Cargando…

Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network

BACKGROUND: Technological advances have recently made possible the estimation of maximal oxygen consumption (VO(2max)) by consumer wearables. However, the validity of such estimations has not been systematically summarized using meta-analytic methods and there are no standards guiding the validation...

Descripción completa

Detalles Bibliográficos
Autores principales: Molina-Garcia, Pablo, Notbohm, Hannah L., Schumann, Moritz, Argent, Rob, Hetherington-Rauth, Megan, Stang, Julie, Bloch, Wilhelm, Cheng, Sulin, Ekelund, Ulf, Sardinha, Luis B., Caulfield, Brian, Brønd, Jan Christian, Grøntved, Anders, Ortega, Francisco B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213394/
https://www.ncbi.nlm.nih.gov/pubmed/35072942
http://dx.doi.org/10.1007/s40279-021-01639-y
_version_ 1784730833480843264
author Molina-Garcia, Pablo
Notbohm, Hannah L.
Schumann, Moritz
Argent, Rob
Hetherington-Rauth, Megan
Stang, Julie
Bloch, Wilhelm
Cheng, Sulin
Ekelund, Ulf
Sardinha, Luis B.
Caulfield, Brian
Brønd, Jan Christian
Grøntved, Anders
Ortega, Francisco B.
author_facet Molina-Garcia, Pablo
Notbohm, Hannah L.
Schumann, Moritz
Argent, Rob
Hetherington-Rauth, Megan
Stang, Julie
Bloch, Wilhelm
Cheng, Sulin
Ekelund, Ulf
Sardinha, Luis B.
Caulfield, Brian
Brønd, Jan Christian
Grøntved, Anders
Ortega, Francisco B.
author_sort Molina-Garcia, Pablo
collection PubMed
description BACKGROUND: Technological advances have recently made possible the estimation of maximal oxygen consumption (VO(2max)) by consumer wearables. However, the validity of such estimations has not been systematically summarized using meta-analytic methods and there are no standards guiding the validation protocols. OBJECTIVE: The aim was to (1) quantitatively summarize previous studies investigating the validity of the VO(2max) estimated by consumer wearables and (2) provide best-practice recommendations for future validation studies. METHODS: First, we conducted a systematic review and meta-analysis of studies validating the estimation of VO(2max) by wearables. Second, based on the state of knowledge (derived from the systematic review) combined with the expert discussion between the members of the Towards Intelligent Health and Well-Being Network of Physical Activity Assessment (INTERLIVE) consortium, we provided a set of best-practice recommendations for validation protocols. RESULTS: Fourteen validation studies were included in the systematic review and meta-analysis. Meta-analysis results revealed that wearables using resting condition information in their algorithms significantly overestimated VO(2max) (bias 2.17 ml·kg(−1)·min(−1); limits of agreement − 13.07 to 17.41 ml·kg(−1)·min(−1)), while devices using exercise-based information in their algorithms showed a lower systematic and random error (bias − 0.09 ml·kg(−1)·min(−1); limits of agreement − 9.92 to 9.74 ml·kg(−1)·min(−1)). The INTERLIVE consortium proposed six key domains to be considered for validating wearable devices estimating VO(2max), concerning the following: the target population, reference standard, index measure, testing conditions, data processing, and statistical analysis. CONCLUSIONS: Our meta-analysis suggests that the estimations of VO(2max) by wearables that use exercise-based algorithms provide higher accuracy than those based on resting conditions. The exercise-based estimation seems to be optimal for measuring VO(2max) at the population level, yet the estimation error at the individual level is large, and, therefore, for sport/clinical purposes these methods still need improvement. The INTERLIVE network hereby provides best-practice recommendations to be used in future protocols to move towards a more accurate, transparent and comparable validation of VO(2max) derived from wearables. PROSPERO ID: CRD42021246192. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40279-021-01639-y.
format Online
Article
Text
id pubmed-9213394
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-92133942022-06-23 Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network Molina-Garcia, Pablo Notbohm, Hannah L. Schumann, Moritz Argent, Rob Hetherington-Rauth, Megan Stang, Julie Bloch, Wilhelm Cheng, Sulin Ekelund, Ulf Sardinha, Luis B. Caulfield, Brian Brønd, Jan Christian Grøntved, Anders Ortega, Francisco B. Sports Med Systematic Review BACKGROUND: Technological advances have recently made possible the estimation of maximal oxygen consumption (VO(2max)) by consumer wearables. However, the validity of such estimations has not been systematically summarized using meta-analytic methods and there are no standards guiding the validation protocols. OBJECTIVE: The aim was to (1) quantitatively summarize previous studies investigating the validity of the VO(2max) estimated by consumer wearables and (2) provide best-practice recommendations for future validation studies. METHODS: First, we conducted a systematic review and meta-analysis of studies validating the estimation of VO(2max) by wearables. Second, based on the state of knowledge (derived from the systematic review) combined with the expert discussion between the members of the Towards Intelligent Health and Well-Being Network of Physical Activity Assessment (INTERLIVE) consortium, we provided a set of best-practice recommendations for validation protocols. RESULTS: Fourteen validation studies were included in the systematic review and meta-analysis. Meta-analysis results revealed that wearables using resting condition information in their algorithms significantly overestimated VO(2max) (bias 2.17 ml·kg(−1)·min(−1); limits of agreement − 13.07 to 17.41 ml·kg(−1)·min(−1)), while devices using exercise-based information in their algorithms showed a lower systematic and random error (bias − 0.09 ml·kg(−1)·min(−1); limits of agreement − 9.92 to 9.74 ml·kg(−1)·min(−1)). The INTERLIVE consortium proposed six key domains to be considered for validating wearable devices estimating VO(2max), concerning the following: the target population, reference standard, index measure, testing conditions, data processing, and statistical analysis. CONCLUSIONS: Our meta-analysis suggests that the estimations of VO(2max) by wearables that use exercise-based algorithms provide higher accuracy than those based on resting conditions. The exercise-based estimation seems to be optimal for measuring VO(2max) at the population level, yet the estimation error at the individual level is large, and, therefore, for sport/clinical purposes these methods still need improvement. The INTERLIVE network hereby provides best-practice recommendations to be used in future protocols to move towards a more accurate, transparent and comparable validation of VO(2max) derived from wearables. PROSPERO ID: CRD42021246192. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s40279-021-01639-y. Springer International Publishing 2022-01-24 2022 /pmc/articles/PMC9213394/ /pubmed/35072942 http://dx.doi.org/10.1007/s40279-021-01639-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Systematic Review
Molina-Garcia, Pablo
Notbohm, Hannah L.
Schumann, Moritz
Argent, Rob
Hetherington-Rauth, Megan
Stang, Julie
Bloch, Wilhelm
Cheng, Sulin
Ekelund, Ulf
Sardinha, Luis B.
Caulfield, Brian
Brønd, Jan Christian
Grøntved, Anders
Ortega, Francisco B.
Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network
title Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network
title_full Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network
title_fullStr Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network
title_full_unstemmed Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network
title_short Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-analysis and Expert Statement of the INTERLIVE Network
title_sort validity of estimating the maximal oxygen consumption by consumer wearables: a systematic review with meta-analysis and expert statement of the interlive network
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213394/
https://www.ncbi.nlm.nih.gov/pubmed/35072942
http://dx.doi.org/10.1007/s40279-021-01639-y
work_keys_str_mv AT molinagarciapablo validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT notbohmhannahl validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT schumannmoritz validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT argentrob validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT hetheringtonrauthmegan validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT stangjulie validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT blochwilhelm validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT chengsulin validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT ekelundulf validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT sardinhaluisb validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT caulfieldbrian validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT brøndjanchristian validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT grøntvedanders validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork
AT ortegafranciscob validityofestimatingthemaximaloxygenconsumptionbyconsumerwearablesasystematicreviewwithmetaanalysisandexpertstatementoftheinterlivenetwork