Cargando…
Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability
Beat-by-beat variability (BBV) rhythms are observed in both cardiovascular (CV) and intracranial (IC) compartments, yet interactions between the two are not fully understood. Real-Time Phase-Contrast (RT-PC) MRI sequence was acquired for 30 healthy volunteers at 1st cervical level on a 3T scanner. T...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221193/ https://www.ncbi.nlm.nih.gov/pubmed/35735564 http://dx.doi.org/10.3390/bios12060417 |
_version_ | 1784732560387997696 |
---|---|
author | Baselli, Giuseppe Fasani, Federica Pelizzari, Laura Cazzoli, Marta Baglio, Francesca Laganà, Maria Marcella |
author_facet | Baselli, Giuseppe Fasani, Federica Pelizzari, Laura Cazzoli, Marta Baglio, Francesca Laganà, Maria Marcella |
author_sort | Baselli, Giuseppe |
collection | PubMed |
description | Beat-by-beat variability (BBV) rhythms are observed in both cardiovascular (CV) and intracranial (IC) compartments, yet interactions between the two are not fully understood. Real-Time Phase-Contrast (RT-PC) MRI sequence was acquired for 30 healthy volunteers at 1st cervical level on a 3T scanner. The arterial (AF), venous (VF), and cerebrospinal fluid (CSF) flow (CSFF) were computed as velocity integrals over the internal carotid artery, internal jugular vein, and CSF. AF, VF, and CSFF signals were segmented in inspiration and expiration beats, to assess the respiration influence. Systolic and diastolic BBV, and heart period series underwent autoregressive power spectral density analysis, to evaluate the low-frequency (LF, Mayer waves) and high frequency (HF, respiratory waves) components. The diastolic VF had the largest BBV. LF power was high in the diastolic AF series, poor in all CSFF series. The pulse wave analyses revealed higher mean amplitude during inspiration. Findings suggests a possible role of LF modulation of IC resistances and propagation of HF waves from VF to AF and CCSF. PC-RT-MRI could provide new insight into the interaction between CV and IC regulation and pave the way for a detailed analysis of the cerebrovascular effects of varied respiration patterns due to exercise and rehabilitation. |
format | Online Article Text |
id | pubmed-9221193 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92211932022-06-24 Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability Baselli, Giuseppe Fasani, Federica Pelizzari, Laura Cazzoli, Marta Baglio, Francesca Laganà, Maria Marcella Biosensors (Basel) Article Beat-by-beat variability (BBV) rhythms are observed in both cardiovascular (CV) and intracranial (IC) compartments, yet interactions between the two are not fully understood. Real-Time Phase-Contrast (RT-PC) MRI sequence was acquired for 30 healthy volunteers at 1st cervical level on a 3T scanner. The arterial (AF), venous (VF), and cerebrospinal fluid (CSF) flow (CSFF) were computed as velocity integrals over the internal carotid artery, internal jugular vein, and CSF. AF, VF, and CSFF signals were segmented in inspiration and expiration beats, to assess the respiration influence. Systolic and diastolic BBV, and heart period series underwent autoregressive power spectral density analysis, to evaluate the low-frequency (LF, Mayer waves) and high frequency (HF, respiratory waves) components. The diastolic VF had the largest BBV. LF power was high in the diastolic AF series, poor in all CSFF series. The pulse wave analyses revealed higher mean amplitude during inspiration. Findings suggests a possible role of LF modulation of IC resistances and propagation of HF waves from VF to AF and CCSF. PC-RT-MRI could provide new insight into the interaction between CV and IC regulation and pave the way for a detailed analysis of the cerebrovascular effects of varied respiration patterns due to exercise and rehabilitation. MDPI 2022-06-15 /pmc/articles/PMC9221193/ /pubmed/35735564 http://dx.doi.org/10.3390/bios12060417 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Baselli, Giuseppe Fasani, Federica Pelizzari, Laura Cazzoli, Marta Baglio, Francesca Laganà, Maria Marcella Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability |
title | Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability |
title_full | Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability |
title_fullStr | Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability |
title_full_unstemmed | Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability |
title_short | Real-Time Phase-Contrast MRI to Monitor Cervical Blood and Cerebrospinal Fluid Flow Beat-by-Beat Variability |
title_sort | real-time phase-contrast mri to monitor cervical blood and cerebrospinal fluid flow beat-by-beat variability |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221193/ https://www.ncbi.nlm.nih.gov/pubmed/35735564 http://dx.doi.org/10.3390/bios12060417 |
work_keys_str_mv | AT baselligiuseppe realtimephasecontrastmritomonitorcervicalbloodandcerebrospinalfluidflowbeatbybeatvariability AT fasanifederica realtimephasecontrastmritomonitorcervicalbloodandcerebrospinalfluidflowbeatbybeatvariability AT pelizzarilaura realtimephasecontrastmritomonitorcervicalbloodandcerebrospinalfluidflowbeatbybeatvariability AT cazzolimarta realtimephasecontrastmritomonitorcervicalbloodandcerebrospinalfluidflowbeatbybeatvariability AT bagliofrancesca realtimephasecontrastmritomonitorcervicalbloodandcerebrospinalfluidflowbeatbybeatvariability AT laganamariamarcella realtimephasecontrastmritomonitorcervicalbloodandcerebrospinalfluidflowbeatbybeatvariability |