Evaluation of a new laryngoscope blade (Manipal throat packing blade) for throat pack insertion
BACKGROUND AND AIMS: Insertion of a throat pack using a Macintosh laryngoscope after placing an oral Ring, Adair and Elwyn (RAE) tube fixed to the lower lip in the midline invariably results in the lateral movement of the tongue or the tube requiring repositioning. The aim was to design a laryngosco...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9191815/ https://www.ncbi.nlm.nih.gov/pubmed/35706633 http://dx.doi.org/10.4103/joacp.JOACP_24_20 |
_version_ | 1784726100780253184 |
---|---|
author | Muralikrishna, D Nileshwar, Anitha Budania, Lokvendra |
author_facet | Muralikrishna, D Nileshwar, Anitha Budania, Lokvendra |
author_sort | Muralikrishna, D |
collection | PubMed |
description | BACKGROUND AND AIMS: Insertion of a throat pack using a Macintosh laryngoscope after placing an oral Ring, Adair and Elwyn (RAE) tube fixed to the lower lip in the midline invariably results in the lateral movement of the tongue or the tube requiring repositioning. The aim was to design a laryngoscope blade that would produce minimal movement of the endotracheal tube or the tongue during the insertion of throat pack and compare it with the Macintosh laryngoscope blade. MATERIAL AND METHODS: A laryngoscope blade similar to the Doughty’s blade of Boyle Davis mouth gag with a groove in the center of the blade was initially designed. This was made of polyvinyl chloride to enable 3-D printing. Specifications given were modified after trial and error including addition of a flange. A bench study was then done to compare the Macintosh blade with the Manipal blade with and without flange. Forty anesthesia postgraduates and staff familiar with airway management inserted throat pack with each blade in random order in a manikin already intubated with an oral RAE tube and their impressions were noted. RESULTS: The RAE tube remained in the midline after throat packing in 97.5 and 95% with Manipal blade with and without flange as compared to 52.5% with Macintosh blade. Ease of use was affected by the lack of sturdiness of the new blades. The light was good. Most people found both blades better or the same as the Macintosh blade. CONCLUSION: The Manipal laryngoscope blade with and without flange are both associated with the minimal lateral movement of the endotracheal tube and are easy to use. Their sturdiness must be improved. |
format | Online Article Text |
id | pubmed-9191815 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-91918152022-06-14 Evaluation of a new laryngoscope blade (Manipal throat packing blade) for throat pack insertion Muralikrishna, D Nileshwar, Anitha Budania, Lokvendra J Anaesthesiol Clin Pharmacol Original Article BACKGROUND AND AIMS: Insertion of a throat pack using a Macintosh laryngoscope after placing an oral Ring, Adair and Elwyn (RAE) tube fixed to the lower lip in the midline invariably results in the lateral movement of the tongue or the tube requiring repositioning. The aim was to design a laryngoscope blade that would produce minimal movement of the endotracheal tube or the tongue during the insertion of throat pack and compare it with the Macintosh laryngoscope blade. MATERIAL AND METHODS: A laryngoscope blade similar to the Doughty’s blade of Boyle Davis mouth gag with a groove in the center of the blade was initially designed. This was made of polyvinyl chloride to enable 3-D printing. Specifications given were modified after trial and error including addition of a flange. A bench study was then done to compare the Macintosh blade with the Manipal blade with and without flange. Forty anesthesia postgraduates and staff familiar with airway management inserted throat pack with each blade in random order in a manikin already intubated with an oral RAE tube and their impressions were noted. RESULTS: The RAE tube remained in the midline after throat packing in 97.5 and 95% with Manipal blade with and without flange as compared to 52.5% with Macintosh blade. Ease of use was affected by the lack of sturdiness of the new blades. The light was good. Most people found both blades better or the same as the Macintosh blade. CONCLUSION: The Manipal laryngoscope blade with and without flange are both associated with the minimal lateral movement of the endotracheal tube and are easy to use. Their sturdiness must be improved. Wolters Kluwer - Medknow 2022 2022-01-28 /pmc/articles/PMC9191815/ /pubmed/35706633 http://dx.doi.org/10.4103/joacp.JOACP_24_20 Text en Copyright: © 2022 Journal of Anaesthesiology Clinical Pharmacology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Muralikrishna, D Nileshwar, Anitha Budania, Lokvendra Evaluation of a new laryngoscope blade (Manipal throat packing blade) for throat pack insertion |
title | Evaluation of a new laryngoscope blade (Manipal throat packing blade) for throat pack insertion |
title_full | Evaluation of a new laryngoscope blade (Manipal throat packing blade) for throat pack insertion |
title_fullStr | Evaluation of a new laryngoscope blade (Manipal throat packing blade) for throat pack insertion |
title_full_unstemmed | Evaluation of a new laryngoscope blade (Manipal throat packing blade) for throat pack insertion |
title_short | Evaluation of a new laryngoscope blade (Manipal throat packing blade) for throat pack insertion |
title_sort | evaluation of a new laryngoscope blade (manipal throat packing blade) for throat pack insertion |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9191815/ https://www.ncbi.nlm.nih.gov/pubmed/35706633 http://dx.doi.org/10.4103/joacp.JOACP_24_20 |
work_keys_str_mv | AT muralikrishnad evaluationofanewlaryngoscopeblademanipalthroatpackingbladeforthroatpackinsertion AT nileshwaranitha evaluationofanewlaryngoscopeblademanipalthroatpackingbladeforthroatpackinsertion AT budanialokvendra evaluationofanewlaryngoscopeblademanipalthroatpackingbladeforthroatpackinsertion |