Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review

Polyethylene liner dissociation (PLD) is a rare but catastrophic complication following total hip arthroplasty (THA). When it occurs in the early postoperative period, it can be easy to miss the diagnosis. Liner dissociation has been reported previously with the Pinnacle(®) (DePuy), Harris-Galante(®...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheppalli, Naga, Goel, Akshay, Wassef, Audry, Bhandarkar, Amit W, Kakish, Samer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205751/
https://www.ncbi.nlm.nih.gov/pubmed/35733505
http://dx.doi.org/10.7759/cureus.25119
_version_ 1784729193799483392
author Cheppalli, Naga
Goel, Akshay
Wassef, Audry
Bhandarkar, Amit W
Kakish, Samer
author_facet Cheppalli, Naga
Goel, Akshay
Wassef, Audry
Bhandarkar, Amit W
Kakish, Samer
author_sort Cheppalli, Naga
collection PubMed
description Polyethylene liner dissociation (PLD) is a rare but catastrophic complication following total hip arthroplasty (THA). When it occurs in the early postoperative period, it can be easy to miss the diagnosis. Liner dissociation has been reported previously with the Pinnacle(®) (DePuy), Harris-Galante(®) (Zimmer), and Trident(®) (Stryker) acetabular components. To the best of our knowledge, this is the first case reporting PLD in the G7(®) cup (Zimmer-Biomet). This case report, along with a review of the literature, highlights the clinical presentation, radiological imaging, treatment options, and technical tips to avoid PLD in the early postoperative period.
format Online
Article
Text
id pubmed-9205751
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-92057512022-06-21 Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review Cheppalli, Naga Goel, Akshay Wassef, Audry Bhandarkar, Amit W Kakish, Samer Cureus Orthopedics Polyethylene liner dissociation (PLD) is a rare but catastrophic complication following total hip arthroplasty (THA). When it occurs in the early postoperative period, it can be easy to miss the diagnosis. Liner dissociation has been reported previously with the Pinnacle(®) (DePuy), Harris-Galante(®) (Zimmer), and Trident(®) (Stryker) acetabular components. To the best of our knowledge, this is the first case reporting PLD in the G7(®) cup (Zimmer-Biomet). This case report, along with a review of the literature, highlights the clinical presentation, radiological imaging, treatment options, and technical tips to avoid PLD in the early postoperative period. Cureus 2022-05-18 /pmc/articles/PMC9205751/ /pubmed/35733505 http://dx.doi.org/10.7759/cureus.25119 Text en Copyright © 2022, Cheppalli et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Cheppalli, Naga
Goel, Akshay
Wassef, Audry
Bhandarkar, Amit W
Kakish, Samer
Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review
title Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review
title_full Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review
title_fullStr Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review
title_full_unstemmed Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review
title_short Polyethylene Liner Dissociation in the Early Post-Operative Period Following Total Hip Arthroplasty: A Case Report and Literature Review
title_sort polyethylene liner dissociation in the early post-operative period following total hip arthroplasty: a case report and literature review
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205751/
https://www.ncbi.nlm.nih.gov/pubmed/35733505
http://dx.doi.org/10.7759/cureus.25119
work_keys_str_mv AT cheppallinaga polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview
AT goelakshay polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview
AT wassefaudry polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview
AT bhandarkaramitw polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview
AT kakishsamer polyethylenelinerdissociationintheearlypostoperativeperiodfollowingtotalhiparthroplastyacasereportandliteraturereview