Cargando…
Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans
Background: Graf’s method is currently the most commonly used ultrasound-based technique for the diagnosis of developmental dysplasia of the hip (DDH). However, the efficiency and accuracy of diagnosis are highly affected by the sonographers’ qualification and the time and effort expended, which has...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9222165/ https://www.ncbi.nlm.nih.gov/pubmed/35741233 http://dx.doi.org/10.3390/diagnostics12061423 |
_version_ | 1784732806197280768 |
---|---|
author | Chen, Tao Zhang, Yuxiao Wang, Bo Wang, Jian Cui, Ligang He, Jingnan Cong, Longfei |
author_facet | Chen, Tao Zhang, Yuxiao Wang, Bo Wang, Jian Cui, Ligang He, Jingnan Cong, Longfei |
author_sort | Chen, Tao |
collection | PubMed |
description | Background: Graf’s method is currently the most commonly used ultrasound-based technique for the diagnosis of developmental dysplasia of the hip (DDH). However, the efficiency and accuracy of diagnosis are highly affected by the sonographers’ qualification and the time and effort expended, which has a significant intra- and inter-observer variability. Methods: Aiming to minimize the manual intervention in the diagnosis process, we developed a deep learning-based computer-aided framework for the DDH diagnosis, which can perform fully automated standard plane detection and angle measurement for Graf type I and type II hips. The proposed framework is composed of three modules: an anatomical structure detection module, a standard plane scoring module, and an angle measurement module. This framework can be applied to two common clinical scenarios. The first is the static mode, measurement and classification are performed directly based on the given standard plane. The second is the dynamic mode, where a standard plane from ultrasound video is first determined, and measurement and classification are then completed. To the best of our knowledge, our proposed framework is the first CAD method that can automatically perform the entire measurement process of Graf’s method. Results: In our experiments, 1051 US images and 289 US videos of Graf type I and type II hips were used to evaluate the performance of the proposed framework. In static mode, the mean absolute error of α, β angles are 1.71° and 2.40°, and the classification accuracy is 94.71%. In dynamic mode, the mean absolute error of α, β angles are 1.97° and 2.53°, the classification accuracy is 89.51%, and the running speed is 31 fps. Conclusions: Experimental results demonstrate that our fully automated framework can accurately perform standard plane detection and angle measurement of an infant’s hip at a fast speed, showing great potential for clinical application. |
format | Online Article Text |
id | pubmed-9222165 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-92221652022-06-24 Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans Chen, Tao Zhang, Yuxiao Wang, Bo Wang, Jian Cui, Ligang He, Jingnan Cong, Longfei Diagnostics (Basel) Article Background: Graf’s method is currently the most commonly used ultrasound-based technique for the diagnosis of developmental dysplasia of the hip (DDH). However, the efficiency and accuracy of diagnosis are highly affected by the sonographers’ qualification and the time and effort expended, which has a significant intra- and inter-observer variability. Methods: Aiming to minimize the manual intervention in the diagnosis process, we developed a deep learning-based computer-aided framework for the DDH diagnosis, which can perform fully automated standard plane detection and angle measurement for Graf type I and type II hips. The proposed framework is composed of three modules: an anatomical structure detection module, a standard plane scoring module, and an angle measurement module. This framework can be applied to two common clinical scenarios. The first is the static mode, measurement and classification are performed directly based on the given standard plane. The second is the dynamic mode, where a standard plane from ultrasound video is first determined, and measurement and classification are then completed. To the best of our knowledge, our proposed framework is the first CAD method that can automatically perform the entire measurement process of Graf’s method. Results: In our experiments, 1051 US images and 289 US videos of Graf type I and type II hips were used to evaluate the performance of the proposed framework. In static mode, the mean absolute error of α, β angles are 1.71° and 2.40°, and the classification accuracy is 94.71%. In dynamic mode, the mean absolute error of α, β angles are 1.97° and 2.53°, the classification accuracy is 89.51%, and the running speed is 31 fps. Conclusions: Experimental results demonstrate that our fully automated framework can accurately perform standard plane detection and angle measurement of an infant’s hip at a fast speed, showing great potential for clinical application. MDPI 2022-06-09 /pmc/articles/PMC9222165/ /pubmed/35741233 http://dx.doi.org/10.3390/diagnostics12061423 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chen, Tao Zhang, Yuxiao Wang, Bo Wang, Jian Cui, Ligang He, Jingnan Cong, Longfei Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans |
title | Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans |
title_full | Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans |
title_fullStr | Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans |
title_full_unstemmed | Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans |
title_short | Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans |
title_sort | development of a fully automated graf standard plane and angle evaluation method for infant hip ultrasound scans |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9222165/ https://www.ncbi.nlm.nih.gov/pubmed/35741233 http://dx.doi.org/10.3390/diagnostics12061423 |
work_keys_str_mv | AT chentao developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans AT zhangyuxiao developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans AT wangbo developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans AT wangjian developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans AT cuiligang developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans AT hejingnan developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans AT conglongfei developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans |