Cargando…
Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii
Performances of the colistin antimicrobial susceptibility testing (AST) systems of Acinetobacter baumannii vary depending on the manufacturer, and data on colistin-resistant A. baumannii are limited. We evaluated the VITEK2 and Sensititre systems to determine colistin resistance and minimum inhibito...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221671/ https://www.ncbi.nlm.nih.gov/pubmed/35741297 http://dx.doi.org/10.3390/diagnostics12061487 |
_version_ | 1784732679583825920 |
---|---|
author | Chung, Hae-Sun Kim, Soo-Kyung Hahm, Chorong Lee, Miae |
author_facet | Chung, Hae-Sun Kim, Soo-Kyung Hahm, Chorong Lee, Miae |
author_sort | Chung, Hae-Sun |
collection | PubMed |
description | Performances of the colistin antimicrobial susceptibility testing (AST) systems of Acinetobacter baumannii vary depending on the manufacturer, and data on colistin-resistant A. baumannii are limited. We evaluated the VITEK2 and Sensititre systems to determine colistin resistance and minimum inhibitory concentration (MIC) for A. baumannii isolated from a clinical microbiology laboratory. A total of 213 clinical A. baumannii isolates were tested, including 81 colistin-resistant A. baumannii. ASTs were performed using the VITEK2 and Sensititre systems according to the manufacturer’s instructions. Reference MICs for colistin were determined using the manual broth microdilution method (BMD). The results of the two AST methods were compared with the BMD results. VITEK2 and Sensititre systems showed category agreements of 95.3% and 99.1%, respectively. VITEK2 had a relatively high very major error (VME) rate (9.9%). Sensititre reported higher MICs than the reference method for the susceptible isolates and showed low essential agreement. In conclusion, the automated systems investigated in this study showed good category agreements for colistin AST of A. baumannii. However, VITEK2 had a high VME rate, and Sensititre had differences in MIC results. Colistin AST remains a challenging task in the clinical laboratory. |
format | Online Article Text |
id | pubmed-9221671 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92216712022-06-24 Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii Chung, Hae-Sun Kim, Soo-Kyung Hahm, Chorong Lee, Miae Diagnostics (Basel) Article Performances of the colistin antimicrobial susceptibility testing (AST) systems of Acinetobacter baumannii vary depending on the manufacturer, and data on colistin-resistant A. baumannii are limited. We evaluated the VITEK2 and Sensititre systems to determine colistin resistance and minimum inhibitory concentration (MIC) for A. baumannii isolated from a clinical microbiology laboratory. A total of 213 clinical A. baumannii isolates were tested, including 81 colistin-resistant A. baumannii. ASTs were performed using the VITEK2 and Sensititre systems according to the manufacturer’s instructions. Reference MICs for colistin were determined using the manual broth microdilution method (BMD). The results of the two AST methods were compared with the BMD results. VITEK2 and Sensititre systems showed category agreements of 95.3% and 99.1%, respectively. VITEK2 had a relatively high very major error (VME) rate (9.9%). Sensititre reported higher MICs than the reference method for the susceptible isolates and showed low essential agreement. In conclusion, the automated systems investigated in this study showed good category agreements for colistin AST of A. baumannii. However, VITEK2 had a high VME rate, and Sensititre had differences in MIC results. Colistin AST remains a challenging task in the clinical laboratory. MDPI 2022-06-17 /pmc/articles/PMC9221671/ /pubmed/35741297 http://dx.doi.org/10.3390/diagnostics12061487 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chung, Hae-Sun Kim, Soo-Kyung Hahm, Chorong Lee, Miae Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii |
title | Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii |
title_full | Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii |
title_fullStr | Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii |
title_full_unstemmed | Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii |
title_short | Performance Evaluation of the VITEK2 and Sensititre Systems to Determine Colistin Resistance and MIC for Acinetobacter baumannii |
title_sort | performance evaluation of the vitek2 and sensititre systems to determine colistin resistance and mic for acinetobacter baumannii |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221671/ https://www.ncbi.nlm.nih.gov/pubmed/35741297 http://dx.doi.org/10.3390/diagnostics12061487 |
work_keys_str_mv | AT chunghaesun performanceevaluationofthevitek2andsensititresystemstodeterminecolistinresistanceandmicforacinetobacterbaumannii AT kimsookyung performanceevaluationofthevitek2andsensititresystemstodeterminecolistinresistanceandmicforacinetobacterbaumannii AT hahmchorong performanceevaluationofthevitek2andsensititresystemstodeterminecolistinresistanceandmicforacinetobacterbaumannii AT leemiae performanceevaluationofthevitek2andsensititresystemstodeterminecolistinresistanceandmicforacinetobacterbaumannii |