Cargando…
Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report
BACKGROUND: Surgical repair of complex abdominal aortic aneurysm is associated with a higher perioperative mortality and morbidity. The advent of endovascular aortic repair (EVAR) has reduced perioperative complications, although the utilization of such techniques is limited by lesion characteristic...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9198850/ https://www.ncbi.nlm.nih.gov/pubmed/35801037 http://dx.doi.org/10.12998/wjcc.v10.i15.5005 |
_version_ | 1784727732117045248 |
---|---|
author | Jang, Albert Youngwoo Oh, Pyung Chun Kang, Jin Mo Park, Chul Hyun Kang, Woong Chol |
author_facet | Jang, Albert Youngwoo Oh, Pyung Chun Kang, Jin Mo Park, Chul Hyun Kang, Woong Chol |
author_sort | Jang, Albert Youngwoo |
collection | PubMed |
description | BACKGROUND: Surgical repair of complex abdominal aortic aneurysm is associated with a higher perioperative mortality and morbidity. The advent of endovascular aortic repair (EVAR) has reduced perioperative complications, although the utilization of such techniques is limited by lesion characteristics, such as involvement of the visceral or renal arteries (RA) and/or presence of a sealing zone. CASE SUMMARY: A 60-year-old male presented with a Crawford type IV complex thoracoabdominal aortic aneurysm (CAAA) starting directly distal to the diaphragm extending to both common iliac arteries (CIAs). The CAAA consist of a proximal and distal aneurysmal sac separated by a 1 cm-healthy zone in the infrarenal level. Due to the poor performance of the patient and the expansive disease, we planned a stepwise-combined surgery and EVAR to minimize invasiveness. A branched graft was implanted after surgical debranching of the visceral and RA. Since the patient had renal and liver injury after surgery, the second stage EVAR was performed 10 mo later. The stent graft was implanted from the distal portion of surgical branched graft to both CIAs during EVAR. The patient has been uneventful for 5-years after discharge and is being followed in the outpatient clinic. CONCLUSION: The current case demonstrates that the surgical graft can provide a landing zone for second stage EVAR to avoid aggressive surgery in patients with poor performance with a long hostile CAAA. |
format | Online Article Text |
id | pubmed-9198850 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-91988502022-07-06 Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report Jang, Albert Youngwoo Oh, Pyung Chun Kang, Jin Mo Park, Chul Hyun Kang, Woong Chol World J Clin Cases Case Report BACKGROUND: Surgical repair of complex abdominal aortic aneurysm is associated with a higher perioperative mortality and morbidity. The advent of endovascular aortic repair (EVAR) has reduced perioperative complications, although the utilization of such techniques is limited by lesion characteristics, such as involvement of the visceral or renal arteries (RA) and/or presence of a sealing zone. CASE SUMMARY: A 60-year-old male presented with a Crawford type IV complex thoracoabdominal aortic aneurysm (CAAA) starting directly distal to the diaphragm extending to both common iliac arteries (CIAs). The CAAA consist of a proximal and distal aneurysmal sac separated by a 1 cm-healthy zone in the infrarenal level. Due to the poor performance of the patient and the expansive disease, we planned a stepwise-combined surgery and EVAR to minimize invasiveness. A branched graft was implanted after surgical debranching of the visceral and RA. Since the patient had renal and liver injury after surgery, the second stage EVAR was performed 10 mo later. The stent graft was implanted from the distal portion of surgical branched graft to both CIAs during EVAR. The patient has been uneventful for 5-years after discharge and is being followed in the outpatient clinic. CONCLUSION: The current case demonstrates that the surgical graft can provide a landing zone for second stage EVAR to avoid aggressive surgery in patients with poor performance with a long hostile CAAA. Baishideng Publishing Group Inc 2022-05-26 2022-05-26 /pmc/articles/PMC9198850/ /pubmed/35801037 http://dx.doi.org/10.12998/wjcc.v10.i15.5005 Text en ©The Author(s) 2022. Published by Baishideng Publishing Group Inc. All rights reserved. https://creativecommons.org/licenses/by-nc/4.0/This article is an open-access article that was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution NonCommercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: https://creativecommons.org/Licenses/by-nc/4.0/ |
spellingShingle | Case Report Jang, Albert Youngwoo Oh, Pyung Chun Kang, Jin Mo Park, Chul Hyun Kang, Woong Chol Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report |
title | Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report |
title_full | Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report |
title_fullStr | Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report |
title_full_unstemmed | Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report |
title_short | Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report |
title_sort | extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9198850/ https://www.ncbi.nlm.nih.gov/pubmed/35801037 http://dx.doi.org/10.12998/wjcc.v10.i15.5005 |
work_keys_str_mv | AT jangalbertyoungwoo extensivecomplexthoracoabdominalaorticaneurysmsalvagedbysurgicalgraftprovidinglandingzoneforendovasculargraftacasereport AT ohpyungchun extensivecomplexthoracoabdominalaorticaneurysmsalvagedbysurgicalgraftprovidinglandingzoneforendovasculargraftacasereport AT kangjinmo extensivecomplexthoracoabdominalaorticaneurysmsalvagedbysurgicalgraftprovidinglandingzoneforendovasculargraftacasereport AT parkchulhyun extensivecomplexthoracoabdominalaorticaneurysmsalvagedbysurgicalgraftprovidinglandingzoneforendovasculargraftacasereport AT kangwoongchol extensivecomplexthoracoabdominalaorticaneurysmsalvagedbysurgicalgraftprovidinglandingzoneforendovasculargraftacasereport |