Cargando…

An old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture: A case report

INTRODUCTION: and importance: Unicondylar tibial plateau fractures with tibial shaft fractures are extremely rare among the elderly group of people. The traditional treatment method is to apply double plates to fix unicondylar tibial plateau fractures combined with tibial shaft fractures respectivel...

Descripción completa

Detalles Bibliográficos
Autores principales: Lv, Zhengming, Ji, Tianyi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9207132/
https://www.ncbi.nlm.nih.gov/pubmed/35734728
http://dx.doi.org/10.1016/j.amsu.2022.103927
_version_ 1784729450912415744
author Lv, Zhengming
Ji, Tianyi
author_facet Lv, Zhengming
Ji, Tianyi
author_sort Lv, Zhengming
collection PubMed
description INTRODUCTION: and importance: Unicondylar tibial plateau fractures with tibial shaft fractures are extremely rare among the elderly group of people. The traditional treatment method is to apply double plates to fix unicondylar tibial plateau fractures combined with tibial shaft fractures respectively, but this fixation method can disrupt the blood supply around the soft tissues and increase the rate of postoperative infection and fracture non-union. In this paper, we would analyse an old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture which admitted to our department and discussed the efficacy of using intramedullary nails and plates in the treatment of these fractures. CASE PRESENTATION: A 78-year-old woman with an old unicondylar tibial plateau fracture combined with tibial shaft fracture was presented in this case. Using an intramedullary nail combined with a plate to achieve good results. CLINICAL DISCUSSION: This case represents a rare case of an unicondylar tibial plateau fracture with a tibial shaft fracture. In this case, the tibial plateau fracture was first incised and internally fixed with a 9-hole plate across the fracture line of the tibial shaft, followed by fixing the tibial shaft fracture with an intramedullary nail. This treatment helped us successfully reset the unicondylar tibial plateau fracture with tibial shaft fracture and provided a satisfactory outcome for the patient. CONCLUSION: Using intramedullary nails combined with plates to treat unicondylar tibial plateau fractures with tibial shaft fractures allowed for a predictable healing result.
format Online
Article
Text
id pubmed-9207132
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-92071322022-06-21 An old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture: A case report Lv, Zhengming Ji, Tianyi Ann Med Surg (Lond) Case Report INTRODUCTION: and importance: Unicondylar tibial plateau fractures with tibial shaft fractures are extremely rare among the elderly group of people. The traditional treatment method is to apply double plates to fix unicondylar tibial plateau fractures combined with tibial shaft fractures respectively, but this fixation method can disrupt the blood supply around the soft tissues and increase the rate of postoperative infection and fracture non-union. In this paper, we would analyse an old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture which admitted to our department and discussed the efficacy of using intramedullary nails and plates in the treatment of these fractures. CASE PRESENTATION: A 78-year-old woman with an old unicondylar tibial plateau fracture combined with tibial shaft fracture was presented in this case. Using an intramedullary nail combined with a plate to achieve good results. CLINICAL DISCUSSION: This case represents a rare case of an unicondylar tibial plateau fracture with a tibial shaft fracture. In this case, the tibial plateau fracture was first incised and internally fixed with a 9-hole plate across the fracture line of the tibial shaft, followed by fixing the tibial shaft fracture with an intramedullary nail. This treatment helped us successfully reset the unicondylar tibial plateau fracture with tibial shaft fracture and provided a satisfactory outcome for the patient. CONCLUSION: Using intramedullary nails combined with plates to treat unicondylar tibial plateau fractures with tibial shaft fractures allowed for a predictable healing result. Elsevier 2022-06-04 /pmc/articles/PMC9207132/ /pubmed/35734728 http://dx.doi.org/10.1016/j.amsu.2022.103927 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Lv, Zhengming
Ji, Tianyi
An old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture: A case report
title An old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture: A case report
title_full An old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture: A case report
title_fullStr An old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture: A case report
title_full_unstemmed An old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture: A case report
title_short An old unicondylar tibial plateau fracture (Schatzker type III) with tibial shaft fracture: A case report
title_sort old unicondylar tibial plateau fracture (schatzker type iii) with tibial shaft fracture: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9207132/
https://www.ncbi.nlm.nih.gov/pubmed/35734728
http://dx.doi.org/10.1016/j.amsu.2022.103927
work_keys_str_mv AT lvzhengming anoldunicondylartibialplateaufractureschatzkertypeiiiwithtibialshaftfractureacasereport
AT jitianyi anoldunicondylartibialplateaufractureschatzkertypeiiiwithtibialshaftfractureacasereport
AT lvzhengming oldunicondylartibialplateaufractureschatzkertypeiiiwithtibialshaftfractureacasereport
AT jitianyi oldunicondylartibialplateaufractureschatzkertypeiiiwithtibialshaftfractureacasereport