Cargando…

Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT

Background: The purpose of the study was to investigate the accuracy of mini-implant placement with the use of a computer designed surgical guide derived by intraoral scanning alongside Cone-Beam Computed Tomography (CBCT) or the use of a 2D radiograph. Methods: Thirty-five mini-implants (Aarhus(®)...

Descripción completa

Detalles Bibliográficos
Autores principales: Vasoglou, Georgios, Stefanidaki, Ioanna, Apostolopoulos, Konstantinos, Fotakidou, Evmorfia, Vasoglou, Michail
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221763/
https://www.ncbi.nlm.nih.gov/pubmed/35735647
http://dx.doi.org/10.3390/dj10060104
_version_ 1784732702729043968
author Vasoglou, Georgios
Stefanidaki, Ioanna
Apostolopoulos, Konstantinos
Fotakidou, Evmorfia
Vasoglou, Michail
author_facet Vasoglou, Georgios
Stefanidaki, Ioanna
Apostolopoulos, Konstantinos
Fotakidou, Evmorfia
Vasoglou, Michail
author_sort Vasoglou, Georgios
collection PubMed
description Background: The purpose of the study was to investigate the accuracy of mini-implant placement with the use of a computer designed surgical guide derived by intraoral scanning alongside Cone-Beam Computed Tomography (CBCT) or the use of a 2D radiograph. Methods: Thirty-five mini-implants (Aarhus(®) System: n = 20, Ø: 1.5 mm and AbsoAnchor(®): n = 15, Ø: 1.3–1.4 mm) were placed in the maxilla and mandible of 15 orthodontic patients for anchorage purposes in cases where a CBCT was needed due to impacted teeth or for safety reasons. All were placed with the help of a computer designed surgical guide. One implant became loose and was excluded from the study. For 18 mini-implants (study group), CBCT and intraoral scanning were used for guide design, while for 16 (control group) only intraoral scanning and panoramic imaging information were used. Mini-implant position was recorded by angular and linear measurements on digital models created by combining Digital Imaging and Communications in Medicine (DICOM) and stereolithography (.stl) files. Accuracy in positioning was determined by comparing corresponding measurements for virtual and real positioned mini-implants on digital models before and after operation. The results were statistically analyzed with t-tests and the Mann-Whitney test. Results: No significant statistical differences were found for pre- and post-operational angular measurements in the study group, while significant statistical differences occurred on the same measurements for the control group (coronal angle 13.6° pre-op and 22.7° post-op, p-value = 0.002, axial angle 13.4° pre-op and 15.9° post-op, p-value = 0.034). Linear measurements pre- and post-operational for either group presented no significant statistical differences. Conclusions: A 3D designed and manufactured surgical guide with information concerning CBCT and intraoral scanning ensures accuracy on mini-implant placement while design of the guide without the use of a CBCT is less accurate, especially on inclination of the implant.
format Online
Article
Text
id pubmed-9221763
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92217632022-06-24 Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT Vasoglou, Georgios Stefanidaki, Ioanna Apostolopoulos, Konstantinos Fotakidou, Evmorfia Vasoglou, Michail Dent J (Basel) Article Background: The purpose of the study was to investigate the accuracy of mini-implant placement with the use of a computer designed surgical guide derived by intraoral scanning alongside Cone-Beam Computed Tomography (CBCT) or the use of a 2D radiograph. Methods: Thirty-five mini-implants (Aarhus(®) System: n = 20, Ø: 1.5 mm and AbsoAnchor(®): n = 15, Ø: 1.3–1.4 mm) were placed in the maxilla and mandible of 15 orthodontic patients for anchorage purposes in cases where a CBCT was needed due to impacted teeth or for safety reasons. All were placed with the help of a computer designed surgical guide. One implant became loose and was excluded from the study. For 18 mini-implants (study group), CBCT and intraoral scanning were used for guide design, while for 16 (control group) only intraoral scanning and panoramic imaging information were used. Mini-implant position was recorded by angular and linear measurements on digital models created by combining Digital Imaging and Communications in Medicine (DICOM) and stereolithography (.stl) files. Accuracy in positioning was determined by comparing corresponding measurements for virtual and real positioned mini-implants on digital models before and after operation. The results were statistically analyzed with t-tests and the Mann-Whitney test. Results: No significant statistical differences were found for pre- and post-operational angular measurements in the study group, while significant statistical differences occurred on the same measurements for the control group (coronal angle 13.6° pre-op and 22.7° post-op, p-value = 0.002, axial angle 13.4° pre-op and 15.9° post-op, p-value = 0.034). Linear measurements pre- and post-operational for either group presented no significant statistical differences. Conclusions: A 3D designed and manufactured surgical guide with information concerning CBCT and intraoral scanning ensures accuracy on mini-implant placement while design of the guide without the use of a CBCT is less accurate, especially on inclination of the implant. MDPI 2022-06-08 /pmc/articles/PMC9221763/ /pubmed/35735647 http://dx.doi.org/10.3390/dj10060104 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Vasoglou, Georgios
Stefanidaki, Ioanna
Apostolopoulos, Konstantinos
Fotakidou, Evmorfia
Vasoglou, Michail
Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT
title Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT
title_full Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT
title_fullStr Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT
title_full_unstemmed Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT
title_short Accuracy of Mini-Implant Placement Using a Computer-Aided Designed Surgical Guide, with Information of Intraoral Scan and the Use of a Cone-Beam CT
title_sort accuracy of mini-implant placement using a computer-aided designed surgical guide, with information of intraoral scan and the use of a cone-beam ct
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221763/
https://www.ncbi.nlm.nih.gov/pubmed/35735647
http://dx.doi.org/10.3390/dj10060104
work_keys_str_mv AT vasoglougeorgios accuracyofminiimplantplacementusingacomputeraideddesignedsurgicalguidewithinformationofintraoralscanandtheuseofaconebeamct
AT stefanidakiioanna accuracyofminiimplantplacementusingacomputeraideddesignedsurgicalguidewithinformationofintraoralscanandtheuseofaconebeamct
AT apostolopouloskonstantinos accuracyofminiimplantplacementusingacomputeraideddesignedsurgicalguidewithinformationofintraoralscanandtheuseofaconebeamct
AT fotakidouevmorfia accuracyofminiimplantplacementusingacomputeraideddesignedsurgicalguidewithinformationofintraoralscanandtheuseofaconebeamct
AT vasogloumichail accuracyofminiimplantplacementusingacomputeraideddesignedsurgicalguidewithinformationofintraoralscanandtheuseofaconebeamct