Cargando…

Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans

Background: Graf’s method is currently the most commonly used ultrasound-based technique for the diagnosis of developmental dysplasia of the hip (DDH). However, the efficiency and accuracy of diagnosis are highly affected by the sonographers’ qualification and the time and effort expended, which has...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Tao, Zhang, Yuxiao, Wang, Bo, Wang, Jian, Cui, Ligang, He, Jingnan, Cong, Longfei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9222165/
https://www.ncbi.nlm.nih.gov/pubmed/35741233
http://dx.doi.org/10.3390/diagnostics12061423
_version_ 1784732806197280768
author Chen, Tao
Zhang, Yuxiao
Wang, Bo
Wang, Jian
Cui, Ligang
He, Jingnan
Cong, Longfei
author_facet Chen, Tao
Zhang, Yuxiao
Wang, Bo
Wang, Jian
Cui, Ligang
He, Jingnan
Cong, Longfei
author_sort Chen, Tao
collection PubMed
description Background: Graf’s method is currently the most commonly used ultrasound-based technique for the diagnosis of developmental dysplasia of the hip (DDH). However, the efficiency and accuracy of diagnosis are highly affected by the sonographers’ qualification and the time and effort expended, which has a significant intra- and inter-observer variability. Methods: Aiming to minimize the manual intervention in the diagnosis process, we developed a deep learning-based computer-aided framework for the DDH diagnosis, which can perform fully automated standard plane detection and angle measurement for Graf type I and type II hips. The proposed framework is composed of three modules: an anatomical structure detection module, a standard plane scoring module, and an angle measurement module. This framework can be applied to two common clinical scenarios. The first is the static mode, measurement and classification are performed directly based on the given standard plane. The second is the dynamic mode, where a standard plane from ultrasound video is first determined, and measurement and classification are then completed. To the best of our knowledge, our proposed framework is the first CAD method that can automatically perform the entire measurement process of Graf’s method. Results: In our experiments, 1051 US images and 289 US videos of Graf type I and type II hips were used to evaluate the performance of the proposed framework. In static mode, the mean absolute error of α, β angles are 1.71° and 2.40°, and the classification accuracy is 94.71%. In dynamic mode, the mean absolute error of α, β angles are 1.97° and 2.53°, the classification accuracy is 89.51%, and the running speed is 31 fps. Conclusions: Experimental results demonstrate that our fully automated framework can accurately perform standard plane detection and angle measurement of an infant’s hip at a fast speed, showing great potential for clinical application.
format Online
Article
Text
id pubmed-9222165
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92221652022-06-24 Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans Chen, Tao Zhang, Yuxiao Wang, Bo Wang, Jian Cui, Ligang He, Jingnan Cong, Longfei Diagnostics (Basel) Article Background: Graf’s method is currently the most commonly used ultrasound-based technique for the diagnosis of developmental dysplasia of the hip (DDH). However, the efficiency and accuracy of diagnosis are highly affected by the sonographers’ qualification and the time and effort expended, which has a significant intra- and inter-observer variability. Methods: Aiming to minimize the manual intervention in the diagnosis process, we developed a deep learning-based computer-aided framework for the DDH diagnosis, which can perform fully automated standard plane detection and angle measurement for Graf type I and type II hips. The proposed framework is composed of three modules: an anatomical structure detection module, a standard plane scoring module, and an angle measurement module. This framework can be applied to two common clinical scenarios. The first is the static mode, measurement and classification are performed directly based on the given standard plane. The second is the dynamic mode, where a standard plane from ultrasound video is first determined, and measurement and classification are then completed. To the best of our knowledge, our proposed framework is the first CAD method that can automatically perform the entire measurement process of Graf’s method. Results: In our experiments, 1051 US images and 289 US videos of Graf type I and type II hips were used to evaluate the performance of the proposed framework. In static mode, the mean absolute error of α, β angles are 1.71° and 2.40°, and the classification accuracy is 94.71%. In dynamic mode, the mean absolute error of α, β angles are 1.97° and 2.53°, the classification accuracy is 89.51%, and the running speed is 31 fps. Conclusions: Experimental results demonstrate that our fully automated framework can accurately perform standard plane detection and angle measurement of an infant’s hip at a fast speed, showing great potential for clinical application. MDPI 2022-06-09 /pmc/articles/PMC9222165/ /pubmed/35741233 http://dx.doi.org/10.3390/diagnostics12061423 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Tao
Zhang, Yuxiao
Wang, Bo
Wang, Jian
Cui, Ligang
He, Jingnan
Cong, Longfei
Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans
title Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans
title_full Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans
title_fullStr Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans
title_full_unstemmed Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans
title_short Development of a Fully Automated Graf Standard Plane and Angle Evaluation Method for Infant Hip Ultrasound Scans
title_sort development of a fully automated graf standard plane and angle evaluation method for infant hip ultrasound scans
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9222165/
https://www.ncbi.nlm.nih.gov/pubmed/35741233
http://dx.doi.org/10.3390/diagnostics12061423
work_keys_str_mv AT chentao developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans
AT zhangyuxiao developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans
AT wangbo developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans
AT wangjian developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans
AT cuiligang developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans
AT hejingnan developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans
AT conglongfei developmentofafullyautomatedgrafstandardplaneandangleevaluationmethodforinfanthipultrasoundscans