Cargando…

Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT

INTRODUCTION: Dosimetric and radiobiological evaluations for the Jaws-only Intensity-modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity-modulated radiation therapy (JO-IMRT) and 3D conformal radiation therapy (3D-CRT). To compare the head-and-neck therapeutic approaches...

Descripción completa

Detalles Bibliográficos
Autores principales: Tai, Duong Thanh, Oanh, Luong Thi, Phuong, Pham Hoai, Sulieman, Abdelmoneim, Abolaban, Fouad A., Omer, Hiba, Chow, James C.L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213241/
https://www.ncbi.nlm.nih.gov/pubmed/35754762
http://dx.doi.org/10.1016/j.sjbs.2022.103336
_version_ 1784730795739447296
author Tai, Duong Thanh
Oanh, Luong Thi
Phuong, Pham Hoai
Sulieman, Abdelmoneim
Abolaban, Fouad A.
Omer, Hiba
Chow, James C.L.
author_facet Tai, Duong Thanh
Oanh, Luong Thi
Phuong, Pham Hoai
Sulieman, Abdelmoneim
Abolaban, Fouad A.
Omer, Hiba
Chow, James C.L.
author_sort Tai, Duong Thanh
collection PubMed
description INTRODUCTION: Dosimetric and radiobiological evaluations for the Jaws-only Intensity-modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity-modulated radiation therapy (JO-IMRT) and 3D conformal radiation therapy (3D-CRT). To compare the head-and-neck therapeutic approaches utilizing JO-IMRT and 3D-CRT techniques, different radiation dose indices were calculated, including: conformity index (CI), homogeneity index (HI), and radiobiological variables like Niemierko's equivalent uniform dose based tumor control probability (TCP) of planning target volume (PTV), normal tissue complication probability (NTCP) of organs at risk (OAR) (brainstem, spinal cord, and parotid grand). MATERIALS AND METHODS: Twenty-five nasopharynx patients were studied using the Prowess Panther Treatment Planning System (Prowess Inc). The results were compared with the dose distribution obtained using 3D-CRT. RESULTS: Regarding tumor coverage and CI, JO-IMRT showed better results than 3D-CRT. The average doses received by the PTVs were quite similar: 72.1 ± 0.8 Gy by 3D-CRT and 72.5 ± 0.6 Gy by JO-IMRT plans (p > 0.05). The mean doses received by the parotid gland were 56.7 ± 0.7 Gy by 3D-CRT and 26.8 ± 0.3 Gy by JO-IMRT (p > 0.05). The HI and CI were 0.13 ± 0.01 and 0.14 ± 0.05 and (p > 0.05) by 3D-CRT and 0.83 ± 0.05 and 0.73 ± 0.10 by JO-IMRT (p < 0.05). The average TCP of PTV was 0.82 ± 0.08 by 3D-CRT and 0.92 ± 0.02 by JO-IMRT. Moreover, the NTCP of the parotid glands, brain stem, and spinal cord were lower using the JO-IMRT than 3D-CRT plans. In comparison to the 3D-CRT approach, the JO-IMRT technique was able to boost dose coverage to the PTV, improve the target's CI and HI, and spare the parotid glands. This suggests the power of the JO-IMRT over 3D-CRT in head-and-neck radiotherapy.
format Online
Article
Text
id pubmed-9213241
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-92132412022-06-23 Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT Tai, Duong Thanh Oanh, Luong Thi Phuong, Pham Hoai Sulieman, Abdelmoneim Abolaban, Fouad A. Omer, Hiba Chow, James C.L. Saudi J Biol Sci Original Article INTRODUCTION: Dosimetric and radiobiological evaluations for the Jaws-only Intensity-modulated radiotherapy (JO-IMRT) technique for head and neck jaws-only intensity-modulated radiation therapy (JO-IMRT) and 3D conformal radiation therapy (3D-CRT). To compare the head-and-neck therapeutic approaches utilizing JO-IMRT and 3D-CRT techniques, different radiation dose indices were calculated, including: conformity index (CI), homogeneity index (HI), and radiobiological variables like Niemierko's equivalent uniform dose based tumor control probability (TCP) of planning target volume (PTV), normal tissue complication probability (NTCP) of organs at risk (OAR) (brainstem, spinal cord, and parotid grand). MATERIALS AND METHODS: Twenty-five nasopharynx patients were studied using the Prowess Panther Treatment Planning System (Prowess Inc). The results were compared with the dose distribution obtained using 3D-CRT. RESULTS: Regarding tumor coverage and CI, JO-IMRT showed better results than 3D-CRT. The average doses received by the PTVs were quite similar: 72.1 ± 0.8 Gy by 3D-CRT and 72.5 ± 0.6 Gy by JO-IMRT plans (p > 0.05). The mean doses received by the parotid gland were 56.7 ± 0.7 Gy by 3D-CRT and 26.8 ± 0.3 Gy by JO-IMRT (p > 0.05). The HI and CI were 0.13 ± 0.01 and 0.14 ± 0.05 and (p > 0.05) by 3D-CRT and 0.83 ± 0.05 and 0.73 ± 0.10 by JO-IMRT (p < 0.05). The average TCP of PTV was 0.82 ± 0.08 by 3D-CRT and 0.92 ± 0.02 by JO-IMRT. Moreover, the NTCP of the parotid glands, brain stem, and spinal cord were lower using the JO-IMRT than 3D-CRT plans. In comparison to the 3D-CRT approach, the JO-IMRT technique was able to boost dose coverage to the PTV, improve the target's CI and HI, and spare the parotid glands. This suggests the power of the JO-IMRT over 3D-CRT in head-and-neck radiotherapy. Elsevier 2022-08 2022-06-02 /pmc/articles/PMC9213241/ /pubmed/35754762 http://dx.doi.org/10.1016/j.sjbs.2022.103336 Text en © 2022 The Author(s) https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Original Article
Tai, Duong Thanh
Oanh, Luong Thi
Phuong, Pham Hoai
Sulieman, Abdelmoneim
Abolaban, Fouad A.
Omer, Hiba
Chow, James C.L.
Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT
title Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT
title_full Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT
title_fullStr Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT
title_full_unstemmed Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT
title_short Dosimetric and radiobiological comparison in head-and-neck radiotherapy using JO-IMRT and 3D-CRT
title_sort dosimetric and radiobiological comparison in head-and-neck radiotherapy using jo-imrt and 3d-crt
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213241/
https://www.ncbi.nlm.nih.gov/pubmed/35754762
http://dx.doi.org/10.1016/j.sjbs.2022.103336
work_keys_str_mv AT taiduongthanh dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt
AT oanhluongthi dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt
AT phuongphamhoai dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt
AT suliemanabdelmoneim dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt
AT abolabanfouada dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt
AT omerhiba dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt
AT chowjamescl dosimetricandradiobiologicalcomparisoninheadandneckradiotherapyusingjoimrtand3dcrt