Cargando…

Influence of Beam Angle on Normal Tissue Complication Probability of Knowledge-Based Head and Neck Cancer Proton Planning

SIMPLE SUMMARY: Knowledge-based treatment planning (KBP) solutions can be used to assist in the planning process by automatically generating patient-specific optimization objectives. A KBP model is typically derived from treatment plans with a similar planning methodology, for example beam angles. A...

Descripción completa

Detalles Bibliográficos
Autores principales: Hytönen, Roni, Vanderstraeten, Reynald, Dahele, Max, Verbakel, Wilko F. A. R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221467/
https://www.ncbi.nlm.nih.gov/pubmed/35740515
http://dx.doi.org/10.3390/cancers14122849
_version_ 1784732630407708672
author Hytönen, Roni
Vanderstraeten, Reynald
Dahele, Max
Verbakel, Wilko F. A. R.
author_facet Hytönen, Roni
Vanderstraeten, Reynald
Dahele, Max
Verbakel, Wilko F. A. R.
author_sort Hytönen, Roni
collection PubMed
description SIMPLE SUMMARY: Knowledge-based treatment planning (KBP) solutions can be used to assist in the planning process by automatically generating patient-specific optimization objectives. A KBP model is typically derived from treatment plans with a similar planning methodology, for example beam angles. An end-user might deviate from this methodology for a variety of reasons. The effect of such deviations on KBP plan quality has not been widely explored. We therefore studied this using a human-interaction free proton planning solution to create comparative plans with the default angles used when building the model, and altered beam angle arrangements. Because normal tissue complication probability (NTCP) can be used to select patients for proton therapy, this was used as the primary outcome metric for plan quality. The results show that the beam angle and number of beams only had a small effect on the plan NTCP. This suggests that the model is robust to the various beam arrangements within the range described in this analysis, although a method that automatically further adapts the KBP planning objectives further decreased the NTCP by 1–3%. ABSTRACT: Knowledge-based planning solutions have brought significant improvements in treatment planning. However, the performance of a proton-specific knowledge-based planning model in creating knowledge-based plans (KBPs) with beam angles differing from those used to train the model remains unexplored. We used a previously validated RapidPlanPT model and scripting to create nine KBPs, one with default and eight with altered beam angles, for 10 recent oropharynx cancer patients. The altered-angle plans were compared against the default-angle ones in terms of grade 2 dysphagia and xerostomia normal tissue complication probability (NTCP), mean doses of several organs at risk, and dose homogeneity index (HI). As KBP could be suboptimal, a proof of principle automatic iterative optimizer (AIO) was added with the aim of reducing the plan NTCP. There were no statistically significant differences in NTCP or HI between default- and altered-angle KBPs, and the altered-angle plans showed a <1% reduction in NTCP. AIO was able to reduce the sum of grade 2 NTCPs in 66/90 cases with mean a reduction of 3.5 ± 1.8%. While the altered-angle plans saw greater benefit from AIO, both default- and altered-angle plans could be improved, indicating that the KBP model alone was not completely optimal to achieve the lowest NTCP. Overall, the data showed that the model was robust to the various beam arrangements within the range described in this analysis.
format Online
Article
Text
id pubmed-9221467
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92214672022-06-24 Influence of Beam Angle on Normal Tissue Complication Probability of Knowledge-Based Head and Neck Cancer Proton Planning Hytönen, Roni Vanderstraeten, Reynald Dahele, Max Verbakel, Wilko F. A. R. Cancers (Basel) Article SIMPLE SUMMARY: Knowledge-based treatment planning (KBP) solutions can be used to assist in the planning process by automatically generating patient-specific optimization objectives. A KBP model is typically derived from treatment plans with a similar planning methodology, for example beam angles. An end-user might deviate from this methodology for a variety of reasons. The effect of such deviations on KBP plan quality has not been widely explored. We therefore studied this using a human-interaction free proton planning solution to create comparative plans with the default angles used when building the model, and altered beam angle arrangements. Because normal tissue complication probability (NTCP) can be used to select patients for proton therapy, this was used as the primary outcome metric for plan quality. The results show that the beam angle and number of beams only had a small effect on the plan NTCP. This suggests that the model is robust to the various beam arrangements within the range described in this analysis, although a method that automatically further adapts the KBP planning objectives further decreased the NTCP by 1–3%. ABSTRACT: Knowledge-based planning solutions have brought significant improvements in treatment planning. However, the performance of a proton-specific knowledge-based planning model in creating knowledge-based plans (KBPs) with beam angles differing from those used to train the model remains unexplored. We used a previously validated RapidPlanPT model and scripting to create nine KBPs, one with default and eight with altered beam angles, for 10 recent oropharynx cancer patients. The altered-angle plans were compared against the default-angle ones in terms of grade 2 dysphagia and xerostomia normal tissue complication probability (NTCP), mean doses of several organs at risk, and dose homogeneity index (HI). As KBP could be suboptimal, a proof of principle automatic iterative optimizer (AIO) was added with the aim of reducing the plan NTCP. There were no statistically significant differences in NTCP or HI between default- and altered-angle KBPs, and the altered-angle plans showed a <1% reduction in NTCP. AIO was able to reduce the sum of grade 2 NTCPs in 66/90 cases with mean a reduction of 3.5 ± 1.8%. While the altered-angle plans saw greater benefit from AIO, both default- and altered-angle plans could be improved, indicating that the KBP model alone was not completely optimal to achieve the lowest NTCP. Overall, the data showed that the model was robust to the various beam arrangements within the range described in this analysis. MDPI 2022-06-09 /pmc/articles/PMC9221467/ /pubmed/35740515 http://dx.doi.org/10.3390/cancers14122849 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hytönen, Roni
Vanderstraeten, Reynald
Dahele, Max
Verbakel, Wilko F. A. R.
Influence of Beam Angle on Normal Tissue Complication Probability of Knowledge-Based Head and Neck Cancer Proton Planning
title Influence of Beam Angle on Normal Tissue Complication Probability of Knowledge-Based Head and Neck Cancer Proton Planning
title_full Influence of Beam Angle on Normal Tissue Complication Probability of Knowledge-Based Head and Neck Cancer Proton Planning
title_fullStr Influence of Beam Angle on Normal Tissue Complication Probability of Knowledge-Based Head and Neck Cancer Proton Planning
title_full_unstemmed Influence of Beam Angle on Normal Tissue Complication Probability of Knowledge-Based Head and Neck Cancer Proton Planning
title_short Influence of Beam Angle on Normal Tissue Complication Probability of Knowledge-Based Head and Neck Cancer Proton Planning
title_sort influence of beam angle on normal tissue complication probability of knowledge-based head and neck cancer proton planning
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221467/
https://www.ncbi.nlm.nih.gov/pubmed/35740515
http://dx.doi.org/10.3390/cancers14122849
work_keys_str_mv AT hytonenroni influenceofbeamangleonnormaltissuecomplicationprobabilityofknowledgebasedheadandneckcancerprotonplanning
AT vanderstraetenreynald influenceofbeamangleonnormaltissuecomplicationprobabilityofknowledgebasedheadandneckcancerprotonplanning
AT dahelemax influenceofbeamangleonnormaltissuecomplicationprobabilityofknowledgebasedheadandneckcancerprotonplanning
AT verbakelwilkofar influenceofbeamangleonnormaltissuecomplicationprobabilityofknowledgebasedheadandneckcancerprotonplanning