Evaluation of linear lesion formation and thermodynamics by dragging ablation with the third-generation laser balloon

BACKGROUND: The lesion formation properties of a motorized rotational delivery (RAPID) mode, third-generation laser balloon (LB3) ablation compared to point-by-point laser ablation in patients with atrial fibrillation remain unclear. OBJECTIVE: The purpose of this study was to assess lesion characte...

Descripción completa

Detalles Bibliográficos
Autores principales: Nagase, Takahiko, Asano, So, Fukunaga, Hiroshi, Kasai, Yuhei, Inoue, Kanki, Sekiguchi, Yukio, Tanizaki, Kohei, Murai, Tatsuya, Nanasato, Mamoru, Umemura, Jun, Nitta, Junichi, Isobe, Mitsuaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9207738/
https://www.ncbi.nlm.nih.gov/pubmed/35734297
http://dx.doi.org/10.1016/j.hroo.2022.04.001
Descripción
Sumario:BACKGROUND: The lesion formation properties of a motorized rotational delivery (RAPID) mode, third-generation laser balloon (LB3) ablation compared to point-by-point laser ablation in patients with atrial fibrillation remain unclear. OBJECTIVE: The purpose of this study was to assess lesion characteristics and thermodynamics in LB3 ablation with a RAPID mode in vitro model. METHODS: Chicken muscles were cauterized using LB3 in RAPID mode with 13 W and 15 W and 50% overlapped point-by-point fashion with 7 W/30 seconds, 8.5 W/20 seconds, 10 W/20 seconds, and 12 W/20 seconds. Lesion depth, width, and continuity were compared. Lesion continuity was classified by the visible gap degree categorized from 1 (perfect) to 3 (poor). Thermodynamics and maximum tissue temperatures were assessed under infrared thermographic monitoring. Fifteen and 5 lesions were evaluated per ablation protocol for measurement of lesion size and continuity and for thermographic assessment, respectively. RESULTS: Lesion depth and width were smaller in RAPID mode laser ablation than point-by-point laser ablation (P <.001). However, RAPID mode laser ablation revealed sufficient mean lesion depth of 5 mm or more. Lesion continuity was 1 (perfect) in all samples in RAPID mode laser ablation and point-by-point laser ablation (P = 1). Infrared thermographic observation demonstrated fast and gapless linear lesion formation with thermal stacking in RAPID mode laser ablation. Maximum tissue temperature was lower in RAPID mode laser ablation than point-by-point laser ablation (P <.001). CONCLUSION: RAPID mode LB3 ablation could provide fast, gapless, and acceptable lesion formation with thermal stacking and moderate tissue temperature rise.