural vibrations but also acts as a water storage facility in a building. These aspects of TLCD make its application specifically suited for building structures. Previously, many experimental works on TLCDs have been conducted considering a single degree of freedom (SDOF) structure. However, the performance of TLCDs to control the response of multi-degree of freedom (MDOF) structure has rarely been studied experimentally. Therefore, this study has investigated the performance of a tuned liquid column damper (TLCD) on a multi-degree of freedom (MDOF) structure using shake table testing. A four-storey steel frame structure equipped with TLCD at the top of the fourth storey has been studied. Experimental normalized frequency response curves for MDOF structure equipped with TLCD have been determined. For this purpose, a series of harmonic loadings including frequencies 0.65 Hz, 1.17 Hz, 1.30 Hz, 1.43 Hz and 1.95 Hz have been applied in addition to historic earthquake loading. Peak and root-mean-square (RMS) accelerations have been discussed in detail for all the applied loadings at each storey level of the structure. For comparison purposes, the percentage reductions in peak and RMS accelerations have been calculated and compared. Also, RMS displacements and inter-storey drifts have been presented for resonant and seismic excitations. Both in time and frequency domains, responses of controlled MDOF structure have been analyzed and compared with uncontrolled structure. Results confirmed that TLCD has improved the MDOF structure responses at harmonic loadings frequencies near resonance and historic earthquake excitations. Furthermore, the improvement in the responses of MDOF structure with TLCD is more prominent at harmonic loadings compared to historic earthquake loading.
format Online
Article
Text
id pubmed-9191723
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-91917232022-06-14 An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations Shah, Mati Ullah Usman, Muhammad PLoS One Research Article A tuned liquid column damper (TLCD) is a passive vibration control device that not only mitigates unwanted structural vibrations but also acts as a water storage facility in a building. These aspects of TLCD make its application specifically suited for building structures. Previously, many experimental works on TLCDs have been conducted considering a single degree of freedom (SDOF) structure. However, the performance of TLCDs to control the response of multi-degree of freedom (MDOF) structure has rarely been studied experimentally. Therefore, this study has investigated the performance of a tuned liquid column damper (TLCD) on a multi-degree of freedom (MDOF) structure using shake table testing. A four-storey steel frame structure equipped with TLCD at the top of the fourth storey has been studied. Experimental normalized frequency response curves for MDOF structure equipped with TLCD have been determined. For this purpose, a series of harmonic loadings including frequencies 0.65 Hz, 1.17 Hz, 1.30 Hz, 1.43 Hz and 1.95 Hz have been applied in addition to historic earthquake loading. Peak and root-mean-square (RMS) accelerations have been discussed in detail for all the applied loadings at each storey level of the structure. For comparison purposes, the percentage reductions in peak and RMS accelerations have been calculated and compared. Also, RMS displacements and inter-storey drifts have been presented for resonant and seismic excitations. Both in time and frequency domains, responses of controlled MDOF structure have been analyzed and compared with uncontrolled structure. Results confirmed that TLCD has improved the MDOF structure responses at harmonic loadings frequencies near resonance and historic earthquake excitations. Furthermore, the improvement in the responses of MDOF structure with TLCD is more prominent at harmonic loadings compared to historic earthquake loading. Public Library of Science 2022-06-13 /pmc/articles/PMC9191723/ /pubmed/35696409 http://dx.doi.org/10.1371/journal.pone.0269910 Text en © 2022 Shah, Usman https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Shah, Mati Ullah
Usman, Muhammad
An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations
title An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations
title_full An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations
title_fullStr An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations
title_full_unstemmed An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations
title_short An experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations
title_sort experimental study of tuned liquid column damper controlled multi-degree of freedom structure subject to harmonic and seismic excitations
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9191723/
https://www.ncbi.nlm.nih.gov/pubmed/35696409
http://dx.doi.org/10.1371/journal.pone.0269910
work_keys_str_mv AT shahmatiullah anexperimentalstudyoftunedliquidcolumndampercontrolledmultidegreeoffreedomstructuresubjecttoharmonicandseismicexcitations
AT usmanmuhammad anexperimentalstudyoftunedliquidcolumndampercontrolledmultidegreeoffreedomstructuresubjecttoharmonicandseismicexcitations
AT shahmatiullah experimentalstudyoftunedliquidcolumndampercontrolledmultidegreeoffreedomstructuresubjecttoharmonicandseismicexcitations
AT usmanmuhammad experimentalstudyoftunedliquidcolumndampercontrolledmultidegreeoffreedomstructuresubjecttoharmonicandseismicexcitations