Cargando…

Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii

Performances of the colistin antimicrobial susceptibility testing (AST) systems of Acinetobacter baumannii vary depending on the manufacturer, and data on colistin-resistant A. baumannii are limited. We evaluated the VITEK2 and Sensititre systems to determine colistin resistance and minimum inhibito...

Descripción completa

Detalles Bibliográficos
Autores principales: Chung, Hae-Sun, Kim, Soo-Kyung, Hahm, Chorong, Lee, Miae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221671/
https://www.ncbi.nlm.nih.gov/pubmed/35741297
http://dx.doi.org/10.3390/diagnostics12061487
_version_ 1784732679583825920
author Chung, Hae-Sun
Kim, Soo-Kyung
Hahm, Chorong
Lee, Miae
author_facet Chung, Hae-Sun
Kim, Soo-Kyung
Hahm, Chorong
Lee, Miae
author_sort Chung, Hae-Sun
collection PubMed
description Performances of the colistin antimicrobial susceptibility testing (AST) systems of Acinetobacter baumannii vary depending on the manufacturer, and data on colistin-resistant A. baumannii are limited. We evaluated the VITEK2 and Sensititre systems to determine colistin resistance and minimum inhibitory concentration (MIC) for A. baumannii isolated from a clinical microbiology laboratory. A total of 213 clinical A. baumannii isolates were tested, including 81 colistin-resistant A. baumannii. ASTs were performed using the VITEK2 and Sensititre systems according to the manufacturer’s instructions. Reference MICs for colistin were determined using the manual broth microdilution method (BMD). The results of the two AST methods were compared with the BMD results. VITEK2 and Sensititre systems showed category agreements of 95.3% and 99.1%, respectively. VITEK2 had a relatively high very major error (VME) rate (9.9%). Sensititre reported higher MICs than the reference method for the susceptible isolates and showed low essential agreement. In conclusion, the automated systems investigated in this study showed good category agreements for colistin AST of A. baumannii. However, VITEK2 had a high VME rate, and Sensititre had differences in MIC results. Colistin AST remains a challenging task in the clinical laboratory.
format Online
Article
Text
id pubmed-9221671
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92216712022-06-24 Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii Chung, Hae-Sun Kim, Soo-Kyung Hahm, Chorong Lee, Miae Diagnostics (Basel) Article Performances of the colistin antimicrobial susceptibility testing (AST) systems of Acinetobacter baumannii vary depending on the manufacturer, and data on colistin-resistant A. baumannii are limited. We evaluated the VITEK2 and Sensititre systems to determine colistin resistance and minimum inhibitory concentration (MIC) for A. baumannii isolated from a clinical microbiology laboratory. A total of 213 clinical A. baumannii isolates were tested, including 81 colistin-resistant A. baumannii. ASTs were performed using the VITEK2 and Sensititre systems according to the manufacturer’s instructions. Reference MICs for colistin were determined using the manual broth microdilution method (BMD). The results of the two AST methods were compared with the BMD results. VITEK2 and Sensititre systems showed category agreements of 95.3% and 99.1%, respectively. VITEK2 had a relatively high very major error (VME) rate (9.9%). Sensititre reported higher MICs than the reference method for the susceptible isolates and showed low essential agreement. In conclusion, the automated systems investigated in this study showed good category agreements for colistin AST of A. baumannii. However, VITEK2 had a high VME rate, and Sensititre had differences in MIC results. Colistin AST remains a challenging task in the clinical laboratory. MDPI 2022-06-17 /pmc/articles/PMC9221671/ /pubmed/35741297 http://dx.doi.org/10.3390/diagnostics12061487 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chung, Hae-Sun
Kim, Soo-Kyung
Hahm, Chorong
Lee, Miae
Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii
title Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii
title_full Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii
title_fullStr Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii
title_full_unstemmed Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii
title_short Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii
title_sort performance evaluation of the vitek2 and sensititre systems to determine colistin resistance and mic for acinetobacter baumannii
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221671/
https://www.ncbi.nlm.nih.gov/pubmed/35741297
http://dx.doi.org/10.3390/diagnostics12061487
work_keys_str_mv AT chunghaesun performanceevaluationofthevitek2andsensititresystemstodeterminecolistinresistanceandmicforacinetobacterbaumannii
AT kimsookyung performanceevaluationofthevitek2andsensititresystemstodeterminecolistinresistanceandmicforacinetobacterbaumannii
AT hahmchorong performanceevaluationofthevitek2andsensititresystemstodeterminecolistinresistanceandmicforacinetobacterbaumannii
AT leemiae performanceevaluationofthevitek2andsensititresystemstodeterminecolistinresistanceandmicforacinetobacterbaumannii