Cargando…

Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps

Minimally invasive surgery (MIS) incorporates surgical instruments through small incisions to perform procedures. Despite the potential advantages of MIS, the lack of tactile sensation and haptic feedback due to the indirect contact between the surgeon’s hands and the tissues restricts sensing the s...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9216325/
https://www.ncbi.nlm.nih.gov/pubmed/35774413
http://dx.doi.org/10.1109/JTEHM.2022.3180937
_version_ 1784731396157210624
collection PubMed
description Minimally invasive surgery (MIS) incorporates surgical instruments through small incisions to perform procedures. Despite the potential advantages of MIS, the lack of tactile sensation and haptic feedback due to the indirect contact between the surgeon’s hands and the tissues restricts sensing the strength of applied forces or obtaining information about the biomechanical properties of tissues under operation. Accordingly, there is a crucial need for intelligent systems to provide an artificial tactile sensation to MIS surgeons and trainees. This study evaluates the potential of our proposed real-time grasping forces and deformation angles feedback to assist surgeons in detecting tissues’ stiffness. A prototype was developed using a standard laparoscopic grasper integrated with a force-sensitive resistor on one grasping jaw and a tunneling magneto-resistor on the handle’s joint to measure the grasping force and the jaws’ opening angle, respectively. The sensors’ data are analyzed using a microcontroller, and the output is displayed on a small screen and saved to a log file. This integrated system was evaluated by running multiple grasp-release tests using both elastomeric and biological tissue samples, in which the average force-to-angle-change ratio precisely resembled the stiffness of grasped samples. Another feature is the detection of hidden lumps by palpation, looking for sudden variations in the measured stiffness. In experiments, the real-time grasping feedback helped enhance the surgeons’ sorting accuracy of testing models based on their stiffness. The developed tool demonstrated a great potential for low-cost tactile sensing in MIS procedures, with room for future improvements. Significance: The proposed method can contribute to MIS by assessing stiffness, detecting hidden lumps, preventing excessive forces during operation, and reducing the learning curve for trainees.
format Online
Article
Text
id pubmed-9216325
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-92163252022-06-29 Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps IEEE J Transl Eng Health Med Article Minimally invasive surgery (MIS) incorporates surgical instruments through small incisions to perform procedures. Despite the potential advantages of MIS, the lack of tactile sensation and haptic feedback due to the indirect contact between the surgeon’s hands and the tissues restricts sensing the strength of applied forces or obtaining information about the biomechanical properties of tissues under operation. Accordingly, there is a crucial need for intelligent systems to provide an artificial tactile sensation to MIS surgeons and trainees. This study evaluates the potential of our proposed real-time grasping forces and deformation angles feedback to assist surgeons in detecting tissues’ stiffness. A prototype was developed using a standard laparoscopic grasper integrated with a force-sensitive resistor on one grasping jaw and a tunneling magneto-resistor on the handle’s joint to measure the grasping force and the jaws’ opening angle, respectively. The sensors’ data are analyzed using a microcontroller, and the output is displayed on a small screen and saved to a log file. This integrated system was evaluated by running multiple grasp-release tests using both elastomeric and biological tissue samples, in which the average force-to-angle-change ratio precisely resembled the stiffness of grasped samples. Another feature is the detection of hidden lumps by palpation, looking for sudden variations in the measured stiffness. In experiments, the real-time grasping feedback helped enhance the surgeons’ sorting accuracy of testing models based on their stiffness. The developed tool demonstrated a great potential for low-cost tactile sensing in MIS procedures, with room for future improvements. Significance: The proposed method can contribute to MIS by assessing stiffness, detecting hidden lumps, preventing excessive forces during operation, and reducing the learning curve for trainees. IEEE 2022-06-08 /pmc/articles/PMC9216325/ /pubmed/35774413 http://dx.doi.org/10.1109/JTEHM.2022.3180937 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. For more information, see https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Article
Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps
title Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps
title_full Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps
title_fullStr Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps
title_full_unstemmed Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps
title_short Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps
title_sort stiffness assessment and lump detection in minimally invasive surgery using in-house developed smart laparoscopic forceps
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9216325/
https://www.ncbi.nlm.nih.gov/pubmed/35774413
http://dx.doi.org/10.1109/JTEHM.2022.3180937
work_keys_str_mv AT stiffnessassessmentandlumpdetectioninminimallyinvasivesurgeryusinginhousedevelopedsmartlaparoscopicforceps
AT stiffnessassessmentandlumpdetectioninminimallyinvasivesurgeryusinginhousedevelopedsmartlaparoscopicforceps
AT stiffnessassessmentandlumpdetectioninminimallyinvasivesurgeryusinginhousedevelopedsmartlaparoscopicforceps
AT stiffnessassessmentandlumpdetectioninminimallyinvasivesurgeryusinginhousedevelopedsmartlaparoscopicforceps
AT stiffnessassessmentandlumpdetectioninminimallyinvasivesurgeryusinginhousedevelopedsmartlaparoscopicforceps
AT stiffnessassessmentandlumpdetectioninminimallyinvasivesurgeryusinginhousedevelopedsmartlaparoscopicforceps
AT stiffnessassessmentandlumpdetectioninminimallyinvasivesurgeryusinginhousedevelopedsmartlaparoscopicforceps