Cargando…
Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review
Polyethylene liner dissociation (PLD) is a rare but catastrophic complication following total hip arthroplasty (THA). When it occurs in the early postoperative period, it can be easy to miss the diagnosis. Liner dissociation has been reported previously with the Pinnacle(®) (DePuy), Harris-Galante(®...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205751/ https://www.ncbi.nlm.nih.gov/pubmed/35733505 http://dx.doi.org/10.7759/cureus.25119 |
_version_ | 1784729193799483392 |
---|---|
author | Cheppalli, Naga Goel, Akshay Wassef, Audry Bhandarkar, Amit W Kakish, Samer |
author_facet | Cheppalli, Naga Goel, Akshay Wassef, Audry Bhandarkar, Amit W Kakish, Samer |
author_sort | Cheppalli, Naga |
collection | PubMed |
description | Polyethylene liner dissociation (PLD) is a rare but catastrophic complication following total hip arthroplasty (THA). When it occurs in the early postoperative period, it can be easy to miss the diagnosis. Liner dissociation has been reported previously with the Pinnacle(®) (DePuy), Harris-Galante(®) (Zimmer), and Trident(®) (Stryker) acetabular components. To the best of our knowledge, this is the first case reporting PLD in the G7(®) cup (Zimmer-Biomet). This case report, along with a review of the literature, highlights the clinical presentation, radiological imaging, treatment options, and technical tips to avoid PLD in the early postoperative period. |
format | Online Article Text |
id | pubmed-9205751 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-92057512022-06-21 Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review Cheppalli, Naga Goel, Akshay Wassef, Audry Bhandarkar, Amit W Kakish, Samer Cureus Orthopedics Polyethylene liner dissociation (PLD) is a rare but catastrophic complication following total hip arthroplasty (THA). When it occurs in the early postoperative period, it can be easy to miss the diagnosis. Liner dissociation has been reported previously with the Pinnacle(®) (DePuy), Harris-Galante(®) (Zimmer), and Trident(®) (Stryker) acetabular components. To the best of our knowledge, this is the first case reporting PLD in the G7(®) cup (Zimmer-Biomet). This case report, along with a review of the literature, highlights the clinical presentation, radiological imaging, treatment options, and technical tips to avoid PLD in the early postoperative period. Cureus 2022-05-18 /pmc/articles/PMC9205751/ /pubmed/35733505 http://dx.doi.org/10.7759/cureus.25119 Text en Copyright © 2022, Cheppalli et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Orthopedics Cheppalli, Naga Goel, Akshay Wassef, Audry Bhandarkar, Amit W Kakish, Samer Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review |
title | Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review |
title_full | Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review |
title_fullStr | Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review |
title_full_unstemmed | Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review |
title_short | Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review |
title_sort | polyethylene liner dissociation in the early post-operative period following total hip arthroplasty: a case report and literature review |
topic | Orthopedics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205751/ https://www.ncbi.nlm.nih.gov/pubmed/35733505 http://dx.doi.org/10.7759/cureus.25119 |
work_keys_str_mv | AT cheppallinaga polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview AT goelakshay polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview AT wassefaudry polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview AT bhandarkaramitw polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview AT kakishsamer polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview |