Cargando…
Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study
OBJECTIVE(S): The purpose of this study was to validate undersampled single-photon emission computed tomography (SPECT) imaging using a combination of compressed sensing (CS) iterative reconstruction (CS-IR) and offset acquisition. METHODS: Three types of numerical phantoms were used to evaluate ima...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Mashhad University of Medical Sciences
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205842/ https://www.ncbi.nlm.nih.gov/pubmed/35800416 http://dx.doi.org/10.22038/AOJNMB.2021.59585.1417 |
_version_ | 1784729214648320000 |
---|---|
author | Matsutomo, Norikazu Hashimoto, Takeyuki Fukami, Mitsuha Yamamoto, Tomoaki |
author_facet | Matsutomo, Norikazu Hashimoto, Takeyuki Fukami, Mitsuha Yamamoto, Tomoaki |
author_sort | Matsutomo, Norikazu |
collection | PubMed |
description | OBJECTIVE(S): The purpose of this study was to validate undersampled single-photon emission computed tomography (SPECT) imaging using a combination of compressed sensing (CS) iterative reconstruction (CS-IR) and offset acquisition. METHODS: Three types of numerical phantoms were used to evaluate image quality and quantification derived from CS with offset acquisition. SPECT images were reconstructed using filtered back-projection (FBP), maximum likelihood-expectation maximization (ML-EM), CS-IR, and CS-IR with offset acquisition. The efficacy of CS-IR with offset acquisition was examined in terms of spatial resolution, aspect ratio (ASR), activity concentration linearity, contrast, percent coefficient of variation (%CV), and specific binding ratio (SBR). RESULTS: The full widths at half maximum remained unchanged as the number of projections decreased in CS-IR with offset acquisition. Changes in ASRs and linearities of count density were observed for ML-EM and CS-IR from undersampled projections. The %CV obtained by CS-IR with offset acquisition was substantially lower than that obtained by ML-EM and CS-IR. There were no significant differences between the %CVs obtained from 60 projections by CS-IR with offset acquisition and from 120 projections by FBP. Although the SBRs for CS-IR with offset acquisition tended to be slightly lower than for FBP, the SBRs for CS-IR with offset acquisition did not change with the number of projections. CONCLUSIONS: CS-IR with offset acquisition can provide good image quality and quantification compared with a commonly used SPECT reconstruction method, especially from undersampled projection data. Our proposed method could shorten overall SPECT acquisition times, which would benefit patients and enable quantification with dynamic SPECT acquisitions. |
format | Online Article Text |
id | pubmed-9205842 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Mashhad University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-92058422022-07-06 Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study Matsutomo, Norikazu Hashimoto, Takeyuki Fukami, Mitsuha Yamamoto, Tomoaki Asia Ocean J Nucl Med Biol Original Article OBJECTIVE(S): The purpose of this study was to validate undersampled single-photon emission computed tomography (SPECT) imaging using a combination of compressed sensing (CS) iterative reconstruction (CS-IR) and offset acquisition. METHODS: Three types of numerical phantoms were used to evaluate image quality and quantification derived from CS with offset acquisition. SPECT images were reconstructed using filtered back-projection (FBP), maximum likelihood-expectation maximization (ML-EM), CS-IR, and CS-IR with offset acquisition. The efficacy of CS-IR with offset acquisition was examined in terms of spatial resolution, aspect ratio (ASR), activity concentration linearity, contrast, percent coefficient of variation (%CV), and specific binding ratio (SBR). RESULTS: The full widths at half maximum remained unchanged as the number of projections decreased in CS-IR with offset acquisition. Changes in ASRs and linearities of count density were observed for ML-EM and CS-IR from undersampled projections. The %CV obtained by CS-IR with offset acquisition was substantially lower than that obtained by ML-EM and CS-IR. There were no significant differences between the %CVs obtained from 60 projections by CS-IR with offset acquisition and from 120 projections by FBP. Although the SBRs for CS-IR with offset acquisition tended to be slightly lower than for FBP, the SBRs for CS-IR with offset acquisition did not change with the number of projections. CONCLUSIONS: CS-IR with offset acquisition can provide good image quality and quantification compared with a commonly used SPECT reconstruction method, especially from undersampled projection data. Our proposed method could shorten overall SPECT acquisition times, which would benefit patients and enable quantification with dynamic SPECT acquisitions. Mashhad University of Medical Sciences 2022 /pmc/articles/PMC9205842/ /pubmed/35800416 http://dx.doi.org/10.22038/AOJNMB.2021.59585.1417 Text en © 2022 mums.ac.ir All rights reserved https://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/ (https://creativecommons.org/licenses/by/3.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Matsutomo, Norikazu Hashimoto, Takeyuki Fukami, Mitsuha Yamamoto, Tomoaki Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study |
title | Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study |
title_full | Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study |
title_fullStr | Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study |
title_full_unstemmed | Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study |
title_short | Combination of compressed sensing-based iterative reconstruction and offset acquisition for I-123 FP-CIT SPECT: a simulation study |
title_sort | combination of compressed sensing-based iterative reconstruction and offset acquisition for i-123 fp-cit spect: a simulation study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205842/ https://www.ncbi.nlm.nih.gov/pubmed/35800416 http://dx.doi.org/10.22038/AOJNMB.2021.59585.1417 |
work_keys_str_mv | AT matsutomonorikazu combinationofcompressedsensingbasediterativereconstructionandoffsetacquisitionfori123fpcitspectasimulationstudy AT hashimototakeyuki combinationofcompressedsensingbasediterativereconstructionandoffsetacquisitionfori123fpcitspectasimulationstudy AT fukamimitsuha combinationofcompressedsensingbasediterativereconstructionandoffsetacquisitionfori123fpcitspectasimulationstudy AT yamamototomoaki combinationofcompressedsensingbasediterativereconstructionandoffsetacquisitionfori123fpcitspectasimulationstudy |