Cargando…

Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber

We aimed to compare measurements from three of the most widely used software packages in the literature and to generate conversion algorithms for measurement of the central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) between SIVA and IVAN and between SIVA and VAMPIRE....

Descripción completa

Detalles Bibliográficos
Autores principales: Mautuit, Thibaud, Cunnac, Pierre, Cheung, Carol Y., Wong, Tien Y., Hogg, Stephen, Trucco, Emanuele, Daien, Vincent, MacGillivray, Thomas J., Labarère, José, Chiquet, Christophe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221842/
https://www.ncbi.nlm.nih.gov/pubmed/35741127
http://dx.doi.org/10.3390/diagnostics12061317
_version_ 1784732723184664576
author Mautuit, Thibaud
Cunnac, Pierre
Cheung, Carol Y.
Wong, Tien Y.
Hogg, Stephen
Trucco, Emanuele
Daien, Vincent
MacGillivray, Thomas J.
Labarère, José
Chiquet, Christophe
author_facet Mautuit, Thibaud
Cunnac, Pierre
Cheung, Carol Y.
Wong, Tien Y.
Hogg, Stephen
Trucco, Emanuele
Daien, Vincent
MacGillivray, Thomas J.
Labarère, José
Chiquet, Christophe
author_sort Mautuit, Thibaud
collection PubMed
description We aimed to compare measurements from three of the most widely used software packages in the literature and to generate conversion algorithms for measurement of the central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) between SIVA and IVAN and between SIVA and VAMPIRE. We analyzed 223 retinal photographs from 133 human participants using both SIVA, VAMPIRE and IVAN independently for computing CRAE and CRVE. Agreement between measurements was assessed using Bland–Altman plots and intra-class correlation coefficients. A conversion algorithm between measurements was carried out using linear regression, and validated using bootstrapping and root-mean-square error. The agreement between VAMPIRE and IVAN was poor to moderate: The mean difference was 20.2 µm (95% limits of agreement, LOA, −12.2–52.6 µm) for CRAE and 21.0 µm (95% LOA, −17.5–59.5 µm) for CRVE. The agreement between VAMPIRE and SIVA was also poor to moderate: the mean difference was 36.6 µm (95% LOA, −12.8–60.4 µm) for CRAE, and 40.3 µm (95% LOA, 5.6–75.0 µm) for CRVE. The agreement between IVAN and SIVA was good to excellent: the mean difference was 16.4 µm (95% LOA, −4.25–37.0 µm) for CRAE, and 19.3 µm (95% LOA, 0.09–38.6 µm) for CRVE. We propose an algorithm converting IVAN and VAMPIRE measurements into SIVA-estimated measurements, which could be used to homogenize sets of vessel measurements obtained with different software packages.
format Online
Article
Text
id pubmed-9221842
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92218422022-06-24 Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber Mautuit, Thibaud Cunnac, Pierre Cheung, Carol Y. Wong, Tien Y. Hogg, Stephen Trucco, Emanuele Daien, Vincent MacGillivray, Thomas J. Labarère, José Chiquet, Christophe Diagnostics (Basel) Article We aimed to compare measurements from three of the most widely used software packages in the literature and to generate conversion algorithms for measurement of the central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) between SIVA and IVAN and between SIVA and VAMPIRE. We analyzed 223 retinal photographs from 133 human participants using both SIVA, VAMPIRE and IVAN independently for computing CRAE and CRVE. Agreement between measurements was assessed using Bland–Altman plots and intra-class correlation coefficients. A conversion algorithm between measurements was carried out using linear regression, and validated using bootstrapping and root-mean-square error. The agreement between VAMPIRE and IVAN was poor to moderate: The mean difference was 20.2 µm (95% limits of agreement, LOA, −12.2–52.6 µm) for CRAE and 21.0 µm (95% LOA, −17.5–59.5 µm) for CRVE. The agreement between VAMPIRE and SIVA was also poor to moderate: the mean difference was 36.6 µm (95% LOA, −12.8–60.4 µm) for CRAE, and 40.3 µm (95% LOA, 5.6–75.0 µm) for CRVE. The agreement between IVAN and SIVA was good to excellent: the mean difference was 16.4 µm (95% LOA, −4.25–37.0 µm) for CRAE, and 19.3 µm (95% LOA, 0.09–38.6 µm) for CRVE. We propose an algorithm converting IVAN and VAMPIRE measurements into SIVA-estimated measurements, which could be used to homogenize sets of vessel measurements obtained with different software packages. MDPI 2022-05-25 /pmc/articles/PMC9221842/ /pubmed/35741127 http://dx.doi.org/10.3390/diagnostics12061317 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mautuit, Thibaud
Cunnac, Pierre
Cheung, Carol Y.
Wong, Tien Y.
Hogg, Stephen
Trucco, Emanuele
Daien, Vincent
MacGillivray, Thomas J.
Labarère, José
Chiquet, Christophe
Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber
title Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber
title_full Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber
title_fullStr Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber
title_full_unstemmed Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber
title_short Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber
title_sort concordance between siva, ivan, and vampire software tools for semi-automated analysis of retinal vessel caliber
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9221842/
https://www.ncbi.nlm.nih.gov/pubmed/35741127
http://dx.doi.org/10.3390/diagnostics12061317
work_keys_str_mv AT mautuitthibaud concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT cunnacpierre concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT cheungcaroly concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT wongtieny concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT hoggstephen concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT truccoemanuele concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT daienvincent concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT macgillivraythomasj concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT labarerejose concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber
AT chiquetchristophe concordancebetweensivaivanandvampiresoftwaretoolsforsemiautomatedanalysisofretinalvesselcaliber