Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery

Background and aim Raised intracranial pressure (ICP) can be estimated by various invasive as well as non-invasive techniques. Optic nerve sheath diameter (ONSD ) is a bedside non-invasive technique for assessment of ICP as a regular follow-up tool and has added advantage over CT scan/MRI, which req...

Descripción completa

Detalles Bibliográficos
Autores principales: Chopra, Akhilendra, Das, Praveen K, Parashar, Samiksha, Misra, Shilpi, Tripathi, Manoj, Malviya, Deepak, Singh, Deepak
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213298/
https://www.ncbi.nlm.nih.gov/pubmed/35747017
http://dx.doi.org/10.7759/cureus.25200
_version_ 1784730811359035392
author Chopra, Akhilendra
Das, Praveen K
Parashar, Samiksha
Misra, Shilpi
Tripathi, Manoj
Malviya, Deepak
Singh, Deepak
author_facet Chopra, Akhilendra
Das, Praveen K
Parashar, Samiksha
Misra, Shilpi
Tripathi, Manoj
Malviya, Deepak
Singh, Deepak
author_sort Chopra, Akhilendra
collection PubMed
description Background and aim Raised intracranial pressure (ICP) can be estimated by various invasive as well as non-invasive techniques. Optic nerve sheath diameter (ONSD ) is a bedside non-invasive technique for assessment of ICP as a regular follow-up tool and has added advantage over CT scan/MRI, which require patient transfer to the suite. Cerebrospinal fluid (CSF) diversion procedures such as a ventriculoperitoneal shunt or external ventricular drainage are commonly done to relieve symptoms of patients with raised ICP. Change in ICP measured through ONSD after CSF diversion procedures may guide the proper functioning of the shunt and immediate post-operative management. The present study was conducted to compare ONSD before and after CSF diversion procedures and correlate the ONSD with ICP. Our secondary objective was to determine the ONSD cutoff for the prediction of ICP >20mm Hg. Setting, design, and methods This prospective, comparative, and observational study was carried out at Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India. The present study was conducted on 40 adult patients undergoing CSF diversion surgery under general anaesthesia. Ultrasonographic measurement of the ONSD was performed before induction, after induction, after endotracheal intubation, after completion of shunt surgery, and then every two hours for 12 hours. The direct ICP was measured by the neurosurgeon at the time of the initial ventricular puncture. Statistical analysis The Wilcoxon signed-rank test was used to compare pre and post variables. Qualitative variables were compared using the Chi-Square test/Fisher’s exact test as appropriate. Spearman's rho statistical measure of linear association was applied to measure the strength of linear association between parameters to show how close the points lie to a straight line. A p-value of <0.05 was considered statistically significant. Results The mean value of ONSD before induction and after induction was 6.36 ± 0.61 mm and 6.29 ±0.64 mm, respectively. After endotracheal intubation, ONSD slightly increased to 6.34 ±0.62mm, followed by a consistent decrease in ONSD values. The mean direct ICP recorded was 30.93±6.22 mmHg. Comparison of mean ONSD before induction, after induction, and after intubation with ONSD after surgery was statistically significant (p <0.001). We found a strong positive correlation between direct ICP and ONSD after intubation with a correlation coefficient of 0.969 (P <0.001). Receiver operating characteristic (ROC) curve analysis showed an ONSD cutoff of >5.85, predicted ICP>20 mmHg with a sensitivity of 92.3%, and specificity of 85.7%. Conclusion Measurement of ONSD by ultrasonography is an important and reliable tool in the assessment of normalization of ICP post CSF diversion procedure.
format Online
Article
Text
id pubmed-9213298
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-92132982022-06-22 Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery Chopra, Akhilendra Das, Praveen K Parashar, Samiksha Misra, Shilpi Tripathi, Manoj Malviya, Deepak Singh, Deepak Cureus Anesthesiology Background and aim Raised intracranial pressure (ICP) can be estimated by various invasive as well as non-invasive techniques. Optic nerve sheath diameter (ONSD ) is a bedside non-invasive technique for assessment of ICP as a regular follow-up tool and has added advantage over CT scan/MRI, which require patient transfer to the suite. Cerebrospinal fluid (CSF) diversion procedures such as a ventriculoperitoneal shunt or external ventricular drainage are commonly done to relieve symptoms of patients with raised ICP. Change in ICP measured through ONSD after CSF diversion procedures may guide the proper functioning of the shunt and immediate post-operative management. The present study was conducted to compare ONSD before and after CSF diversion procedures and correlate the ONSD with ICP. Our secondary objective was to determine the ONSD cutoff for the prediction of ICP >20mm Hg. Setting, design, and methods This prospective, comparative, and observational study was carried out at Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India. The present study was conducted on 40 adult patients undergoing CSF diversion surgery under general anaesthesia. Ultrasonographic measurement of the ONSD was performed before induction, after induction, after endotracheal intubation, after completion of shunt surgery, and then every two hours for 12 hours. The direct ICP was measured by the neurosurgeon at the time of the initial ventricular puncture. Statistical analysis The Wilcoxon signed-rank test was used to compare pre and post variables. Qualitative variables were compared using the Chi-Square test/Fisher’s exact test as appropriate. Spearman's rho statistical measure of linear association was applied to measure the strength of linear association between parameters to show how close the points lie to a straight line. A p-value of <0.05 was considered statistically significant. Results The mean value of ONSD before induction and after induction was 6.36 ± 0.61 mm and 6.29 ±0.64 mm, respectively. After endotracheal intubation, ONSD slightly increased to 6.34 ±0.62mm, followed by a consistent decrease in ONSD values. The mean direct ICP recorded was 30.93±6.22 mmHg. Comparison of mean ONSD before induction, after induction, and after intubation with ONSD after surgery was statistically significant (p <0.001). We found a strong positive correlation between direct ICP and ONSD after intubation with a correlation coefficient of 0.969 (P <0.001). Receiver operating characteristic (ROC) curve analysis showed an ONSD cutoff of >5.85, predicted ICP>20 mmHg with a sensitivity of 92.3%, and specificity of 85.7%. Conclusion Measurement of ONSD by ultrasonography is an important and reliable tool in the assessment of normalization of ICP post CSF diversion procedure. Cureus 2022-05-22 /pmc/articles/PMC9213298/ /pubmed/35747017 http://dx.doi.org/10.7759/cureus.25200 Text en Copyright © 2022, Chopra et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Anesthesiology
Chopra, Akhilendra
Das, Praveen K
Parashar, Samiksha
Misra, Shilpi
Tripathi, Manoj
Malviya, Deepak
Singh, Deepak
Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery
title Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery
title_full Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery
title_fullStr Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery
title_full_unstemmed Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery
title_short Clinical Relevance of Transorbital Ultrasonographic Measurement of Optic Nerve Sheath Diameter (ONSD) for Estimation of Intracranial Pressure Following Cerebrospinal Fluid Diversion Surgery
title_sort clinical relevance of transorbital ultrasonographic measurement of optic nerve sheath diameter (onsd) for estimation of intracranial pressure following cerebrospinal fluid diversion surgery
topic Anesthesiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213298/
https://www.ncbi.nlm.nih.gov/pubmed/35747017
http://dx.doi.org/10.7759/cureus.25200
work_keys_str_mv AT chopraakhilendra clinicalrelevanceoftransorbitalultrasonographicmeasurementofopticnervesheathdiameteronsdforestimationofintracranialpressurefollowingcerebrospinalfluiddiversionsurgery
AT daspraveenk clinicalrelevanceoftransorbitalultrasonographicmeasurementofopticnervesheathdiameteronsdforestimationofintracranialpressurefollowingcerebrospinalfluiddiversionsurgery
AT parasharsamiksha clinicalrelevanceoftransorbitalultrasonographicmeasurementofopticnervesheathdiameteronsdforestimationofintracranialpressurefollowingcerebrospinalfluiddiversionsurgery
AT misrashilpi clinicalrelevanceoftransorbitalultrasonographicmeasurementofopticnervesheathdiameteronsdforestimationofintracranialpressurefollowingcerebrospinalfluiddiversionsurgery
AT tripathimanoj clinicalrelevanceoftransorbitalultrasonographicmeasurementofopticnervesheathdiameteronsdforestimationofintracranialpressurefollowingcerebrospinalfluiddiversionsurgery
AT malviyadeepak clinicalrelevanceoftransorbitalultrasonographicmeasurementofopticnervesheathdiameteronsdforestimationofintracranialpressurefollowingcerebrospinalfluiddiversionsurgery
AT singhdeepak clinicalrelevanceoftransorbitalultrasonographicmeasurementofopticnervesheathdiameteronsdforestimationofintracranialpressurefollowingcerebrospinalfluiddiversionsurgery