Application of intracavitary ECG for positioning the totally implantable venous access port in the upper arm of cancer patients
Accurate positioning of the catheter tip is one of the most critical procedures in central venous catheter insertion. The traditional surface measurement method frequently has a large deviation and increases the X-ray exposure of doctors and patients. In the present retrospective study, cancer patie...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9214596/ https://www.ncbi.nlm.nih.gov/pubmed/35761811 http://dx.doi.org/10.3892/etm.2022.11404 |
_version_ | 1784731052710821888 |
---|---|
author | Shi, Lihua Chen, Huihui Yang, Yaping Li, Huifen Zhang, Jianfang |
author_facet | Shi, Lihua Chen, Huihui Yang, Yaping Li, Huifen Zhang, Jianfang |
author_sort | Shi, Lihua |
collection | PubMed |
description | Accurate positioning of the catheter tip is one of the most critical procedures in central venous catheter insertion. The traditional surface measurement method frequently has a large deviation and increases the X-ray exposure of doctors and patients. In the present retrospective study, cancer patients who received a totally implantable venous access port (TIVAP) in the upper arm using intracavitary electrocardiogram (ECG) guidance were compared with those where the traditional surface measurement method was used in terms of the rate of correct placement of the catheter tip, the rate of achieving the best position, the operation time and the complications. The results indicated that the correct placement rate and the best position rate of the catheter tip at the first attempt were higher in the ECG-guided group than in the traditional surface measurement method group (95.65 vs. 82.91% and 90.58 vs. 68.38%, respectively). The mean operation time was shorter in the ECG-guided group than in the surface measurement group (46.28 vs. 63.26 min). The incidence of complications in the ECG-guided group was 6.52%, while that in the surface measurement group was 10.26%. This indicated that the intracavitary ECG-guided tip positioning technique may improve the accuracy of tip catheter placement and shorten the operation time, thus reducing ionizing radiation caused by repeated positioning. Therefore, the intracavitary ECG-guided tip positioning technique is able to effectively place the tip of the TIVAD in the upper arm, holding great promise as a clinical application. |
format | Online Article Text |
id | pubmed-9214596 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-92145962022-06-26 Application of intracavitary ECG for positioning the totally implantable venous access port in the upper arm of cancer patients Shi, Lihua Chen, Huihui Yang, Yaping Li, Huifen Zhang, Jianfang Exp Ther Med Articles Accurate positioning of the catheter tip is one of the most critical procedures in central venous catheter insertion. The traditional surface measurement method frequently has a large deviation and increases the X-ray exposure of doctors and patients. In the present retrospective study, cancer patients who received a totally implantable venous access port (TIVAP) in the upper arm using intracavitary electrocardiogram (ECG) guidance were compared with those where the traditional surface measurement method was used in terms of the rate of correct placement of the catheter tip, the rate of achieving the best position, the operation time and the complications. The results indicated that the correct placement rate and the best position rate of the catheter tip at the first attempt were higher in the ECG-guided group than in the traditional surface measurement method group (95.65 vs. 82.91% and 90.58 vs. 68.38%, respectively). The mean operation time was shorter in the ECG-guided group than in the surface measurement group (46.28 vs. 63.26 min). The incidence of complications in the ECG-guided group was 6.52%, while that in the surface measurement group was 10.26%. This indicated that the intracavitary ECG-guided tip positioning technique may improve the accuracy of tip catheter placement and shorten the operation time, thus reducing ionizing radiation caused by repeated positioning. Therefore, the intracavitary ECG-guided tip positioning technique is able to effectively place the tip of the TIVAD in the upper arm, holding great promise as a clinical application. D.A. Spandidos 2022-06-01 /pmc/articles/PMC9214596/ /pubmed/35761811 http://dx.doi.org/10.3892/etm.2022.11404 Text en Copyright: © Shi et al. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Articles Shi, Lihua Chen, Huihui Yang, Yaping Li, Huifen Zhang, Jianfang Application of intracavitary ECG for positioning the totally implantable venous access port in the upper arm of cancer patients |
title | Application of intracavitary ECG for positioning the totally implantable venous access port in the upper arm of cancer patients |
title_full | Application of intracavitary ECG for positioning the totally implantable venous access port in the upper arm of cancer patients |
title_fullStr | Application of intracavitary ECG for positioning the totally implantable venous access port in the upper arm of cancer patients |
title_full_unstemmed | Application of intracavitary ECG for positioning the totally implantable venous access port in the upper arm of cancer patients |
title_short | Application of intracavitary ECG for positioning the totally implantable venous access port in the upper arm of cancer patients |
title_sort | application of intracavitary ecg for positioning the totally implantable venous access port in the upper arm of cancer patients |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9214596/ https://www.ncbi.nlm.nih.gov/pubmed/35761811 http://dx.doi.org/10.3892/etm.2022.11404 |
work_keys_str_mv | AT shilihua applicationofintracavitaryecgforpositioningthetotallyimplantablevenousaccessportintheupperarmofcancerpatients AT chenhuihui applicationofintracavitaryecgforpositioningthetotallyimplantablevenousaccessportintheupperarmofcancerpatients AT yangyaping applicationofintracavitaryecgforpositioningthetotallyimplantablevenousaccessportintheupperarmofcancerpatients AT lihuifen applicationofintracavitaryecgforpositioningthetotallyimplantablevenousaccessportintheupperarmofcancerpatients AT zhangjianfang applicationofintracavitaryecgforpositioningthetotallyimplantablevenousaccessportintheupperarmofcancerpatients |