Cargando…

464 A Novel High Dose Rate Brachytherapy Device for Preventing Local Recurrence of Pancreatic Cancer Dosimetry Verification

OBJECTIVES/GOALS: To demonstrate safety and limit damage to off-target organs, we will be determining dosimetry parameters through experimentation and Monte Carlo simulations with our brachy therapy applicator designed to improve upon current designs to treat a 3-dimensional volume. METHODS/STUDY PO...

Descripción completa

Detalles Bibliográficos
Autores principales: Verma, Rohan, Detels, Kelsey, Hoopes, Mary, Mohseni, Niam, Shumyeko, Dema, Yazdi, Youseph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9209287/
http://dx.doi.org/10.1017/cts.2022.272
_version_ 1784729918659100672
author Verma, Rohan
Detels, Kelsey
Hoopes, Mary
Mohseni, Niam
Shumyeko, Dema
Yazdi, Youseph
author_facet Verma, Rohan
Detels, Kelsey
Hoopes, Mary
Mohseni, Niam
Shumyeko, Dema
Yazdi, Youseph
author_sort Verma, Rohan
collection PubMed
description OBJECTIVES/GOALS: To demonstrate safety and limit damage to off-target organs, we will be determining dosimetry parameters through experimentation and Monte Carlo simulations with our brachy therapy applicator designed to improve upon current designs to treat a 3-dimensional volume. METHODS/STUDY POPULATION: Low-cost materials were used to manufacture our High Dose Rate (HDR) applicator and a readily available after loading system was used to load our configuration with a radioactive source. The dosimetry of our device was analyzed using commercially available software and external beam therapy films to generate depth dose profiles and superficial dose distribution. Additionally, we attempt to confirm Task Group No. 43 (TG-43) dosimetry parameters using Monte Carlo simulations for our device. These data were compared with currently available applicators used for intraoperative radiotherapy. RESULTS/ANTICIPATED RESULTS: We anticipate that we will be able to validate dosimetry parameters for our device in preparation for clinical use. We aim to show our dose distributions align well with proposed target volumes while considering the composition and shape of our applicator. We hope to demonstrate that, unlike current applicators, our design is more effective at treating a 3-dimensional target volume. DISCUSSION/SIGNIFICANCE: By 2040, pancreatic cancer will be the second-largest cause of cancer-related deaths. Even with current brachytherapy applicators, 30-40% of pancreatic cancer seems to recur near the surgical site after surgery. By preventing local recurrence, we hope to improve patient outcomes.
format Online
Article
Text
id pubmed-9209287
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-92092872022-07-01 464 A Novel High Dose Rate Brachytherapy Device for Preventing Local Recurrence of Pancreatic Cancer Dosimetry Verification Verma, Rohan Detels, Kelsey Hoopes, Mary Mohseni, Niam Shumyeko, Dema Yazdi, Youseph J Clin Transl Sci Valued Approaches OBJECTIVES/GOALS: To demonstrate safety and limit damage to off-target organs, we will be determining dosimetry parameters through experimentation and Monte Carlo simulations with our brachy therapy applicator designed to improve upon current designs to treat a 3-dimensional volume. METHODS/STUDY POPULATION: Low-cost materials were used to manufacture our High Dose Rate (HDR) applicator and a readily available after loading system was used to load our configuration with a radioactive source. The dosimetry of our device was analyzed using commercially available software and external beam therapy films to generate depth dose profiles and superficial dose distribution. Additionally, we attempt to confirm Task Group No. 43 (TG-43) dosimetry parameters using Monte Carlo simulations for our device. These data were compared with currently available applicators used for intraoperative radiotherapy. RESULTS/ANTICIPATED RESULTS: We anticipate that we will be able to validate dosimetry parameters for our device in preparation for clinical use. We aim to show our dose distributions align well with proposed target volumes while considering the composition and shape of our applicator. We hope to demonstrate that, unlike current applicators, our design is more effective at treating a 3-dimensional target volume. DISCUSSION/SIGNIFICANCE: By 2040, pancreatic cancer will be the second-largest cause of cancer-related deaths. Even with current brachytherapy applicators, 30-40% of pancreatic cancer seems to recur near the surgical site after surgery. By preventing local recurrence, we hope to improve patient outcomes. Cambridge University Press 2022-04-19 /pmc/articles/PMC9209287/ http://dx.doi.org/10.1017/cts.2022.272 Text en © The Association for Clinical and Translational Science 2022 https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is unaltered and is properly cited. The written permission of Cambridge University Press must be obtained for commercial re-use or in order to create a derivative work.
spellingShingle Valued Approaches
Verma, Rohan
Detels, Kelsey
Hoopes, Mary
Mohseni, Niam
Shumyeko, Dema
Yazdi, Youseph
464 A Novel High Dose Rate Brachytherapy Device for Preventing Local Recurrence of Pancreatic Cancer Dosimetry Verification
title 464 A Novel High Dose Rate Brachytherapy Device for Preventing Local Recurrence of Pancreatic Cancer Dosimetry Verification
title_full 464 A Novel High Dose Rate Brachytherapy Device for Preventing Local Recurrence of Pancreatic Cancer Dosimetry Verification
title_fullStr 464 A Novel High Dose Rate Brachytherapy Device for Preventing Local Recurrence of Pancreatic Cancer Dosimetry Verification
title_full_unstemmed 464 A Novel High Dose Rate Brachytherapy Device for Preventing Local Recurrence of Pancreatic Cancer Dosimetry Verification
title_short 464 A Novel High Dose Rate Brachytherapy Device for Preventing Local Recurrence of Pancreatic Cancer Dosimetry Verification
title_sort 464 a novel high dose rate brachytherapy device for preventing local recurrence of pancreatic cancer dosimetry verification
topic Valued Approaches
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9209287/
http://dx.doi.org/10.1017/cts.2022.272
work_keys_str_mv AT vermarohan 464anovelhighdoseratebrachytherapydeviceforpreventinglocalrecurrenceofpancreaticcancerdosimetryverification
AT detelskelsey 464anovelhighdoseratebrachytherapydeviceforpreventinglocalrecurrenceofpancreaticcancerdosimetryverification
AT hoopesmary 464anovelhighdoseratebrachytherapydeviceforpreventinglocalrecurrenceofpancreaticcancerdosimetryverification
AT mohseniniam 464anovelhighdoseratebrachytherapydeviceforpreventinglocalrecurrenceofpancreaticcancerdosimetryverification
AT shumyekodema 464anovelhighdoseratebrachytherapydeviceforpreventinglocalrecurrenceofpancreaticcancerdosimetryverification
AT yazdiyouseph 464anovelhighdoseratebrachytherapydeviceforpreventinglocalrecurrenceofpancreaticcancerdosimetryverification