Cargando…

Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization

The traveled distance and orientation of capsule endoscopes for each video frame are not available in commercial systems, but they would be highly relevant for physicians. Furthermore, scientific approaches lack precisely tracking the capsules along curved trajectories within the typical gastrointes...

Descripción completa

Detalles Bibliográficos
Autores principales: Zeising, Samuel, Chen, Lu, Thalmayer, Angelika, Lübke, Maximilian, Fischer, Georg, Kirchner, Jens
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221653/
https://www.ncbi.nlm.nih.gov/pubmed/35741143
http://dx.doi.org/10.3390/diagnostics12061333
_version_ 1784732675170369536
author Zeising, Samuel
Chen, Lu
Thalmayer, Angelika
Lübke, Maximilian
Fischer, Georg
Kirchner, Jens
author_facet Zeising, Samuel
Chen, Lu
Thalmayer, Angelika
Lübke, Maximilian
Fischer, Georg
Kirchner, Jens
author_sort Zeising, Samuel
collection PubMed
description The traveled distance and orientation of capsule endoscopes for each video frame are not available in commercial systems, but they would be highly relevant for physicians. Furthermore, scientific approaches lack precisely tracking the capsules along curved trajectories within the typical gastrointestinal tract. Recently, we showed that the differential static magnetic localisation method is suitable for the precise absolute localisation of permanent magnets assumed to be integrated into capsule endoscopes. Thus, in the present study, the differential method was employed to track permanent magnets in terms of traveled distance and orientation along a length trajectory of 487.5 mm, representing a model of the winding gastrointestinal tract. Permanent magnets with a diameter of 10 mm and different lengths were used to find a lower boundary for magnet size. Results reveal that the mean relative distance and orientation errors did not exceed 4.3 ± 3.3%, and 2 ± 0.6 [Formula: see text] , respectively, when the magnet length was at least 5 mm. Thus, a 5 mm long magnet would be a good compromise between achievable tracking accuracy and magnet volume, which are essential for integration into small commercial capsules. Overall, the proposed tracking accuracy was better than that of the state of the art within a region covering the typical gastrointestinal-tract size.
format Online
Article
Text
id pubmed-9221653
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92216532022-06-24 Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization Zeising, Samuel Chen, Lu Thalmayer, Angelika Lübke, Maximilian Fischer, Georg Kirchner, Jens Diagnostics (Basel) Communication The traveled distance and orientation of capsule endoscopes for each video frame are not available in commercial systems, but they would be highly relevant for physicians. Furthermore, scientific approaches lack precisely tracking the capsules along curved trajectories within the typical gastrointestinal tract. Recently, we showed that the differential static magnetic localisation method is suitable for the precise absolute localisation of permanent magnets assumed to be integrated into capsule endoscopes. Thus, in the present study, the differential method was employed to track permanent magnets in terms of traveled distance and orientation along a length trajectory of 487.5 mm, representing a model of the winding gastrointestinal tract. Permanent magnets with a diameter of 10 mm and different lengths were used to find a lower boundary for magnet size. Results reveal that the mean relative distance and orientation errors did not exceed 4.3 ± 3.3%, and 2 ± 0.6 [Formula: see text] , respectively, when the magnet length was at least 5 mm. Thus, a 5 mm long magnet would be a good compromise between achievable tracking accuracy and magnet volume, which are essential for integration into small commercial capsules. Overall, the proposed tracking accuracy was better than that of the state of the art within a region covering the typical gastrointestinal-tract size. MDPI 2022-05-27 /pmc/articles/PMC9221653/ /pubmed/35741143 http://dx.doi.org/10.3390/diagnostics12061333 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Zeising, Samuel
Chen, Lu
Thalmayer, Angelika
Lübke, Maximilian
Fischer, Georg
Kirchner, Jens
Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization
title Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization
title_full Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization
title_fullStr Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization
title_full_unstemmed Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization
title_short Tracking the Traveled Distance of Capsule Endoscopes along a Gastrointestinal-Tract Model Using Differential Static Magnetic Localization
title_sort tracking the traveled distance of capsule endoscopes along a gastrointestinal-tract model using differential static magnetic localization
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221653/
https://www.ncbi.nlm.nih.gov/pubmed/35741143
http://dx.doi.org/10.3390/diagnostics12061333
work_keys_str_mv AT zeisingsamuel trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization
AT chenlu trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization
AT thalmayerangelika trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization
AT lubkemaximilian trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization
AT fischergeorg trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization
AT kirchnerjens trackingthetraveleddistanceofcapsuleendoscopesalongagastrointestinaltractmodelusingdifferentialstaticmagneticlocalization