Cargando…
10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance
BACKGROUND: The impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation. MET...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9215259/ https://www.ncbi.nlm.nih.gov/pubmed/35757343 http://dx.doi.org/10.3389/fcvm.2022.924958 |
_version_ | 1784731172340760576 |
---|---|
author | Scotti, Andrea Fovino, Luca Nai Coisne, Augustin Fabris, Tommaso Cardaioli, Francesco Massussi, Mauro Rodinò, Giulio Barolo, Alberto Boiago, Mauro Continisio, Saverio Montonati, Carolina Sciarretta, Tommaso Zuccarelli, Vittorio Bernardini, Valentina Masiero, Giulia Napodano, Massimo Fraccaro, Chiara Marchese, Alfredo Esposito, Giovanni Granada, Juan F. Latib, Azeem Iliceto, Sabino Tarantini, Giuseppe |
author_facet | Scotti, Andrea Fovino, Luca Nai Coisne, Augustin Fabris, Tommaso Cardaioli, Francesco Massussi, Mauro Rodinò, Giulio Barolo, Alberto Boiago, Mauro Continisio, Saverio Montonati, Carolina Sciarretta, Tommaso Zuccarelli, Vittorio Bernardini, Valentina Masiero, Giulia Napodano, Massimo Fraccaro, Chiara Marchese, Alfredo Esposito, Giovanni Granada, Juan F. Latib, Azeem Iliceto, Sabino Tarantini, Giuseppe |
author_sort | Scotti, Andrea |
collection | PubMed |
description | BACKGROUND: The impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation. METHODS: Consecutive patients with at least 5-years follow-up following TAVR for severe symptomatic aortic stenosis from June 2007 to December 2016 were included. Bioprosthetic valve failure (BVF) and hemodynamic valve deterioration (HVD) were defined according to VARC-3 updated definitions and estimated using cumulative incidence function to account for the competing risk of death. RESULTS: A total of 604 patients (82 years; 53% female) were analyzed and divided into IA (482) and SA (122) groups. Overall survival rates at 10-years were similar (IA 15%, 95%CI: 10–22; SA 11%, 95%CI: 6–20; p = 0.21). Compared to the SA TAVR, mean transaortic gradients were significantly higher and increased over time in the IA group. IA TAVRs showed higher 10-year cumulative incidences of BVF (IA 8% vs. SA 1%, p = 0.02) and severe HVD (IA 5% vs. SA 1%, p = 0.05). The occurrence of BVF and HVD in the IA group occurred primarily in the smallest TAVR devices (20–23-mm). After excluding these sizes, the cumulative incidences of BVF (IA 5% vs. SA 1%, p = 0.40) and severe HVD (IA 2% vs. SA 1%, p = 0.11) were similar. CONCLUSION: In this study, TAVR leaflet design had no impact on survival at 10-years. IA devices showed higher transaortic gradients and cumulative incidences of HVD and BVF predominantly occurring in the smallest valve sizes. |
format | Online Article Text |
id | pubmed-9215259 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-92152592022-06-23 10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance Scotti, Andrea Fovino, Luca Nai Coisne, Augustin Fabris, Tommaso Cardaioli, Francesco Massussi, Mauro Rodinò, Giulio Barolo, Alberto Boiago, Mauro Continisio, Saverio Montonati, Carolina Sciarretta, Tommaso Zuccarelli, Vittorio Bernardini, Valentina Masiero, Giulia Napodano, Massimo Fraccaro, Chiara Marchese, Alfredo Esposito, Giovanni Granada, Juan F. Latib, Azeem Iliceto, Sabino Tarantini, Giuseppe Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: The impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation. METHODS: Consecutive patients with at least 5-years follow-up following TAVR for severe symptomatic aortic stenosis from June 2007 to December 2016 were included. Bioprosthetic valve failure (BVF) and hemodynamic valve deterioration (HVD) were defined according to VARC-3 updated definitions and estimated using cumulative incidence function to account for the competing risk of death. RESULTS: A total of 604 patients (82 years; 53% female) were analyzed and divided into IA (482) and SA (122) groups. Overall survival rates at 10-years were similar (IA 15%, 95%CI: 10–22; SA 11%, 95%CI: 6–20; p = 0.21). Compared to the SA TAVR, mean transaortic gradients were significantly higher and increased over time in the IA group. IA TAVRs showed higher 10-year cumulative incidences of BVF (IA 8% vs. SA 1%, p = 0.02) and severe HVD (IA 5% vs. SA 1%, p = 0.05). The occurrence of BVF and HVD in the IA group occurred primarily in the smallest TAVR devices (20–23-mm). After excluding these sizes, the cumulative incidences of BVF (IA 5% vs. SA 1%, p = 0.40) and severe HVD (IA 2% vs. SA 1%, p = 0.11) were similar. CONCLUSION: In this study, TAVR leaflet design had no impact on survival at 10-years. IA devices showed higher transaortic gradients and cumulative incidences of HVD and BVF predominantly occurring in the smallest valve sizes. Frontiers Media S.A. 2022-06-08 /pmc/articles/PMC9215259/ /pubmed/35757343 http://dx.doi.org/10.3389/fcvm.2022.924958 Text en Copyright © 2022 Scotti, Fovino, Coisne, Fabris, Cardaioli, Massussi, Rodinò, Barolo, Boiago, Continisio, Montonati, Sciarretta, Zuccarelli, Bernardini, Masiero, Napodano, Fraccaro, Marchese, Esposito, Granada, Latib, Iliceto and Tarantini. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Scotti, Andrea Fovino, Luca Nai Coisne, Augustin Fabris, Tommaso Cardaioli, Francesco Massussi, Mauro Rodinò, Giulio Barolo, Alberto Boiago, Mauro Continisio, Saverio Montonati, Carolina Sciarretta, Tommaso Zuccarelli, Vittorio Bernardini, Valentina Masiero, Giulia Napodano, Massimo Fraccaro, Chiara Marchese, Alfredo Esposito, Giovanni Granada, Juan F. Latib, Azeem Iliceto, Sabino Tarantini, Giuseppe 10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance |
title | 10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance |
title_full | 10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance |
title_fullStr | 10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance |
title_full_unstemmed | 10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance |
title_short | 10-Year Impact of Transcatheter Aortic Valve Replacement Leaflet Design (Intra- Versus Supra-Annular) in Mortality and Hemodynamic Performance |
title_sort | 10-year impact of transcatheter aortic valve replacement leaflet design (intra- versus supra-annular) in mortality and hemodynamic performance |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9215259/ https://www.ncbi.nlm.nih.gov/pubmed/35757343 http://dx.doi.org/10.3389/fcvm.2022.924958 |
work_keys_str_mv | AT scottiandrea 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT fovinolucanai 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT coisneaugustin 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT fabristommaso 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT cardaiolifrancesco 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT massussimauro 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT rodinogiulio 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT baroloalberto 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT boiagomauro 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT continisiosaverio 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT montonaticarolina 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT sciarrettatommaso 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT zuccarellivittorio 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT bernardinivalentina 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT masierogiulia 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT napodanomassimo 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT fraccarochiara 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT marchesealfredo 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT espositogiovanni 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT granadajuanf 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT latibazeem 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT ilicetosabino 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance AT tarantinigiuseppe 10yearimpactoftranscatheteraorticvalvereplacementleafletdesignintraversussupraannularinmortalityandhemodynamicperformance |