Cargando…

Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection

In addition to their use as an additive to improve physical properties of solvent polymeric membranes, plasticizers have a considerable impact on the specificity and sensitivity of membrane-modified electrochemical sensors. In this work, we aim at the hybridization of two different plasticizers usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruangsuj, Pattarawan, Wanthongcharoen, Suwanan, Chaisriratanakul, Woraphan, Bunjongpru, Win, Yamprayoonswat, Wariya, Jeamsaksiri, Wutthinan, Jumpathong, Watthanachai, Yasawong, Montri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9223680/
https://www.ncbi.nlm.nih.gov/pubmed/35742849
http://dx.doi.org/10.3390/ijms23126402
_version_ 1784733184474218496
author Ruangsuj, Pattarawan
Wanthongcharoen, Suwanan
Chaisriratanakul, Woraphan
Bunjongpru, Win
Yamprayoonswat, Wariya
Jeamsaksiri, Wutthinan
Jumpathong, Watthanachai
Yasawong, Montri
author_facet Ruangsuj, Pattarawan
Wanthongcharoen, Suwanan
Chaisriratanakul, Woraphan
Bunjongpru, Win
Yamprayoonswat, Wariya
Jeamsaksiri, Wutthinan
Jumpathong, Watthanachai
Yasawong, Montri
author_sort Ruangsuj, Pattarawan
collection PubMed
description In addition to their use as an additive to improve physical properties of solvent polymeric membranes, plasticizers have a considerable impact on the specificity and sensitivity of membrane-modified electrochemical sensors. In this work, we aim at the hybridization of two different plasticizers using the electropolymerization technique in the development of a cadmium(II)-selective electrochemical sensor based on screen-printed gold electrode along with cyclic voltammetric measurement. At this point, we first screen for the primary plasticizer yielding the highest signal using cyclic voltammetry followed by pairing it with the secondary plasticizers giving rise to the most sensitive current response. The results show that the hybridization of DOS and TOTM with 3:1 weight ratio (~137.7-μm-thick membrane) renders a signal that is >26% higher than that from the sensor plasticized by DOS per se in water. The solution of 0.1 mM hydrochloric acid (pH 4) is the optimal supporting electrolyte. In addition, hybrid plasticizers have adequate redox capacity to induce cadmium(II) transfer from bulk solution to the membrane/water interfaces. Conversion of voltammetric signals to semi-integral currents results in linearity with cadmium(II) concentration, indicating the irreversible cadmium(II) transfer to the membrane. The DOS:TOTM hybrid sensor also exhibits high sensitivity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 95 ppb and 288 ppb, respectively, as well as greater specificity towards cadmium(II) than that obtained from the single plasticizer sensor. Furthermore, recovery rates of spiked cadmium(II) in water samples were higher than 97% using the hybrid plasticizer sensor. Unprecedentedly, our work reports that the hybridization of plasticizers serves as ion-to-electron transducer that can improve the sensor performance in cadmium(II) detection.
format Online
Article
Text
id pubmed-9223680
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-92236802022-06-24 Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection Ruangsuj, Pattarawan Wanthongcharoen, Suwanan Chaisriratanakul, Woraphan Bunjongpru, Win Yamprayoonswat, Wariya Jeamsaksiri, Wutthinan Jumpathong, Watthanachai Yasawong, Montri Int J Mol Sci Article In addition to their use as an additive to improve physical properties of solvent polymeric membranes, plasticizers have a considerable impact on the specificity and sensitivity of membrane-modified electrochemical sensors. In this work, we aim at the hybridization of two different plasticizers using the electropolymerization technique in the development of a cadmium(II)-selective electrochemical sensor based on screen-printed gold electrode along with cyclic voltammetric measurement. At this point, we first screen for the primary plasticizer yielding the highest signal using cyclic voltammetry followed by pairing it with the secondary plasticizers giving rise to the most sensitive current response. The results show that the hybridization of DOS and TOTM with 3:1 weight ratio (~137.7-μm-thick membrane) renders a signal that is >26% higher than that from the sensor plasticized by DOS per se in water. The solution of 0.1 mM hydrochloric acid (pH 4) is the optimal supporting electrolyte. In addition, hybrid plasticizers have adequate redox capacity to induce cadmium(II) transfer from bulk solution to the membrane/water interfaces. Conversion of voltammetric signals to semi-integral currents results in linearity with cadmium(II) concentration, indicating the irreversible cadmium(II) transfer to the membrane. The DOS:TOTM hybrid sensor also exhibits high sensitivity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 95 ppb and 288 ppb, respectively, as well as greater specificity towards cadmium(II) than that obtained from the single plasticizer sensor. Furthermore, recovery rates of spiked cadmium(II) in water samples were higher than 97% using the hybrid plasticizer sensor. Unprecedentedly, our work reports that the hybridization of plasticizers serves as ion-to-electron transducer that can improve the sensor performance in cadmium(II) detection. MDPI 2022-06-08 /pmc/articles/PMC9223680/ /pubmed/35742849 http://dx.doi.org/10.3390/ijms23126402 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ruangsuj, Pattarawan
Wanthongcharoen, Suwanan
Chaisriratanakul, Woraphan
Bunjongpru, Win
Yamprayoonswat, Wariya
Jeamsaksiri, Wutthinan
Jumpathong, Watthanachai
Yasawong, Montri
Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection
title Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection
title_full Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection
title_fullStr Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection
title_full_unstemmed Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection
title_short Hybrid Plasticizers Enhance Specificity and Sensitivity of an Electrochemical-Based Sensor for Cadmium Detection
title_sort hybrid plasticizers enhance specificity and sensitivity of an electrochemical-based sensor for cadmium detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9223680/
https://www.ncbi.nlm.nih.gov/pubmed/35742849
http://dx.doi.org/10.3390/ijms23126402
work_keys_str_mv AT ruangsujpattarawan hybridplasticizersenhancespecificityandsensitivityofanelectrochemicalbasedsensorforcadmiumdetection
AT wanthongcharoensuwanan hybridplasticizersenhancespecificityandsensitivityofanelectrochemicalbasedsensorforcadmiumdetection
AT chaisriratanakulworaphan hybridplasticizersenhancespecificityandsensitivityofanelectrochemicalbasedsensorforcadmiumdetection
AT bunjongpruwin hybridplasticizersenhancespecificityandsensitivityofanelectrochemicalbasedsensorforcadmiumdetection
AT yamprayoonswatwariya hybridplasticizersenhancespecificityandsensitivityofanelectrochemicalbasedsensorforcadmiumdetection
AT jeamsaksiriwutthinan hybridplasticizersenhancespecificityandsensitivityofanelectrochemicalbasedsensorforcadmiumdetection
AT jumpathongwatthanachai hybridplasticizersenhancespecificityandsensitivityofanelectrochemicalbasedsensorforcadmiumdetection
AT yasawongmontri hybridplasticizersenhancespecificityandsensitivityofanelectrochemicalbasedsensorforcadmiumdetection