Cargando…

Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma

This study aimed to find out the significance of the difference between frequency-doubling technology perimetry (FDT) and standard automated perimetry (SAP) in terms of the detected visual field (VF) damage, and evaluate associated factors to SAP–FDT difference in early glaucoma. Glaucoma patients i...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Seong Ah, Park, Chan Kee, Park, Hae-Young Lopilly
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205973/
https://www.ncbi.nlm.nih.gov/pubmed/35715424
http://dx.doi.org/10.1038/s41598-022-13781-2
_version_ 1784729243772518400
author Kim, Seong Ah
Park, Chan Kee
Park, Hae-Young Lopilly
author_facet Kim, Seong Ah
Park, Chan Kee
Park, Hae-Young Lopilly
author_sort Kim, Seong Ah
collection PubMed
description This study aimed to find out the significance of the difference between frequency-doubling technology perimetry (FDT) and standard automated perimetry (SAP) in terms of the detected visual field (VF) damage, and evaluate associated factors to SAP–FDT difference in early glaucoma. Glaucoma patients in early stage (MD better than − 6.0 decibel, 96 eyes) were included in this cross-sectional study. We subtracted mean deviation (MD) and pattern standard deviation (PSD) of FDT from those of SAP, respectively. Additionally, we counted significantly depressed points of P < 5% and P < 1% on the pattern deviation probability plot of both FDT and SAP and defined eyes with significant SAP–FDT difference when the number of abnormal points were greater than 4 points on FDT. We measured lamina cribrosa depth (LCD) and lamina cribrosa curvature index (LCCI) for structural parameters of the optic nerve head from images using enhanced depth imaging of the optical coherence tomography (OCT). Peripapillary vessel density (VD) and presence of microvasculature dropout (MvD), the complete loss of choriocapillaris in localized regions of parapapillary atrophy, was evaluated using deep layer map of OCT angiography (OCT-A) for vascular parameters. Peripheral nasal step (PNS) group had an isolated glaucomatous VF defect within nasal periphery outside 10° of fixation. Parafoveal scotoma (PFS) group had an isolated glaucomatous VF defect within 12 points of a central 10˚ radius. Eyes with significant SAP–FDT difference showed higher detection of MvD on deep layer map of OCT-A, greater LCD, and greater LCCI (all P < 0.05, respectively). In logistic regression analysis, frequent presence of MvD, less presence of disc hemorrhage, and greater LCD were significantly associated with significant SAP–FDT difference. Sub-analysis was performed in eyes with PNS (50 eyes) and PFS (46 eyes). SAP–FDT difference of MD value showed positive association with peripapillary VD on deep layer of OCT-A, which was significant in eyes with PFS compared to eyes with PNS. SAP–FDT difference of PSD value showed negative association with LCCI and LCD, which was significant in eyes with PNS compared to eyes with PFS. Glaucomatous eyes classified by the difference of the detected VF damage on FDT versus SAP showed different clinical features. Greater SAP–FDT difference was significantly associated with structural parameters such as LCD and LCCI. Less SAP–FDT difference was associated with presence of disc hemorrhage and lower deep layer peripepillary VD. There is possibility to use the difference of SAP and FDT to identify associated risk factors in glaucoma patients.
format Online
Article
Text
id pubmed-9205973
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-92059732022-06-19 Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma Kim, Seong Ah Park, Chan Kee Park, Hae-Young Lopilly Sci Rep Article This study aimed to find out the significance of the difference between frequency-doubling technology perimetry (FDT) and standard automated perimetry (SAP) in terms of the detected visual field (VF) damage, and evaluate associated factors to SAP–FDT difference in early glaucoma. Glaucoma patients in early stage (MD better than − 6.0 decibel, 96 eyes) were included in this cross-sectional study. We subtracted mean deviation (MD) and pattern standard deviation (PSD) of FDT from those of SAP, respectively. Additionally, we counted significantly depressed points of P < 5% and P < 1% on the pattern deviation probability plot of both FDT and SAP and defined eyes with significant SAP–FDT difference when the number of abnormal points were greater than 4 points on FDT. We measured lamina cribrosa depth (LCD) and lamina cribrosa curvature index (LCCI) for structural parameters of the optic nerve head from images using enhanced depth imaging of the optical coherence tomography (OCT). Peripapillary vessel density (VD) and presence of microvasculature dropout (MvD), the complete loss of choriocapillaris in localized regions of parapapillary atrophy, was evaluated using deep layer map of OCT angiography (OCT-A) for vascular parameters. Peripheral nasal step (PNS) group had an isolated glaucomatous VF defect within nasal periphery outside 10° of fixation. Parafoveal scotoma (PFS) group had an isolated glaucomatous VF defect within 12 points of a central 10˚ radius. Eyes with significant SAP–FDT difference showed higher detection of MvD on deep layer map of OCT-A, greater LCD, and greater LCCI (all P < 0.05, respectively). In logistic regression analysis, frequent presence of MvD, less presence of disc hemorrhage, and greater LCD were significantly associated with significant SAP–FDT difference. Sub-analysis was performed in eyes with PNS (50 eyes) and PFS (46 eyes). SAP–FDT difference of MD value showed positive association with peripapillary VD on deep layer of OCT-A, which was significant in eyes with PFS compared to eyes with PNS. SAP–FDT difference of PSD value showed negative association with LCCI and LCD, which was significant in eyes with PNS compared to eyes with PFS. Glaucomatous eyes classified by the difference of the detected VF damage on FDT versus SAP showed different clinical features. Greater SAP–FDT difference was significantly associated with structural parameters such as LCD and LCCI. Less SAP–FDT difference was associated with presence of disc hemorrhage and lower deep layer peripepillary VD. There is possibility to use the difference of SAP and FDT to identify associated risk factors in glaucoma patients. Nature Publishing Group UK 2022-06-17 /pmc/articles/PMC9205973/ /pubmed/35715424 http://dx.doi.org/10.1038/s41598-022-13781-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Kim, Seong Ah
Park, Chan Kee
Park, Hae-Young Lopilly
Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
title Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
title_full Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
title_fullStr Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
title_full_unstemmed Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
title_short Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
title_sort comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9205973/
https://www.ncbi.nlm.nih.gov/pubmed/35715424
http://dx.doi.org/10.1038/s41598-022-13781-2
work_keys_str_mv AT kimseongah comparisonbetweenfrequencydoublingtechnologyperimetryandstandardautomatedperimetryinearlyglaucoma
AT parkchankee comparisonbetweenfrequencydoublingtechnologyperimetryandstandardautomatedperimetryinearlyglaucoma
AT parkhaeyounglopilly comparisonbetweenfrequencydoublingtechnologyperimetryandstandardautomatedperimetryinearlyglaucoma