BACKGROUND: Obtaining an ideal vault is crucial in the implantable collamer lens (ICL) surgery. Prediction of the vault value is difficult since it requires the integration of multiple factors. The purpose of this study was to investigate the association between the iris shape and vault value in eye...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Zhikun, Meng, Lihui, Zhao, Xinyu, Chen, Youxin, Luo, Yan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9218336/
https://www.ncbi.nlm.nih.gov/pubmed/35755051
http://dx.doi.org/10.3389/fmed.2022.906433
_version_ 1784731864246779904
author Yang, Zhikun
Meng, Lihui
Zhao, Xinyu
Chen, Youxin
Luo, Yan
author_facet Yang, Zhikun
Meng, Lihui
Zhao, Xinyu
Chen, Youxin
Luo, Yan
author_sort Yang, Zhikun
collection PubMed
description BACKGROUND: Obtaining an ideal vault is crucial in the implantable collamer lens (ICL) surgery. Prediction of the vault value is difficult since it requires the integration of multiple factors. The purpose of this study was to investigate the association between the iris shape and vault value in eyes with thick lens. METHODS: The study was conducted in Peking Union Medical College Hospital. Patients who received ICL V4c between 2017 and 2021 were screened. Eyes with thick lens (>4.0 mm) and abnormal iris shape (concave or convex) were included. The preoperative biometric parameters and postoperative vault value were compared between eyes with concave shape group and convex shape group. The relationship between various factors and vault was assessed by spearman rank analysis and multiple linear regression analysis. Representative cases our strategies to deal with the abnormal vault were demonstrated. RESULTS: Twenty eight eyes of 14 patients with thick lens and concave or convex shape iris were eventually included, with 14 eyes of 7 patients in group 1 (concave shape iris) and the other 14 eyes of 7 patients in group 2 (convex shape iris). The mean vault of group 1 was (0.16 ± 0.07) mm, which was significantly lower than (0.88 ± 0.13) mm in group 2. Multiple linear regression analysis showed iris shape (P < 0.001) was only the explanatory variables associated with the postoperative vault. In group1, 4 eyes showed extremely large ACA, requiring a secondary surgical intervention. So all of them underwent ICL exchange for a larger ICL. In group2, the ICL was implanted in a vertical or oblique position to avoid or rescue an extremely large vault. CONCLUSION: Concave shape iris had a higher risk of low vault and convex shape iris were more likely to demonstrate high vault in eyes with thick lens. Exchanging ICL for the larger size and adjusting ICL to the vertical or oblique orientation are good option to rescue the low or high vault, respectively.
format Online
Article
Text
id pubmed-9218336
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-92183362022-06-24 Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology Yang, Zhikun Meng, Lihui Zhao, Xinyu Chen, Youxin Luo, Yan Front Med (Lausanne) Medicine BACKGROUND: Obtaining an ideal vault is crucial in the implantable collamer lens (ICL) surgery. Prediction of the vault value is difficult since it requires the integration of multiple factors. The purpose of this study was to investigate the association between the iris shape and vault value in eyes with thick lens. METHODS: The study was conducted in Peking Union Medical College Hospital. Patients who received ICL V4c between 2017 and 2021 were screened. Eyes with thick lens (>4.0 mm) and abnormal iris shape (concave or convex) were included. The preoperative biometric parameters and postoperative vault value were compared between eyes with concave shape group and convex shape group. The relationship between various factors and vault was assessed by spearman rank analysis and multiple linear regression analysis. Representative cases our strategies to deal with the abnormal vault were demonstrated. RESULTS: Twenty eight eyes of 14 patients with thick lens and concave or convex shape iris were eventually included, with 14 eyes of 7 patients in group 1 (concave shape iris) and the other 14 eyes of 7 patients in group 2 (convex shape iris). The mean vault of group 1 was (0.16 ± 0.07) mm, which was significantly lower than (0.88 ± 0.13) mm in group 2. Multiple linear regression analysis showed iris shape (P < 0.001) was only the explanatory variables associated with the postoperative vault. In group1, 4 eyes showed extremely large ACA, requiring a secondary surgical intervention. So all of them underwent ICL exchange for a larger ICL. In group2, the ICL was implanted in a vertical or oblique position to avoid or rescue an extremely large vault. CONCLUSION: Concave shape iris had a higher risk of low vault and convex shape iris were more likely to demonstrate high vault in eyes with thick lens. Exchanging ICL for the larger size and adjusting ICL to the vertical or oblique orientation are good option to rescue the low or high vault, respectively. Frontiers Media S.A. 2022-06-09 /pmc/articles/PMC9218336/ /pubmed/35755051 http://dx.doi.org/10.3389/fmed.2022.906433 Text en Copyright © 2022 Yang, Meng, Zhao, Chen and Luo. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Yang, Zhikun
Meng, Lihui
Zhao, Xinyu
Chen, Youxin
Luo, Yan
Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology
title Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology
title_full Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology
title_fullStr Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology
title_full_unstemmed Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology
title_short Clinical Prediction of Inadequate Vault in Eyes With Thick Lens After Implantable Collamer Lens Implantation Using Iris Morphology
title_sort clinical prediction of inadequate vault in eyes with thick lens after implantable collamer lens implantation using iris morphology
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9218336/
https://www.ncbi.nlm.nih.gov/pubmed/35755051
http://dx.doi.org/10.3389/fmed.2022.906433
work_keys_str_mv AT yangzhikun clinicalpredictionofinadequatevaultineyeswiththicklensafterimplantablecollamerlensimplantationusingirismorphology
AT menglihui clinicalpredictionofinadequatevaultineyeswiththicklensafterimplantablecollamerlensimplantationusingirismorphology
AT zhaoxinyu clinicalpredictionofinadequatevaultineyeswiththicklensafterimplantablecollamerlensimplantationusingirismorphology
AT chenyouxin clinicalpredictionofinadequatevaultineyeswiththicklensafterimplantablecollamerlensimplantationusingirismorphology
AT luoyan clinicalpredictionofinadequatevaultineyeswiththicklensafterimplantablecollamerlensimplantationusingirismorphology