Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data

To evaluate whether the contrast-to-noise ratio (CNR) of an iodinated contrast agent in virtual monoenergetic images (VMI) from the first clinical photon-counting detector (PCD) CT scanner is superior to VMI CNR from a dual-source dual-energy CT scanner with energy-integrating detectors (EID), two a...

Descripción completa

Detalles Bibliográficos
Autores principales: Booij, Ronald, van der Werf, Niels R., Dijkshoorn, Marcel L., van der Lugt, Aad, van Straten, Marcel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9222007/
https://www.ncbi.nlm.nih.gov/pubmed/35741277
http://dx.doi.org/10.3390/diagnostics12061467
_version_ 1784732767090638848
author Booij, Ronald
van der Werf, Niels R.
Dijkshoorn, Marcel L.
van der Lugt, Aad
van Straten, Marcel
author_facet Booij, Ronald
van der Werf, Niels R.
Dijkshoorn, Marcel L.
van der Lugt, Aad
van Straten, Marcel
author_sort Booij, Ronald
collection PubMed
description To evaluate whether the contrast-to-noise ratio (CNR) of an iodinated contrast agent in virtual monoenergetic images (VMI) from the first clinical photon-counting detector (PCD) CT scanner is superior to VMI CNR from a dual-source dual-energy CT scanner with energy-integrating detectors (EID), two anthropomorphic phantoms in three different sizes (thorax and abdomen, QRM GmbH), in combination with a custom-built insert containing cavities filled with water, and water with 15 mg iodine/mL, were scanned on an EID-based scanner (Siemens SOMATOM Force) and on a PCD-based scanner (Siemens, NAEOTOM Alpha). VMI (range 40–100 keV) were reconstructed without an iterative reconstruction (IR) technique and with an IR strength of 60% for the EID technique (ADMIRE) and closest matching IR strengths of 50% and 75% for the PCD technique (QIR). CNR was defined as the difference in mean CT numbers of water, and water with iodine, divided by the root mean square value of the measured noise in water, and water with iodine. A two-sample t-test was performed to evaluate differences in CNR between images. A p-value < 0.05 was considered statistically significant. For VMI without IR and below 60 keV, the CNR of the PCD-based images at 120 and 90 kVp was up to 55% and 75% higher than the CNR of the EID-based images, respectively (p < 0.05). For VMI above 60 keV, CNRs of PCD-based images at both 120 and 90 kVp were up to 20% lower than the CNRs of EID-based images. Similar or improved performance of PCD-based images in comparison with EID-based images were observed for VMIs reconstructed with IR techniques. In conclusion, with PCD-CT, iodine CNR on low energy VMI (<60 keV) is better than with EID-CT.
format Online
Article
Text
id pubmed-9222007
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92220072022-06-24 Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data Booij, Ronald van der Werf, Niels R. Dijkshoorn, Marcel L. van der Lugt, Aad van Straten, Marcel Diagnostics (Basel) Article To evaluate whether the contrast-to-noise ratio (CNR) of an iodinated contrast agent in virtual monoenergetic images (VMI) from the first clinical photon-counting detector (PCD) CT scanner is superior to VMI CNR from a dual-source dual-energy CT scanner with energy-integrating detectors (EID), two anthropomorphic phantoms in three different sizes (thorax and abdomen, QRM GmbH), in combination with a custom-built insert containing cavities filled with water, and water with 15 mg iodine/mL, were scanned on an EID-based scanner (Siemens SOMATOM Force) and on a PCD-based scanner (Siemens, NAEOTOM Alpha). VMI (range 40–100 keV) were reconstructed without an iterative reconstruction (IR) technique and with an IR strength of 60% for the EID technique (ADMIRE) and closest matching IR strengths of 50% and 75% for the PCD technique (QIR). CNR was defined as the difference in mean CT numbers of water, and water with iodine, divided by the root mean square value of the measured noise in water, and water with iodine. A two-sample t-test was performed to evaluate differences in CNR between images. A p-value < 0.05 was considered statistically significant. For VMI without IR and below 60 keV, the CNR of the PCD-based images at 120 and 90 kVp was up to 55% and 75% higher than the CNR of the EID-based images, respectively (p < 0.05). For VMI above 60 keV, CNRs of PCD-based images at both 120 and 90 kVp were up to 20% lower than the CNRs of EID-based images. Similar or improved performance of PCD-based images in comparison with EID-based images were observed for VMIs reconstructed with IR techniques. In conclusion, with PCD-CT, iodine CNR on low energy VMI (<60 keV) is better than with EID-CT. MDPI 2022-06-14 /pmc/articles/PMC9222007/ /pubmed/35741277 http://dx.doi.org/10.3390/diagnostics12061467 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Booij, Ronald
van der Werf, Niels R.
Dijkshoorn, Marcel L.
van der Lugt, Aad
van Straten, Marcel
Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
title Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
title_full Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
title_fullStr Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
title_full_unstemmed Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
title_short Assessment of Iodine Contrast-To-Noise Ratio in Virtual Monoenergetic Images Reconstructed from Dual-Source Energy-Integrating CT and Photon-Counting CT Data
title_sort assessment of iodine contrast-to-noise ratio in virtual monoenergetic images reconstructed from dual-source energy-integrating ct and photon-counting ct data
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9222007/
https://www.ncbi.nlm.nih.gov/pubmed/35741277
http://dx.doi.org/10.3390/diagnostics12061467
work_keys_str_mv AT booijronald assessmentofiodinecontrasttonoiseratioinvirtualmonoenergeticimagesreconstructedfromdualsourceenergyintegratingctandphotoncountingctdata
AT vanderwerfnielsr assessmentofiodinecontrasttonoiseratioinvirtualmonoenergeticimagesreconstructedfromdualsourceenergyintegratingctandphotoncountingctdata
AT dijkshoornmarcell assessmentofiodinecontrasttonoiseratioinvirtualmonoenergeticimagesreconstructedfromdualsourceenergyintegratingctandphotoncountingctdata
AT vanderlugtaad assessmentofiodinecontrasttonoiseratioinvirtualmonoenergeticimagesreconstructedfromdualsourceenergyintegratingctandphotoncountingctdata
AT vanstratenmarcel assessmentofiodinecontrasttonoiseratioinvirtualmonoenergeticimagesreconstructedfromdualsourceenergyintegratingctandphotoncountingctdata