Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies
OBJECTIVE: Neonatal exposure to episodic hypoxemia and hyperoxemia is highly relevant to outcomes. Our goal was to investigate the differences in the frequency and duration of extreme low and high SpO(2) episodes between automated and manual inspired oxygen control. DESIGN: Post-hoc analysis of a co...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205075/ https://www.ncbi.nlm.nih.gov/pubmed/35715764 http://dx.doi.org/10.1186/s12887-022-03407-x |
_version_ | 1784729053284007936 |
---|---|
author | Bachman, Thomas E. Onland, Wes van Kaam, Anton H. Roubik, Karel Hummler, Helmut D. Lal, Mithilesh Lista, Gianluca Fajardo, Carlos A. |
author_facet | Bachman, Thomas E. Onland, Wes van Kaam, Anton H. Roubik, Karel Hummler, Helmut D. Lal, Mithilesh Lista, Gianluca Fajardo, Carlos A. |
author_sort | Bachman, Thomas E. |
collection | PubMed |
description | OBJECTIVE: Neonatal exposure to episodic hypoxemia and hyperoxemia is highly relevant to outcomes. Our goal was to investigate the differences in the frequency and duration of extreme low and high SpO(2) episodes between automated and manual inspired oxygen control. DESIGN: Post-hoc analysis of a cohort from prospective randomized cross-over studies. SETTING: Seven tertiary care neonatal intensive care units. PATIENTS: Fifty-eight very preterm neonates (32 or less weeks PMA) receiving respiratory support and supplemental oxygen participating in an automated versus manual oxygen control cross-over trial. MAIN MEASURES: Extreme hypoxemia was defined as a SpO(2) < 80%, extreme hyperoxemia as a SpO(2) > 98%. Episode duration was categorized as < 5 seconds, between 5 to < 30 seconds, 30 to < 60 seconds, 60 to < 120 seconds, and 120 seconds or longer. RESULTS: The infants were of a median postmenstrual age of 29 (28-31) weeks, receiving a median FiO(2) of 0.28 (0.25-0.32) with mostly receiving non-invasive respiratory support (83%). While most of the episodes were less than 30 seconds, longer episodes had a marked effect on total time exposure to extremes. The time differences in each of the three longest durations episodes (30, 60, and 120 seconds) were significantly less during automated than during manual control (p < 0.001). Nearly two-third of the reduction of total time spent at the extremes between automated and manual control (3.8 to 2.1% for < 80% SpO(2) and 3.0 to 1.6% for > 98% SpO(2)) was seen in the episodes of at least 60 seconds. CONCLUSIONS: This study shows that the majority of episodes preterm infants spent in SpO(2) extremes are of short duration regardless of manual or automated control. However, the infrequent longer episodes not only contribute the most to the total exposure, but also their reduction in frequency to the improvement associated with automated control. |
format | Online Article Text |
id | pubmed-9205075 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-92050752022-06-18 Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies Bachman, Thomas E. Onland, Wes van Kaam, Anton H. Roubik, Karel Hummler, Helmut D. Lal, Mithilesh Lista, Gianluca Fajardo, Carlos A. BMC Pediatr Research OBJECTIVE: Neonatal exposure to episodic hypoxemia and hyperoxemia is highly relevant to outcomes. Our goal was to investigate the differences in the frequency and duration of extreme low and high SpO(2) episodes between automated and manual inspired oxygen control. DESIGN: Post-hoc analysis of a cohort from prospective randomized cross-over studies. SETTING: Seven tertiary care neonatal intensive care units. PATIENTS: Fifty-eight very preterm neonates (32 or less weeks PMA) receiving respiratory support and supplemental oxygen participating in an automated versus manual oxygen control cross-over trial. MAIN MEASURES: Extreme hypoxemia was defined as a SpO(2) < 80%, extreme hyperoxemia as a SpO(2) > 98%. Episode duration was categorized as < 5 seconds, between 5 to < 30 seconds, 30 to < 60 seconds, 60 to < 120 seconds, and 120 seconds or longer. RESULTS: The infants were of a median postmenstrual age of 29 (28-31) weeks, receiving a median FiO(2) of 0.28 (0.25-0.32) with mostly receiving non-invasive respiratory support (83%). While most of the episodes were less than 30 seconds, longer episodes had a marked effect on total time exposure to extremes. The time differences in each of the three longest durations episodes (30, 60, and 120 seconds) were significantly less during automated than during manual control (p < 0.001). Nearly two-third of the reduction of total time spent at the extremes between automated and manual control (3.8 to 2.1% for < 80% SpO(2) and 3.0 to 1.6% for > 98% SpO(2)) was seen in the episodes of at least 60 seconds. CONCLUSIONS: This study shows that the majority of episodes preterm infants spent in SpO(2) extremes are of short duration regardless of manual or automated control. However, the infrequent longer episodes not only contribute the most to the total exposure, but also their reduction in frequency to the improvement associated with automated control. BioMed Central 2022-06-17 /pmc/articles/PMC9205075/ /pubmed/35715764 http://dx.doi.org/10.1186/s12887-022-03407-x Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Bachman, Thomas E. Onland, Wes van Kaam, Anton H. Roubik, Karel Hummler, Helmut D. Lal, Mithilesh Lista, Gianluca Fajardo, Carlos A. Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies |
title | Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies |
title_full | Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies |
title_fullStr | Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies |
title_full_unstemmed | Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies |
title_short | Frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies |
title_sort | frequency and duration of extreme hypoxemic and hyperoxemic episodes during manual and automatic oxygen control in preterm infants: a retrospective cohort analysis from randomized studies |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205075/ https://www.ncbi.nlm.nih.gov/pubmed/35715764 http://dx.doi.org/10.1186/s12887-022-03407-x |
work_keys_str_mv | AT bachmanthomase frequencyanddurationofextremehypoxemicandhyperoxemicepisodesduringmanualandautomaticoxygencontrolinpreterminfantsaretrospectivecohortanalysisfromrandomizedstudies AT onlandwes frequencyanddurationofextremehypoxemicandhyperoxemicepisodesduringmanualandautomaticoxygencontrolinpreterminfantsaretrospectivecohortanalysisfromrandomizedstudies AT vankaamantonh frequencyanddurationofextremehypoxemicandhyperoxemicepisodesduringmanualandautomaticoxygencontrolinpreterminfantsaretrospectivecohortanalysisfromrandomizedstudies AT roubikkarel frequencyanddurationofextremehypoxemicandhyperoxemicepisodesduringmanualandautomaticoxygencontrolinpreterminfantsaretrospectivecohortanalysisfromrandomizedstudies AT hummlerhelmutd frequencyanddurationofextremehypoxemicandhyperoxemicepisodesduringmanualandautomaticoxygencontrolinpreterminfantsaretrospectivecohortanalysisfromrandomizedstudies AT lalmithilesh frequencyanddurationofextremehypoxemicandhyperoxemicepisodesduringmanualandautomaticoxygencontrolinpreterminfantsaretrospectivecohortanalysisfromrandomizedstudies AT listagianluca frequencyanddurationofextremehypoxemicandhyperoxemicepisodesduringmanualandautomaticoxygencontrolinpreterminfantsaretrospectivecohortanalysisfromrandomizedstudies AT fajardocarlosa frequencyanddurationofextremehypoxemicandhyperoxemicepisodesduringmanualandautomaticoxygencontrolinpreterminfantsaretrospectivecohortanalysisfromrandomizedstudies |