Cargando…

Flame Propagation Characteristics of Syngas-Air in the Hele-Shaw Duct with Different Equivalence Ratios and Ignition Positions

[Image: see text] In this paper, the effects of different ignition positions and equivalence ratios on the explosion characteristics of syngas in a half-open Hele-Shaw duct were investigated. The ignition points are set at distances of 0 and 500 mm from the closed end. Moreover, the research range o...

Descripción completa

Detalles Bibliográficos
Autores principales: Diao, Shoutong, Wen, Xiaoping, Guo, Zhidong, He, Wenqiang, Deng, Haoxin, Wang, Fahui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2022
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9202038/
https://www.ncbi.nlm.nih.gov/pubmed/35721959
http://dx.doi.org/10.1021/acsomega.2c01960
_version_ 1784728446170038272
author Diao, Shoutong
Wen, Xiaoping
Guo, Zhidong
He, Wenqiang
Deng, Haoxin
Wang, Fahui
author_facet Diao, Shoutong
Wen, Xiaoping
Guo, Zhidong
He, Wenqiang
Deng, Haoxin
Wang, Fahui
author_sort Diao, Shoutong
collection PubMed
description [Image: see text] In this paper, the effects of different ignition positions and equivalence ratios on the explosion characteristics of syngas in a half-open Hele-Shaw duct were investigated. The ignition points are set at distances of 0 and 500 mm from the closed end. Moreover, the research range of equivalence ratio is 0.8–1.2. The experimental results indicate that different ignition positions and equivalence ratios influence the flame front structure and the dynamic characteristics of flame propagation. When the ignition position is at the closed end, the flame front undergoes several typical propagation stages before eventually reaching the open end of the duct. The time required by the flame to reach the open end decreases as the equivalence ratio increases. Meanwhile, when the ignition is in the middle of the duct, the flame simultaneously spreads to the open and closed ends. The time required to reach both sides decreases with the increase in the equivalence ratio. The flame front structure and pressure are primarily affected by the ignition position and the equivalence ratio. At the same ignition position, flame propagation velocity and maximum overpressure increase with the equivalence ratio. The pressure oscillation becomes more intense when the ignition position is close to the open end. At IP(500), when the equivalence ratio is 0.8, multiple finger-shaped flame fronts emerge, accompanied by high-frequency flame oscillations. This study can provide guidance for the study of the flame propagation characteristics of syngas in millimeter-scale burners.
format Online
Article
Text
id pubmed-9202038
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-92020382022-06-17 Flame Propagation Characteristics of Syngas-Air in the Hele-Shaw Duct with Different Equivalence Ratios and Ignition Positions Diao, Shoutong Wen, Xiaoping Guo, Zhidong He, Wenqiang Deng, Haoxin Wang, Fahui ACS Omega [Image: see text] In this paper, the effects of different ignition positions and equivalence ratios on the explosion characteristics of syngas in a half-open Hele-Shaw duct were investigated. The ignition points are set at distances of 0 and 500 mm from the closed end. Moreover, the research range of equivalence ratio is 0.8–1.2. The experimental results indicate that different ignition positions and equivalence ratios influence the flame front structure and the dynamic characteristics of flame propagation. When the ignition position is at the closed end, the flame front undergoes several typical propagation stages before eventually reaching the open end of the duct. The time required by the flame to reach the open end decreases as the equivalence ratio increases. Meanwhile, when the ignition is in the middle of the duct, the flame simultaneously spreads to the open and closed ends. The time required to reach both sides decreases with the increase in the equivalence ratio. The flame front structure and pressure are primarily affected by the ignition position and the equivalence ratio. At the same ignition position, flame propagation velocity and maximum overpressure increase with the equivalence ratio. The pressure oscillation becomes more intense when the ignition position is close to the open end. At IP(500), when the equivalence ratio is 0.8, multiple finger-shaped flame fronts emerge, accompanied by high-frequency flame oscillations. This study can provide guidance for the study of the flame propagation characteristics of syngas in millimeter-scale burners. American Chemical Society 2022-06-03 /pmc/articles/PMC9202038/ /pubmed/35721959 http://dx.doi.org/10.1021/acsomega.2c01960 Text en © 2022 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by-nc-nd/4.0/Permits non-commercial access and re-use, provided that author attribution and integrity are maintained; but does not permit creation of adaptations or other derivative works (https://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Diao, Shoutong
Wen, Xiaoping
Guo, Zhidong
He, Wenqiang
Deng, Haoxin
Wang, Fahui
Flame Propagation Characteristics of Syngas-Air in the Hele-Shaw Duct with Different Equivalence Ratios and Ignition Positions
title Flame Propagation Characteristics of Syngas-Air in the Hele-Shaw Duct with Different Equivalence Ratios and Ignition Positions
title_full Flame Propagation Characteristics of Syngas-Air in the Hele-Shaw Duct with Different Equivalence Ratios and Ignition Positions
title_fullStr Flame Propagation Characteristics of Syngas-Air in the Hele-Shaw Duct with Different Equivalence Ratios and Ignition Positions
title_full_unstemmed Flame Propagation Characteristics of Syngas-Air in the Hele-Shaw Duct with Different Equivalence Ratios and Ignition Positions
title_short Flame Propagation Characteristics of Syngas-Air in the Hele-Shaw Duct with Different Equivalence Ratios and Ignition Positions
title_sort flame propagation characteristics of syngas-air in the hele-shaw duct with different equivalence ratios and ignition positions
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9202038/
https://www.ncbi.nlm.nih.gov/pubmed/35721959
http://dx.doi.org/10.1021/acsomega.2c01960
work_keys_str_mv AT diaoshoutong flamepropagationcharacteristicsofsyngasairintheheleshawductwithdifferentequivalenceratiosandignitionpositions
AT wenxiaoping flamepropagationcharacteristicsofsyngasairintheheleshawductwithdifferentequivalenceratiosandignitionpositions
AT guozhidong flamepropagationcharacteristicsofsyngasairintheheleshawductwithdifferentequivalenceratiosandignitionpositions
AT hewenqiang flamepropagationcharacteristicsofsyngasairintheheleshawductwithdifferentequivalenceratiosandignitionpositions
AT denghaoxin flamepropagationcharacteristicsofsyngasairintheheleshawductwithdifferentequivalenceratiosandignitionpositions
AT wangfahui flamepropagationcharacteristicsofsyngasairintheheleshawductwithdifferentequivalenceratiosandignitionpositions