Cargando…

Augmented Reality Device for Preoperative Marking of Spine Surgery Can Improve the Accuracy of Level Identification

INTRODUCTION: Wrong-site spine surgery is an incident that could result in possible severe complications. In this present spinal surgery, the accurate spinal level is confirmed via preoperative or intraoperative radiographic marking. However, the location of radiographic marking has been determined...

Descripción completa

Detalles Bibliográficos
Autores principales: Aoyama, Ryoma, Anazawa, Ukei, Hotta, Hiraku, Watanabe, Itsuo, Takahashi, Yuichiro, Matsumoto, Shogo, Ishibashi, Toshiki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Japanese Society for Spine Surgery and Related Research 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9200419/
https://www.ncbi.nlm.nih.gov/pubmed/35800633
http://dx.doi.org/10.22603/ssrr.2021-0168
_version_ 1784728056559042560
author Aoyama, Ryoma
Anazawa, Ukei
Hotta, Hiraku
Watanabe, Itsuo
Takahashi, Yuichiro
Matsumoto, Shogo
Ishibashi, Toshiki
author_facet Aoyama, Ryoma
Anazawa, Ukei
Hotta, Hiraku
Watanabe, Itsuo
Takahashi, Yuichiro
Matsumoto, Shogo
Ishibashi, Toshiki
author_sort Aoyama, Ryoma
collection PubMed
description INTRODUCTION: Wrong-site spine surgery is an incident that could result in possible severe complications. In this present spinal surgery, the accurate spinal level is confirmed via preoperative or intraoperative radiographic marking. However, the location of radiographic marking has been determined from the manual palpation on the landmarks of the body surface. As a result, severe spine deformity can make it hard to identify the spinal level by manual palpation, thus leading to misidentification of the spinal level. Recently, the use of mixed reality in spine surgery is gradually increasing. In this study, we will demonstrate a head-mounted display (HMD) device that can project a hologram (3D image) of the patient's bone onto the actual patient's body to improve the accuracy of level identification for spine surgery. TECHNICAL NOTE: 3D CT images are created preoperatively, and the bone's STL data (3D data) are generated with the workstation. The created STL data are downloaded to the augmented reality software Holoeyes, installed on the HMD. Through this device, surgeons can view the hologram (3D image) of a patient's bone overlaying on an actual patient's body. We temporally estimated the spinous process level only by manual palpation without an HMD. Then, we estimated the spinous process level again after matching this hologram to a real bone with an HMD. The accuracy of the level identification with an HMD and without an HMD was examined by radiographic marking in order to evaluate the misidentification rate of the level. Without an HMD, the misidentification rate of the level was at 26.5%, while with it, the rate was reduced to 14.3%. CONCLUSIONS: On preoperative marking, an HMD-projecting bone image onto a patient's body could allow us to estimate the spinal level more accurately. Identification of the spinal level using mixed reality is effective in preventing wrong-site spine surgery.
format Online
Article
Text
id pubmed-9200419
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Japanese Society for Spine Surgery and Related Research
record_format MEDLINE/PubMed
spelling pubmed-92004192022-07-06 Augmented Reality Device for Preoperative Marking of Spine Surgery Can Improve the Accuracy of Level Identification Aoyama, Ryoma Anazawa, Ukei Hotta, Hiraku Watanabe, Itsuo Takahashi, Yuichiro Matsumoto, Shogo Ishibashi, Toshiki Spine Surg Relat Res Technical Note INTRODUCTION: Wrong-site spine surgery is an incident that could result in possible severe complications. In this present spinal surgery, the accurate spinal level is confirmed via preoperative or intraoperative radiographic marking. However, the location of radiographic marking has been determined from the manual palpation on the landmarks of the body surface. As a result, severe spine deformity can make it hard to identify the spinal level by manual palpation, thus leading to misidentification of the spinal level. Recently, the use of mixed reality in spine surgery is gradually increasing. In this study, we will demonstrate a head-mounted display (HMD) device that can project a hologram (3D image) of the patient's bone onto the actual patient's body to improve the accuracy of level identification for spine surgery. TECHNICAL NOTE: 3D CT images are created preoperatively, and the bone's STL data (3D data) are generated with the workstation. The created STL data are downloaded to the augmented reality software Holoeyes, installed on the HMD. Through this device, surgeons can view the hologram (3D image) of a patient's bone overlaying on an actual patient's body. We temporally estimated the spinous process level only by manual palpation without an HMD. Then, we estimated the spinous process level again after matching this hologram to a real bone with an HMD. The accuracy of the level identification with an HMD and without an HMD was examined by radiographic marking in order to evaluate the misidentification rate of the level. Without an HMD, the misidentification rate of the level was at 26.5%, while with it, the rate was reduced to 14.3%. CONCLUSIONS: On preoperative marking, an HMD-projecting bone image onto a patient's body could allow us to estimate the spinal level more accurately. Identification of the spinal level using mixed reality is effective in preventing wrong-site spine surgery. The Japanese Society for Spine Surgery and Related Research 2021-11-04 /pmc/articles/PMC9200419/ /pubmed/35800633 http://dx.doi.org/10.22603/ssrr.2021-0168 Text en Copyright © 2022 by The Japanese Society for Spine Surgery and Related Research https://creativecommons.org/licenses/by-nc-nd/4.0/Spine Surgery and Related Research is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Technical Note
Aoyama, Ryoma
Anazawa, Ukei
Hotta, Hiraku
Watanabe, Itsuo
Takahashi, Yuichiro
Matsumoto, Shogo
Ishibashi, Toshiki
Augmented Reality Device for Preoperative Marking of Spine Surgery Can Improve the Accuracy of Level Identification
title Augmented Reality Device for Preoperative Marking of Spine Surgery Can Improve the Accuracy of Level Identification
title_full Augmented Reality Device for Preoperative Marking of Spine Surgery Can Improve the Accuracy of Level Identification
title_fullStr Augmented Reality Device for Preoperative Marking of Spine Surgery Can Improve the Accuracy of Level Identification
title_full_unstemmed Augmented Reality Device for Preoperative Marking of Spine Surgery Can Improve the Accuracy of Level Identification
title_short Augmented Reality Device for Preoperative Marking of Spine Surgery Can Improve the Accuracy of Level Identification
title_sort augmented reality device for preoperative marking of spine surgery can improve the accuracy of level identification
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9200419/
https://www.ncbi.nlm.nih.gov/pubmed/35800633
http://dx.doi.org/10.22603/ssrr.2021-0168
work_keys_str_mv AT aoyamaryoma augmentedrealitydeviceforpreoperativemarkingofspinesurgerycanimprovetheaccuracyoflevelidentification
AT anazawaukei augmentedrealitydeviceforpreoperativemarkingofspinesurgerycanimprovetheaccuracyoflevelidentification
AT hottahiraku augmentedrealitydeviceforpreoperativemarkingofspinesurgerycanimprovetheaccuracyoflevelidentification
AT watanabeitsuo augmentedrealitydeviceforpreoperativemarkingofspinesurgerycanimprovetheaccuracyoflevelidentification
AT takahashiyuichiro augmentedrealitydeviceforpreoperativemarkingofspinesurgerycanimprovetheaccuracyoflevelidentification
AT matsumotoshogo augmentedrealitydeviceforpreoperativemarkingofspinesurgerycanimprovetheaccuracyoflevelidentification
AT ishibashitoshiki augmentedrealitydeviceforpreoperativemarkingofspinesurgerycanimprovetheaccuracyoflevelidentification