PURPOSE: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model. METHODS: This retrospective study inclu...
Autores principales: | , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213697/ https://www.ncbi.nlm.nih.gov/pubmed/35757233 http://dx.doi.org/10.1016/j.ejro.2022.100427 |
_version_ | 1784730893187809280 |
---|---|
author | Koch, Vitali Loos, Gerald Gruenewald, Leon D. Eichler, Katrin Booz, Christian D’Angelo, Tommaso Yel, Ibrahim Mahmoudi, Scherwin Martin, Simon S. Harth, Marc Albrecht, Moritz H. Zangos, Stephan Bernatz, Simon Thalhammer, Axel Scholtz, Jan-Erik Vogl, Thomas J. Gruber-Rouh, Tatjana |
author_facet | Koch, Vitali Loos, Gerald Gruenewald, Leon D. Eichler, Katrin Booz, Christian D’Angelo, Tommaso Yel, Ibrahim Mahmoudi, Scherwin Martin, Simon S. Harth, Marc Albrecht, Moritz H. Zangos, Stephan Bernatz, Simon Thalhammer, Axel Scholtz, Jan-Erik Vogl, Thomas J. Gruber-Rouh, Tatjana |
author_sort | Koch, Vitali |
collection | PubMed |
description | PURPOSE: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model. METHODS: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation. RESULTS: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon. CONCLUSIONS: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair. |
format | Online Article Text |
id | pubmed-9213697 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-92136972022-06-23 Comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms Koch, Vitali Loos, Gerald Gruenewald, Leon D. Eichler, Katrin Booz, Christian D’Angelo, Tommaso Yel, Ibrahim Mahmoudi, Scherwin Martin, Simon S. Harth, Marc Albrecht, Moritz H. Zangos, Stephan Bernatz, Simon Thalhammer, Axel Scholtz, Jan-Erik Vogl, Thomas J. Gruber-Rouh, Tatjana Eur J Radiol Open Article PURPOSE: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model. METHODS: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation. RESULTS: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon. CONCLUSIONS: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair. Elsevier 2022-06-16 /pmc/articles/PMC9213697/ /pubmed/35757233 http://dx.doi.org/10.1016/j.ejro.2022.100427 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Koch, Vitali Loos, Gerald Gruenewald, Leon D. Eichler, Katrin Booz, Christian D’Angelo, Tommaso Yel, Ibrahim Mahmoudi, Scherwin Martin, Simon S. Harth, Marc Albrecht, Moritz H. Zangos, Stephan Bernatz, Simon Thalhammer, Axel Scholtz, Jan-Erik Vogl, Thomas J. Gruber-Rouh, Tatjana Comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms |
title | Comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms |
title_full | Comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms |
title_fullStr | Comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms |
title_full_unstemmed | Comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms |
title_short | Comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms |
title_sort | comprehensive comparison of three different workstations for accurate planning of endovascular stent implantation in patients with thoracic aortic aneurysms |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213697/ https://www.ncbi.nlm.nih.gov/pubmed/35757233 http://dx.doi.org/10.1016/j.ejro.2022.100427 |
work_keys_str_mv | AT kochvitali comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT loosgerald comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT gruenewaldleond comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT eichlerkatrin comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT boozchristian comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT dangelotommaso comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT yelibrahim comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT mahmoudischerwin comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT martinsimons comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT harthmarc comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT albrechtmoritzh comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT zangosstephan comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT bernatzsimon comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT thalhammeraxel comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT scholtzjanerik comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT voglthomasj comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms AT gruberrouhtatjana comprehensivecomparisonofthreedifferentworkstationsforaccurateplanningofendovascularstentimplantationinpatientswiththoracicaorticaneurysms |