Cargando…

Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography

Atrial fibrillation (AFib) is a common type of arrhythmia that is often clinically asymptomatic, which increases the risk of stroke significantly but can be prevented with anticoagulation. The photoplethysmogram (PPG) has recently attracted a lot of attention as a surrogate for electrocardiography (...

Descripción completa

Detalles Bibliográficos
Autores principales: Chu, Justin, Yang, Wen-Tse, Chang, Yao-Ting, Yang, Fu-Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221814/
https://www.ncbi.nlm.nih.gov/pubmed/35741114
http://dx.doi.org/10.3390/diagnostics12061304
_version_ 1784732715469242368
author Chu, Justin
Yang, Wen-Tse
Chang, Yao-Ting
Yang, Fu-Liang
author_facet Chu, Justin
Yang, Wen-Tse
Chang, Yao-Ting
Yang, Fu-Liang
author_sort Chu, Justin
collection PubMed
description Atrial fibrillation (AFib) is a common type of arrhythmia that is often clinically asymptomatic, which increases the risk of stroke significantly but can be prevented with anticoagulation. The photoplethysmogram (PPG) has recently attracted a lot of attention as a surrogate for electrocardiography (ECG) on atrial fibrillation (AFib) detection, with its out-of-hospital usability for rapid screening or long-term monitoring. Previous studies on AFib detection via PPG signals have achieved good results, but were short of intuitive criteria like ECG p-wave absence or not, especially while using interval randomness to detect AFib suffering from conjunction with premature contractions (PAC/PVC). In this study, we newly developed a PPG flux (pulse amplitude) and interval plots-based methodology, simply comprising an irregularity index threshold of 20 and regression error threshold of 0.06 for the precise automatic detection of AFib. The proposed method with automated detection on AFib shows a combined sensitivity, specificity, accuracy, and precision of 1, 0.995, 0.995, and 0.952 across the 460 samples. Furthermore, the flux-interval plot configuration also acts as a very intuitive tool for visual reassessment to confirm the automatic detection of AFib by its distinctive plot pattern compared to other cardiac rhythms. The study demonstrated that exclusive 2 false-positive cases could be corrected after the reassessment. With the methodology’s background theory well established, the detection process automated and visualized, and the PPG sensors already extensively used, this technology is very user-friendly and convincing for promoted to in-house AFib diagnostics.
format Online
Article
Text
id pubmed-9221814
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92218142022-06-24 Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography Chu, Justin Yang, Wen-Tse Chang, Yao-Ting Yang, Fu-Liang Diagnostics (Basel) Article Atrial fibrillation (AFib) is a common type of arrhythmia that is often clinically asymptomatic, which increases the risk of stroke significantly but can be prevented with anticoagulation. The photoplethysmogram (PPG) has recently attracted a lot of attention as a surrogate for electrocardiography (ECG) on atrial fibrillation (AFib) detection, with its out-of-hospital usability for rapid screening or long-term monitoring. Previous studies on AFib detection via PPG signals have achieved good results, but were short of intuitive criteria like ECG p-wave absence or not, especially while using interval randomness to detect AFib suffering from conjunction with premature contractions (PAC/PVC). In this study, we newly developed a PPG flux (pulse amplitude) and interval plots-based methodology, simply comprising an irregularity index threshold of 20 and regression error threshold of 0.06 for the precise automatic detection of AFib. The proposed method with automated detection on AFib shows a combined sensitivity, specificity, accuracy, and precision of 1, 0.995, 0.995, and 0.952 across the 460 samples. Furthermore, the flux-interval plot configuration also acts as a very intuitive tool for visual reassessment to confirm the automatic detection of AFib by its distinctive plot pattern compared to other cardiac rhythms. The study demonstrated that exclusive 2 false-positive cases could be corrected after the reassessment. With the methodology’s background theory well established, the detection process automated and visualized, and the PPG sensors already extensively used, this technology is very user-friendly and convincing for promoted to in-house AFib diagnostics. MDPI 2022-05-24 /pmc/articles/PMC9221814/ /pubmed/35741114 http://dx.doi.org/10.3390/diagnostics12061304 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chu, Justin
Yang, Wen-Tse
Chang, Yao-Ting
Yang, Fu-Liang
Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography
title Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography
title_full Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography
title_fullStr Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography
title_full_unstemmed Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography
title_short Visual Reassessment with Flux-Interval Plot Configuration after Automatic Classification for Accurate Atrial Fibrillation Detection by Photoplethysmography
title_sort visual reassessment with flux-interval plot configuration after automatic classification for accurate atrial fibrillation detection by photoplethysmography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221814/
https://www.ncbi.nlm.nih.gov/pubmed/35741114
http://dx.doi.org/10.3390/diagnostics12061304
work_keys_str_mv AT chujustin visualreassessmentwithfluxintervalplotconfigurationafterautomaticclassificationforaccurateatrialfibrillationdetectionbyphotoplethysmography
AT yangwentse visualreassessmentwithfluxintervalplotconfigurationafterautomaticclassificationforaccurateatrialfibrillationdetectionbyphotoplethysmography
AT changyaoting visualreassessmentwithfluxintervalplotconfigurationafterautomaticclassificationforaccurateatrialfibrillationdetectionbyphotoplethysmography
AT yangfuliang visualreassessmentwithfluxintervalplotconfigurationafterautomaticclassificationforaccurateatrialfibrillationdetectionbyphotoplethysmography