Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography

PURPOSE: To compare anterior biometry measurements using placido-scanning-slit topography, rotating Scheimpflug tomography, and swept-source optical coherence tomography. METHODS: A retrospective review consisted of 80 eyes of 49 participants who underwent anterior chamber depth (ACD), central corne...

Descripción completa

Detalles Bibliográficos
Autores principales: Ryu, Soyoung, Yoon, Sook Hyun, Jun, Ikhyun, Seo, Kyoung Yul, Kim, Eung Kweon, Kim, Tae-im
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Ophthalmological Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9194728/
https://www.ncbi.nlm.nih.gov/pubmed/35527529
http://dx.doi.org/10.3341/kjo.2021.0120
_version_ 1784726785631453184
author Ryu, Soyoung
Yoon, Sook Hyun
Jun, Ikhyun
Seo, Kyoung Yul
Kim, Eung Kweon
Kim, Tae-im
author_facet Ryu, Soyoung
Yoon, Sook Hyun
Jun, Ikhyun
Seo, Kyoung Yul
Kim, Eung Kweon
Kim, Tae-im
author_sort Ryu, Soyoung
collection PubMed
description PURPOSE: To compare anterior biometry measurements using placido-scanning-slit topography, rotating Scheimpflug tomography, and swept-source optical coherence tomography. METHODS: A retrospective review consisted of 80 eyes of 49 participants who underwent anterior chamber depth (ACD), central corneal thickness (CCT), and keratometry examination on the same day. We used placido-scanning-slit topography (ORBscan II), rotating Scheimpflug tomography (Pentacam HR), and swept-source optical coherence tomography (CASIA SS-1000). The intraclass correlation coefficients and Bland-Altman plots were used to evaluate the agreement and differences between measurements. RESULTS: The mean ACD values were 2.88 ± 0.43, 2.82 ± 0.50, and 2.68 ± 0.44 mm; and the mean CCT values were 536.96 ± 31.19, 543.79 ± 31.04, and 561.41 ± 32.60 μm; and the mean keratometry (Km) were 43.81 ± 1.69, 43.81 ± 1.77, and 44.65 ± 1.95 diopters; as measured by CASIA SS-1000, Pentacam HR, and ORBscan II, respectively. Among the three devices, ACD was deepest to shallowest in the order of CASIA SS-1000, Pentacam HR, and ORBscan II (p < 0.05). The CCT was thickest to thinnest in the order of ORBscan II, Pentacam HR, and CASIA SS-1000 (p < 0.05). No significant differences in Km values were examined between CASIA SS-1000 and Pentacam HR, whereas ORBscan II overestimated Km with a statistically significant difference compared to the other two devices. CONCLUSIONS: High level of agreement was found between CASIA SS-1000 and Pentacam HR for anterior parameters, including ACD, CCT, and Km, suggesting interchangeability. However, ORBscan II measurements differed considerably with the measurements obtained from the other two devices; therefore, it should not be used interchangeably. However, further studies with repeatability test should be considered in order to elucidate the reliability of each device.
format Online
Article
Text
id pubmed-9194728
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-91947282022-06-16 Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography Ryu, Soyoung Yoon, Sook Hyun Jun, Ikhyun Seo, Kyoung Yul Kim, Eung Kweon Kim, Tae-im Korean J Ophthalmol Original Article PURPOSE: To compare anterior biometry measurements using placido-scanning-slit topography, rotating Scheimpflug tomography, and swept-source optical coherence tomography. METHODS: A retrospective review consisted of 80 eyes of 49 participants who underwent anterior chamber depth (ACD), central corneal thickness (CCT), and keratometry examination on the same day. We used placido-scanning-slit topography (ORBscan II), rotating Scheimpflug tomography (Pentacam HR), and swept-source optical coherence tomography (CASIA SS-1000). The intraclass correlation coefficients and Bland-Altman plots were used to evaluate the agreement and differences between measurements. RESULTS: The mean ACD values were 2.88 ± 0.43, 2.82 ± 0.50, and 2.68 ± 0.44 mm; and the mean CCT values were 536.96 ± 31.19, 543.79 ± 31.04, and 561.41 ± 32.60 μm; and the mean keratometry (Km) were 43.81 ± 1.69, 43.81 ± 1.77, and 44.65 ± 1.95 diopters; as measured by CASIA SS-1000, Pentacam HR, and ORBscan II, respectively. Among the three devices, ACD was deepest to shallowest in the order of CASIA SS-1000, Pentacam HR, and ORBscan II (p < 0.05). The CCT was thickest to thinnest in the order of ORBscan II, Pentacam HR, and CASIA SS-1000 (p < 0.05). No significant differences in Km values were examined between CASIA SS-1000 and Pentacam HR, whereas ORBscan II overestimated Km with a statistically significant difference compared to the other two devices. CONCLUSIONS: High level of agreement was found between CASIA SS-1000 and Pentacam HR for anterior parameters, including ACD, CCT, and Km, suggesting interchangeability. However, ORBscan II measurements differed considerably with the measurements obtained from the other two devices; therefore, it should not be used interchangeably. However, further studies with repeatability test should be considered in order to elucidate the reliability of each device. Korean Ophthalmological Society 2022-06 2022-05-06 /pmc/articles/PMC9194728/ /pubmed/35527529 http://dx.doi.org/10.3341/kjo.2021.0120 Text en © 2022 The Korean Ophthalmological Society https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access journal distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ryu, Soyoung
Yoon, Sook Hyun
Jun, Ikhyun
Seo, Kyoung Yul
Kim, Eung Kweon
Kim, Tae-im
Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography
title Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography
title_full Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography
title_fullStr Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography
title_full_unstemmed Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography
title_short Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography
title_sort anterior ocular biometrics using placido-scanning-slit system, rotating scheimpflug tomography, and swept-source optical coherence tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9194728/
https://www.ncbi.nlm.nih.gov/pubmed/35527529
http://dx.doi.org/10.3341/kjo.2021.0120
work_keys_str_mv AT ryusoyoung anteriorocularbiometricsusingplacidoscanningslitsystemrotatingscheimpflugtomographyandsweptsourceopticalcoherencetomography
AT yoonsookhyun anteriorocularbiometricsusingplacidoscanningslitsystemrotatingscheimpflugtomographyandsweptsourceopticalcoherencetomography
AT junikhyun anteriorocularbiometricsusingplacidoscanningslitsystemrotatingscheimpflugtomographyandsweptsourceopticalcoherencetomography
AT seokyoungyul anteriorocularbiometricsusingplacidoscanningslitsystemrotatingscheimpflugtomographyandsweptsourceopticalcoherencetomography
AT kimeungkweon anteriorocularbiometricsusingplacidoscanningslitsystemrotatingscheimpflugtomographyandsweptsourceopticalcoherencetomography
AT kimtaeim anteriorocularbiometricsusingplacidoscanningslitsystemrotatingscheimpflugtomographyandsweptsourceopticalcoherencetomography