Cargando…
Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization
The traveled distance and orientation of capsule endoscopes for each video frame are not available in commercial systems, but they would be highly relevant for physicians. Furthermore, scientific approaches lack precisely tracking the capsules along curved trajectories within the typical gastrointes...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221653/ https://www.ncbi.nlm.nih.gov/pubmed/35741143 http://dx.doi.org/10.3390/diagnostics12061333 |
_version_ | 1784732675170369536 |
---|---|
author | Zeising, Samuel Chen, Lu Thalmayer, Angelika Lübke, Maximilian Fischer, Georg Kirchner, Jens |
author_facet | Zeising, Samuel Chen, Lu Thalmayer, Angelika Lübke, Maximilian Fischer, Georg Kirchner, Jens |
author_sort | Zeising, Samuel |
collection | PubMed |
description | The traveled distance and orientation of capsule endoscopes for each video frame are not available in commercial systems, but they would be highly relevant for physicians. Furthermore, scientific approaches lack precisely tracking the capsules along curved trajectories within the typical gastrointestinal tract. Recently, we showed that the differential static magnetic localisation method is suitable for the precise absolute localisation of permanent magnets assumed to be integrated into capsule endoscopes. Thus, in the present study, the differential method was employed to track permanent magnets in terms of traveled distance and orientation along a length trajectory of 487.5 mm, representing a model of the winding gastrointestinal tract. Permanent magnets with a diameter of 10 mm and different lengths were used to find a lower boundary for magnet size. Results reveal that the mean relative distance and orientation errors did not exceed 4.3 ± 3.3%, and 2 ± 0.6 [Formula: see text] , respectively, when the magnet length was at least 5 mm. Thus, a 5 mm long magnet would be a good compromise between achievable tracking accuracy and magnet volume, which are essential for integration into small commercial capsules. Overall, the proposed tracking accuracy was better than that of the state of the art within a region covering the typical gastrointestinal-tract size. |
format | Online Article Text |
id | pubmed-9221653 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92216532022-06-24 Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization Zeising, Samuel Chen, Lu Thalmayer, Angelika Lübke, Maximilian Fischer, Georg Kirchner, Jens Diagnostics (Basel) Communication The traveled distance and orientation of capsule endoscopes for each video frame are not available in commercial systems, but they would be highly relevant for physicians. Furthermore, scientific approaches lack precisely tracking the capsules along curved trajectories within the typical gastrointestinal tract. Recently, we showed that the differential static magnetic localisation method is suitable for the precise absolute localisation of permanent magnets assumed to be integrated into capsule endoscopes. Thus, in the present study, the differential method was employed to track permanent magnets in terms of traveled distance and orientation along a length trajectory of 487.5 mm, representing a model of the winding gastrointestinal tract. Permanent magnets with a diameter of 10 mm and different lengths were used to find a lower boundary for magnet size. Results reveal that the mean relative distance and orientation errors did not exceed 4.3 ± 3.3%, and 2 ± 0.6 [Formula: see text] , respectively, when the magnet length was at least 5 mm. Thus, a 5 mm long magnet would be a good compromise between achievable tracking accuracy and magnet volume, which are essential for integration into small commercial capsules. Overall, the proposed tracking accuracy was better than that of the state of the art within a region covering the typical gastrointestinal-tract size. MDPI 2022-05-27 /pmc/articles/PMC9221653/ /pubmed/35741143 http://dx.doi.org/10.3390/diagnostics12061333 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Zeising, Samuel Chen, Lu Thalmayer, Angelika Lübke, Maximilian Fischer, Georg Kirchner, Jens Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization |
title | Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization |
title_full | Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization |
title_fullStr | Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization |
title_full_unstemmed | Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization |
title_short | Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization |
title_sort | tracking the traveled distance of capsule endoscopes along a gastrointestinal-tract model using differential static magnetic localization |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221653/ https://www.ncbi.nlm.nih.gov/pubmed/35741143 http://dx.doi.org/10.3390/diagnostics12061333 |
work_keys_str_mv | AT zeisingsamuel trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization AT chenlu trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization AT thalmayerangelika trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization AT lubkemaximilian trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization AT fischergeorg trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization AT kirchnerjens trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization |