Cargando…

Improving the Robustness of Human-Machine Interactive Control for Myoelectric Prosthetic Hand During Arm Position Changing

Robust classification of natural hand grasp type based on electromyography (EMG) still has some shortcomings in the practical prosthetic hand control, owing to the influence of dynamic arm position changing during hand actions. This study provided a framework for robust hand grasp type classificatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Ke, Ang, Huang, Jian, Wang, Jing, He, Jiping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9211066/
https://www.ncbi.nlm.nih.gov/pubmed/35747073
http://dx.doi.org/10.3389/fnbot.2022.853773
_version_ 1784730283112660992
author Ke, Ang
Huang, Jian
Wang, Jing
He, Jiping
author_facet Ke, Ang
Huang, Jian
Wang, Jing
He, Jiping
author_sort Ke, Ang
collection PubMed
description Robust classification of natural hand grasp type based on electromyography (EMG) still has some shortcomings in the practical prosthetic hand control, owing to the influence of dynamic arm position changing during hand actions. This study provided a framework for robust hand grasp type classification during dynamic arm position changes, improving both the “hardware” and “algorithm” components. In the hardware aspect, co-located synchronous EMG and force myography (FMG) signals are adopted as the multi-modal strategy. In the algorithm aspect, a sequential decision algorithm is proposed by combining the RNN-based deep learning model with a knowledge-based post-processing model. Experimental results showed that the classification accuracy of multi-modal EMG-FMG signals was increased by more than 10% compared with the EMG-only signal. Moreover, the classification accuracy of the proposed sequential decision algorithm improved the accuracy by more than 4% compared with other baseline models when using both EMG and FMG signals.
format Online
Article
Text
id pubmed-9211066
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-92110662022-06-22 Improving the Robustness of Human-Machine Interactive Control for Myoelectric Prosthetic Hand During Arm Position Changing Ke, Ang Huang, Jian Wang, Jing He, Jiping Front Neurorobot Neuroscience Robust classification of natural hand grasp type based on electromyography (EMG) still has some shortcomings in the practical prosthetic hand control, owing to the influence of dynamic arm position changing during hand actions. This study provided a framework for robust hand grasp type classification during dynamic arm position changes, improving both the “hardware” and “algorithm” components. In the hardware aspect, co-located synchronous EMG and force myography (FMG) signals are adopted as the multi-modal strategy. In the algorithm aspect, a sequential decision algorithm is proposed by combining the RNN-based deep learning model with a knowledge-based post-processing model. Experimental results showed that the classification accuracy of multi-modal EMG-FMG signals was increased by more than 10% compared with the EMG-only signal. Moreover, the classification accuracy of the proposed sequential decision algorithm improved the accuracy by more than 4% compared with other baseline models when using both EMG and FMG signals. Frontiers Media S.A. 2022-06-07 /pmc/articles/PMC9211066/ /pubmed/35747073 http://dx.doi.org/10.3389/fnbot.2022.853773 Text en Copyright © 2022 Ke, Huang, Wang and He. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neuroscience
Ke, Ang
Huang, Jian
Wang, Jing
He, Jiping
Improving the Robustness of Human-Machine Interactive Control for Myoelectric Prosthetic Hand During Arm Position Changing
title Improving the Robustness of Human-Machine Interactive Control for Myoelectric Prosthetic Hand During Arm Position Changing
title_full Improving the Robustness of Human-Machine Interactive Control for Myoelectric Prosthetic Hand During Arm Position Changing
title_fullStr Improving the Robustness of Human-Machine Interactive Control for Myoelectric Prosthetic Hand During Arm Position Changing
title_full_unstemmed Improving the Robustness of Human-Machine Interactive Control for Myoelectric Prosthetic Hand During Arm Position Changing
title_short Improving the Robustness of Human-Machine Interactive Control for Myoelectric Prosthetic Hand During Arm Position Changing
title_sort improving the robustness of human-machine interactive control for myoelectric prosthetic hand during arm position changing
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9211066/
https://www.ncbi.nlm.nih.gov/pubmed/35747073
http://dx.doi.org/10.3389/fnbot.2022.853773
work_keys_str_mv AT keang improvingtherobustnessofhumanmachineinteractivecontrolformyoelectricprosthetichandduringarmpositionchanging
AT huangjian improvingtherobustnessofhumanmachineinteractivecontrolformyoelectricprosthetichandduringarmpositionchanging
AT wangjing improvingtherobustnessofhumanmachineinteractivecontrolformyoelectricprosthetichandduringarmpositionchanging
AT hejiping improvingtherobustnessofhumanmachineinteractivecontrolformyoelectricprosthetichandduringarmpositionchanging