Cargando…

Integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories

INTRODUCTION: The modern approach to quality control (QC) in medical laboratories implies the development of a risk-based control plan. This paper aims to develop a risk-based QC plan for a laboratory with a small daily testing volume and to integrate the already optimized moving average (MA) contro...

Descripción completa

Detalles Bibliográficos
Autores principales: Lukić, Vera, Ignjatović, Svetlana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Croatian Society of Medical Biochemistry and Laboratory Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9195605/
https://www.ncbi.nlm.nih.gov/pubmed/35799981
http://dx.doi.org/10.11613/BM.2022.020711
_version_ 1784727002227408896
author Lukić, Vera
Ignjatović, Svetlana
author_facet Lukić, Vera
Ignjatović, Svetlana
author_sort Lukić, Vera
collection PubMed
description INTRODUCTION: The modern approach to quality control (QC) in medical laboratories implies the development of a risk-based control plan. This paper aims to develop a risk-based QC plan for a laboratory with a small daily testing volume and to integrate the already optimized moving average (MA) control procedures into this plan. MATERIALS AND METHODS: A multistage bracketed QC plan for ten clinical chemistry analytes was made using a Westgard QC frequency calculator. Previously, MA procedures were optimized by the bias detection simulation method. RESULTS: Aspartate aminotransferase, HDL-cholesterol and potassium had patient-risk sigma metrics greater than 6, albumin and cholesterol greater than 5, creatinine, chlorides, calcium and total proteins between 4 and 5, and sodium less than 4. Based on the calculated run sizes and characteristics of optimized MA procedures, for 6 tests, it was possible to replace the monitoring QC procedure with an MA procedure. For the remaining 4 tests, it was necessary to keep the monitoring QC procedure and introduce MA control for added security. CONCLUSION: This study showed that even in a laboratory with a small volume of daily testing, it is possible to make a risk-based QC plan and integrate MA control procedures into that plan.
format Online
Article
Text
id pubmed-9195605
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Croatian Society of Medical Biochemistry and Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-91956052022-07-06 Integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories Lukić, Vera Ignjatović, Svetlana Biochem Med (Zagreb) Original Articles INTRODUCTION: The modern approach to quality control (QC) in medical laboratories implies the development of a risk-based control plan. This paper aims to develop a risk-based QC plan for a laboratory with a small daily testing volume and to integrate the already optimized moving average (MA) control procedures into this plan. MATERIALS AND METHODS: A multistage bracketed QC plan for ten clinical chemistry analytes was made using a Westgard QC frequency calculator. Previously, MA procedures were optimized by the bias detection simulation method. RESULTS: Aspartate aminotransferase, HDL-cholesterol and potassium had patient-risk sigma metrics greater than 6, albumin and cholesterol greater than 5, creatinine, chlorides, calcium and total proteins between 4 and 5, and sodium less than 4. Based on the calculated run sizes and characteristics of optimized MA procedures, for 6 tests, it was possible to replace the monitoring QC procedure with an MA procedure. For the remaining 4 tests, it was necessary to keep the monitoring QC procedure and introduce MA control for added security. CONCLUSION: This study showed that even in a laboratory with a small volume of daily testing, it is possible to make a risk-based QC plan and integrate MA control procedures into that plan. Croatian Society of Medical Biochemistry and Laboratory Medicine 2022-06-15 2022-06-15 /pmc/articles/PMC9195605/ /pubmed/35799981 http://dx.doi.org/10.11613/BM.2022.020711 Text en Croatian Society of Medical Biochemistry and Laboratory Medicine. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Lukić, Vera
Ignjatović, Svetlana
Integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories
title Integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories
title_full Integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories
title_fullStr Integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories
title_full_unstemmed Integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories
title_short Integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories
title_sort integrating moving average control procedures into the risk-based quality control plan in small-volume medical laboratories
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9195605/
https://www.ncbi.nlm.nih.gov/pubmed/35799981
http://dx.doi.org/10.11613/BM.2022.020711
work_keys_str_mv AT lukicvera integratingmovingaveragecontrolproceduresintotheriskbasedqualitycontrolplaninsmallvolumemedicallaboratories
AT ignjatovicsvetlana integratingmovingaveragecontrolproceduresintotheriskbasedqualitycontrolplaninsmallvolumemedicallaboratories