Effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study
Colorectal endoscopic submucosal dissection (ESD) is a difficult procedure, and its introduction to trainees has been debated. Although the criteria for performing colorectal ESD vary among institutions, it is often allowed after gaining experience performing surgeries in animals and upper gastroint...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205909/ https://www.ncbi.nlm.nih.gov/pubmed/35715564 http://dx.doi.org/10.1038/s41598-022-14407-3 |
_version_ | 1784729228997033984 |
---|---|
author | Jinushi, Ryuhei Tashima, Tomoaki Terada, Rie Miyaguchi, Kazuya Katsuda, Hiromune Ogawa, Tomoya Nakano, Yuya Saito, Yoichi Fujita, Akashi Tanisaka, Yuki Mizuide, Masafumi Mashimo, Yumi Kawasaki, Tomonori Ryozawa, Shomei |
author_facet | Jinushi, Ryuhei Tashima, Tomoaki Terada, Rie Miyaguchi, Kazuya Katsuda, Hiromune Ogawa, Tomoya Nakano, Yuya Saito, Yoichi Fujita, Akashi Tanisaka, Yuki Mizuide, Masafumi Mashimo, Yumi Kawasaki, Tomonori Ryozawa, Shomei |
author_sort | Jinushi, Ryuhei |
collection | PubMed |
description | Colorectal endoscopic submucosal dissection (ESD) is a difficult procedure, and its introduction to trainees has been debated. Although the criteria for performing colorectal ESD vary among institutions, it is often allowed after gaining experience performing surgeries in animals and upper gastrointestinal ESD. This pilot study aimed to compare the treatment outcomes of ESD performed by trainees using the multi-loop traction device (MLTD group) and those of conventional ESD performed by experts (control group). It also aimed to determine whether the MLTD can be used to safely introduce colorectal ESD to trainees. We included 26 colorectal ESD patients (13 in the MLTD group and 13 in the control group) treated at our hospital from October to December 2021. There were no significant differences in the procedure time (50 min vs. 30 min), dissection speed (19.9 mm(2)/min vs. 28.7 mm(2)/min), and intraoperative perforation (0% vs. 0%) of the two groups. Furthermore, the rate of ESD self-completion in the MLTD group was 100%. Therefore, the use of the MLTD allowed the safe introduction of colorectal ESD, even among endoscopists with no experience performing colorectal ESD. Consequently, the use of the MLTD may replace animal and upper gastrointestinal ESD when introducing colorectal ESD to trainees. |
format | Online Article Text |
id | pubmed-9205909 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-92059092022-06-19 Effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study Jinushi, Ryuhei Tashima, Tomoaki Terada, Rie Miyaguchi, Kazuya Katsuda, Hiromune Ogawa, Tomoya Nakano, Yuya Saito, Yoichi Fujita, Akashi Tanisaka, Yuki Mizuide, Masafumi Mashimo, Yumi Kawasaki, Tomonori Ryozawa, Shomei Sci Rep Article Colorectal endoscopic submucosal dissection (ESD) is a difficult procedure, and its introduction to trainees has been debated. Although the criteria for performing colorectal ESD vary among institutions, it is often allowed after gaining experience performing surgeries in animals and upper gastrointestinal ESD. This pilot study aimed to compare the treatment outcomes of ESD performed by trainees using the multi-loop traction device (MLTD group) and those of conventional ESD performed by experts (control group). It also aimed to determine whether the MLTD can be used to safely introduce colorectal ESD to trainees. We included 26 colorectal ESD patients (13 in the MLTD group and 13 in the control group) treated at our hospital from October to December 2021. There were no significant differences in the procedure time (50 min vs. 30 min), dissection speed (19.9 mm(2)/min vs. 28.7 mm(2)/min), and intraoperative perforation (0% vs. 0%) of the two groups. Furthermore, the rate of ESD self-completion in the MLTD group was 100%. Therefore, the use of the MLTD allowed the safe introduction of colorectal ESD, even among endoscopists with no experience performing colorectal ESD. Consequently, the use of the MLTD may replace animal and upper gastrointestinal ESD when introducing colorectal ESD to trainees. Nature Publishing Group UK 2022-06-17 /pmc/articles/PMC9205909/ /pubmed/35715564 http://dx.doi.org/10.1038/s41598-022-14407-3 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Jinushi, Ryuhei Tashima, Tomoaki Terada, Rie Miyaguchi, Kazuya Katsuda, Hiromune Ogawa, Tomoya Nakano, Yuya Saito, Yoichi Fujita, Akashi Tanisaka, Yuki Mizuide, Masafumi Mashimo, Yumi Kawasaki, Tomonori Ryozawa, Shomei Effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study |
title | Effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study |
title_full | Effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study |
title_fullStr | Effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study |
title_full_unstemmed | Effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study |
title_short | Effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study |
title_sort | effectiveness of a multi-loop traction device for colorectal endoscopic submucosal dissection performed by trainees: a pilot study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205909/ https://www.ncbi.nlm.nih.gov/pubmed/35715564 http://dx.doi.org/10.1038/s41598-022-14407-3 |
work_keys_str_mv | AT jinushiryuhei effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT tashimatomoaki effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT teradarie effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT miyaguchikazuya effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT katsudahiromune effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT ogawatomoya effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT nakanoyuya effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT saitoyoichi effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT fujitaakashi effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT tanisakayuki effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT mizuidemasafumi effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT mashimoyumi effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT kawasakitomonori effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy AT ryozawashomei effectivenessofamultilooptractiondeviceforcolorectalendoscopicsubmucosaldissectionperformedbytraineesapilotstudy |