Cargando…

370 Developing a Digitally Integrated Endotracheal Tube for Neonates to Improve Safety and Respiratory Function

OBJECTIVES/GOALS: Neonatal endotracheal tubes (ETTs) are usually uncuffed to avoid subglottic stenosis and other complications, but cuffed ETTs allow better ventilation. Our goal was to detect and control pressure in the cuff below the limit of occluding venous flow to minimize the risk of subglotti...

Descripción completa

Detalles Bibliográficos
Autores principales: Nienaber, Thomas, Perez, Sarah, Stephenson, Krista, Sanford, Joseph, Abella, Adria, Jensen, Morten, Sexton, Kevin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9209300/
http://dx.doi.org/10.1017/cts.2022.210
_version_ 1784729921967357952
author Nienaber, Thomas
Perez, Sarah
Stephenson, Krista
Sanford, Joseph
Abella, Adria
Jensen, Morten
Sexton, Kevin
author_facet Nienaber, Thomas
Perez, Sarah
Stephenson, Krista
Sanford, Joseph
Abella, Adria
Jensen, Morten
Sexton, Kevin
author_sort Nienaber, Thomas
collection PubMed
description OBJECTIVES/GOALS: Neonatal endotracheal tubes (ETTs) are usually uncuffed to avoid subglottic stenosis and other complications, but cuffed ETTs allow better ventilation. Our goal was to detect and control pressure in the cuff below the limit of occluding venous flow to minimize the risk of subglottic stenosis. METHODS/STUDY POPULATION: We designed a pressure sensor to fit on a 2.5 ETT for prototype testing in 8 age adult female rabbits. Eight uncuffed age- and sex- matched rabbits served as control. Study duration was 2 hours during which pressure in the cuff was limited by novel sensor (intervention) or auscultation (control). Anesthesia was maintained with sevoflurane. Ventilation was provided mechanically. Subsequently the tracheae were removed, sectioned crosswise, and compared histologically for mucosal damage. RESULTS/ANTICIPATED RESULTS: Preliminary data demonstrated an almost 30% greater amount of intact mucosa in the intervention group. The sensor also provided data on heart rate and respiratory rate, although this signal was not optimal. After filing an invention disclosure and provisional patent, we are refining our device to include multiple compartments for local control of cuff pressure and applying for a STTR Phase I/II application. DISCUSSION/SIGNIFICANCE: Ventilation in neonates with uncuffed ETTs can be suboptimal due to leak around the tube, but cuffed ETTs pose the threat of subglottic stenosis and other complications. We have designed a prototype cuffed ETT with a sensor to maintain low cuff pressure while preventing leaks and largely avoiding damage to the tracheal mucosa.
format Online
Article
Text
id pubmed-9209300
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-92093002022-07-01 370 Developing a Digitally Integrated Endotracheal Tube for Neonates to Improve Safety and Respiratory Function Nienaber, Thomas Perez, Sarah Stephenson, Krista Sanford, Joseph Abella, Adria Jensen, Morten Sexton, Kevin J Clin Transl Sci Valued Approaches OBJECTIVES/GOALS: Neonatal endotracheal tubes (ETTs) are usually uncuffed to avoid subglottic stenosis and other complications, but cuffed ETTs allow better ventilation. Our goal was to detect and control pressure in the cuff below the limit of occluding venous flow to minimize the risk of subglottic stenosis. METHODS/STUDY POPULATION: We designed a pressure sensor to fit on a 2.5 ETT for prototype testing in 8 age adult female rabbits. Eight uncuffed age- and sex- matched rabbits served as control. Study duration was 2 hours during which pressure in the cuff was limited by novel sensor (intervention) or auscultation (control). Anesthesia was maintained with sevoflurane. Ventilation was provided mechanically. Subsequently the tracheae were removed, sectioned crosswise, and compared histologically for mucosal damage. RESULTS/ANTICIPATED RESULTS: Preliminary data demonstrated an almost 30% greater amount of intact mucosa in the intervention group. The sensor also provided data on heart rate and respiratory rate, although this signal was not optimal. After filing an invention disclosure and provisional patent, we are refining our device to include multiple compartments for local control of cuff pressure and applying for a STTR Phase I/II application. DISCUSSION/SIGNIFICANCE: Ventilation in neonates with uncuffed ETTs can be suboptimal due to leak around the tube, but cuffed ETTs pose the threat of subglottic stenosis and other complications. We have designed a prototype cuffed ETT with a sensor to maintain low cuff pressure while preventing leaks and largely avoiding damage to the tracheal mucosa. Cambridge University Press 2022-04-19 /pmc/articles/PMC9209300/ http://dx.doi.org/10.1017/cts.2022.210 Text en © The Association for Clinical and Translational Science 2022 https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is unaltered and is properly cited. The written permission of Cambridge University Press must be obtained for commercial re-use or in order to create a derivative work.
spellingShingle Valued Approaches
Nienaber, Thomas
Perez, Sarah
Stephenson, Krista
Sanford, Joseph
Abella, Adria
Jensen, Morten
Sexton, Kevin
370 Developing a Digitally Integrated Endotracheal Tube for Neonates to Improve Safety and Respiratory Function
title 370 Developing a Digitally Integrated Endotracheal Tube for Neonates to Improve Safety and Respiratory Function
title_full 370 Developing a Digitally Integrated Endotracheal Tube for Neonates to Improve Safety and Respiratory Function
title_fullStr 370 Developing a Digitally Integrated Endotracheal Tube for Neonates to Improve Safety and Respiratory Function
title_full_unstemmed 370 Developing a Digitally Integrated Endotracheal Tube for Neonates to Improve Safety and Respiratory Function
title_short 370 Developing a Digitally Integrated Endotracheal Tube for Neonates to Improve Safety and Respiratory Function
title_sort 370 developing a digitally integrated endotracheal tube for neonates to improve safety and respiratory function
topic Valued Approaches
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9209300/
http://dx.doi.org/10.1017/cts.2022.210
work_keys_str_mv AT nienaberthomas 370developingadigitallyintegratedendotrachealtubeforneonatestoimprovesafetyandrespiratoryfunction
AT perezsarah 370developingadigitallyintegratedendotrachealtubeforneonatestoimprovesafetyandrespiratoryfunction
AT stephensonkrista 370developingadigitallyintegratedendotrachealtubeforneonatestoimprovesafetyandrespiratoryfunction
AT sanfordjoseph 370developingadigitallyintegratedendotrachealtubeforneonatestoimprovesafetyandrespiratoryfunction
AT abellaadria 370developingadigitallyintegratedendotrachealtubeforneonatestoimprovesafetyandrespiratoryfunction
AT jensenmorten 370developingadigitallyintegratedendotrachealtubeforneonatestoimprovesafetyandrespiratoryfunction
AT sextonkevin 370developingadigitallyintegratedendotrachealtubeforneonatestoimprovesafetyandrespiratoryfunction