Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT
INTRODUCTION: Dosimetric and radiobiological evaluations for the Jaws-only Intensity-modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity-modulated radiation therapy (JO-IMRT) and 3D conformal radiation therapy (3D-CRT). To compare the head-and-neck therapeutic approaches...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213241/ https://www.ncbi.nlm.nih.gov/pubmed/35754762 http://dx.doi.org/10.1016/j.sjbs.2022.103336 |
_version_ | 1784730795739447296 |
---|---|
author | Tai, Duong Thanh Oanh, Luong Thi Phuong, Pham Hoai Sulieman, Abdelmoneim Abolaban, Fouad A. Omer, Hiba Chow, James C.L. |
author_facet | Tai, Duong Thanh Oanh, Luong Thi Phuong, Pham Hoai Sulieman, Abdelmoneim Abolaban, Fouad A. Omer, Hiba Chow, James C.L. |
author_sort | Tai, Duong Thanh |
collection | PubMed |
description | INTRODUCTION: Dosimetric and radiobiological evaluations for the Jaws-only Intensity-modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity-modulated radiation therapy (JO-IMRT) and 3D conformal radiation therapy (3D-CRT). To compare the head-and-neck therapeutic approaches utilizing JO-IMRT and 3D-CRT techniques, different radiation dose indices were calculated, including: conformity index (CI), homogeneity index (HI), and radiobiological variables like Niemierko's equivalent uniform dose based tumor control probability (TCP) of planning target volume (PTV), normal tissue complication probability (NTCP) of organs at risk (OAR) (brainstem, spinal cord, and parotid grand). MATERIALS AND METHODS: Twenty-five nasopharynx patients were studied using the Prowess Panther Treatment Planning System (Prowess Inc). The results were compared with the dose distribution obtained using 3D-CRT. RESULTS: Regarding tumor coverage and CI, JO-IMRT showed better results than 3D-CRT. The average doses received by the PTVs were quite similar: 72.1 ± 0.8 Gy by 3D-CRT and 72.5 ± 0.6 Gy by JO-IMRT plans (p > 0.05). The mean doses received by the parotid gland were 56.7 ± 0.7 Gy by 3D-CRT and 26.8 ± 0.3 Gy by JO-IMRT (p > 0.05). The HI and CI were 0.13 ± 0.01 and 0.14 ± 0.05 and (p > 0.05) by 3D-CRT and 0.83 ± 0.05 and 0.73 ± 0.10 by JO-IMRT (p < 0.05). The average TCP of PTV was 0.82 ± 0.08 by 3D-CRT and 0.92 ± 0.02 by JO-IMRT. Moreover, the NTCP of the parotid glands, brain stem, and spinal cord were lower using the JO-IMRT than 3D-CRT plans. In comparison to the 3D-CRT approach, the JO-IMRT technique was able to boost dose coverage to the PTV, improve the target's CI and HI, and spare the parotid glands. This suggests the power of the JO-IMRT over 3D-CRT in head-and-neck radiotherapy. |
format | Online Article Text |
id | pubmed-9213241 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-92132412022-06-23 Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT Tai, Duong Thanh Oanh, Luong Thi Phuong, Pham Hoai Sulieman, Abdelmoneim Abolaban, Fouad A. Omer, Hiba Chow, James C.L. Saudi J Biol Sci Original Article INTRODUCTION: Dosimetric and radiobiological evaluations for the Jaws-only Intensity-modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity-modulated radiation therapy (JO-IMRT) and 3D conformal radiation therapy (3D-CRT). To compare the head-and-neck therapeutic approaches utilizing JO-IMRT and 3D-CRT techniques, different radiation dose indices were calculated, including: conformity index (CI), homogeneity index (HI), and radiobiological variables like Niemierko's equivalent uniform dose based tumor control probability (TCP) of planning target volume (PTV), normal tissue complication probability (NTCP) of organs at risk (OAR) (brainstem, spinal cord, and parotid grand). MATERIALS AND METHODS: Twenty-five nasopharynx patients were studied using the Prowess Panther Treatment Planning System (Prowess Inc). The results were compared with the dose distribution obtained using 3D-CRT. RESULTS: Regarding tumor coverage and CI, JO-IMRT showed better results than 3D-CRT. The average doses received by the PTVs were quite similar: 72.1 ± 0.8 Gy by 3D-CRT and 72.5 ± 0.6 Gy by JO-IMRT plans (p > 0.05). The mean doses received by the parotid gland were 56.7 ± 0.7 Gy by 3D-CRT and 26.8 ± 0.3 Gy by JO-IMRT (p > 0.05). The HI and CI were 0.13 ± 0.01 and 0.14 ± 0.05 and (p > 0.05) by 3D-CRT and 0.83 ± 0.05 and 0.73 ± 0.10 by JO-IMRT (p < 0.05). The average TCP of PTV was 0.82 ± 0.08 by 3D-CRT and 0.92 ± 0.02 by JO-IMRT. Moreover, the NTCP of the parotid glands, brain stem, and spinal cord were lower using the JO-IMRT than 3D-CRT plans. In comparison to the 3D-CRT approach, the JO-IMRT technique was able to boost dose coverage to the PTV, improve the target's CI and HI, and spare the parotid glands. This suggests the power of the JO-IMRT over 3D-CRT in head-and-neck radiotherapy. Elsevier 2022-08 2022-06-02 /pmc/articles/PMC9213241/ /pubmed/35754762 http://dx.doi.org/10.1016/j.sjbs.2022.103336 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Article Tai, Duong Thanh Oanh, Luong Thi Phuong, Pham Hoai Sulieman, Abdelmoneim Abolaban, Fouad A. Omer, Hiba Chow, James C.L. Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT |
title | Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT |
title_full | Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT |
title_fullStr | Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT |
title_full_unstemmed | Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT |
title_short | Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT |
title_sort | dosimetric and radiobiological comparison in head-and-neck radiotherapy using jo-imrt and 3d-crt |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213241/ https://www.ncbi.nlm.nih.gov/pubmed/35754762 http://dx.doi.org/10.1016/j.sjbs.2022.103336 |
work_keys_str_mv | AT taiduongthanh dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt AT oanhluongthi dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt AT phuongphamhoai dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt AT suliemanabdelmoneim dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt AT abolabanfouada dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt AT omerhiba dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt AT chowjamescl dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt |